Site and Soil Evaluation

of 13

Page text shows just the words. Original shows the document exactly as it was published.

Indicative Permeability

          Test Site:                   1                      2                      3
        Soil Category                  5                      5                      5
          Structure                Moderate               Moderate               Moderate
   Indicative Permeability         0.06-0.12              0.06-0.12              0.06-0.12
             DIR                       3                      3                      3



The following design criteria is applicable for the following disposal methods: Cottage

                                                      1                  2                   3
              Fall                    (mm)           25                 25                   25
              Time                   (mins)          62                 58                   300
                                     (secs)          54                 19                    0
   Indicative Permeability           (Ksat)        0.0636              0.0686           0.0133
        Soil Category                               5                    5                5
            Structure                            Moderate             Moderate         Moderate


Indicative Permeability

          Test Site:                   1                      2                      3
        Soil Category                  5                      5                      5
          Structure                Moderate               Moderate               Moderate
   Indicative Permeability         0.06-0.12              0.06-0.12              0.06-0.12
             DIR                       3                      3                      3


Recommendations:

Based upon our Site and Soil Assessments we recommend the following method of On-Site Effluent Disposal
should be used.

For the treatment of the Effluent we recommend;


      Advanced Secondary WasteWater Treatment System (AWTS)
(NOTE: The system chosen must satisfy both the Queensland Plumbing and Wastewater Code and AS 1547-2012
On-Site Domestic Waste Water Code and be approved for use by the Local Shire/Council governing the allotment.)

For the disposal of the treated effluent within the Land Application Area we recommend;

      A Pressurised Sub-Surface Reticulated Irrigation System




   AUSTRALIAN SOIL INVESTIGATIONS                               4                                  ASI Ref: 220144(A)
Log in to download the original file

Site and Soil Evaluation.pdf · 2.6 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.