Original source · versioned page text
Site and Soil Evaluation
Indicative Permeability
Test Site: 1 2 3
Soil Category 5 5 5
Structure Moderate Moderate Moderate
Indicative Permeability 0.06-0.12 0.06-0.12 0.06-0.12
DIR 3 3 3
The following design criteria is applicable for the following disposal methods: Cottage
1 2 3
Fall (mm) 25 25 25
Time (mins) 62 58 300
(secs) 54 19 0
Indicative Permeability (Ksat) 0.0636 0.0686 0.0133
Soil Category 5 5 5
Structure Moderate Moderate Moderate
Indicative Permeability
Test Site: 1 2 3
Soil Category 5 5 5
Structure Moderate Moderate Moderate
Indicative Permeability 0.06-0.12 0.06-0.12 0.06-0.12
DIR 3 3 3
Recommendations:
Based upon our Site and Soil Assessments we recommend the following method of On-Site Effluent Disposal
should be used.
For the treatment of the Effluent we recommend;
Advanced Secondary WasteWater Treatment System (AWTS)
(NOTE: The system chosen must satisfy both the Queensland Plumbing and Wastewater Code and AS 1547-2012
On-Site Domestic Waste Water Code and be approved for use by the Local Shire/Council governing the allotment.)
For the disposal of the treated effluent within the Land Application Area we recommend;
A Pressurised Sub-Surface Reticulated Irrigation System
AUSTRALIAN SOIL INVESTIGATIONS 4 ASI Ref: 220144(A)