Original source · versioned page text
135 Lake Weyba Rd Earthworks Certification L1
NATA accredited facility no: 20084 PO Box 1225, Nambour QLD 4560 COA Lanoretory Mob 0429 674 334 a NATA WwW ACCREDITED 702 TECHI COMPETE Accrectieg for compliance with ISONEC 17025 - Testng For All Civil Testing AB.N. 21 61 339 7934 Servicing South East Queensiand 6 Mill Lane, Nambour Test Report CQA eee Accredited for compres with ISOEC 17025 ~ = testing Project:_135 Lake Weyba Dr Requested By:_O/N Noosaville Date: 20-9-22 Client: Andres Gabarrin Report No. _ 1210 Field Test Procedure: AS1289 5.3.1 soils compaction and density tests-determination of the field density of a soil-sand replacement method using a sand-cone pouring apparatus, AS1289 .1.2.1 Sampling and preparation of soils-disturbed samples-standard method (6.4) Sampling from layers in earthworks or pavements(b) compacted Laboratory Test Procedure AS1289 5.4.1 Soil compaction and density tests-compaction control test-dry density ratio, moisture variation and moisture ratio, AS1289 5.1.1 (Soil compaction and density tests-determination of the dry density/moisture content of a soil using standard compactive effort), AS1289 2.1.1 moisture content tests- determination of the moisture content of a soil-oven drying method(standard method). Over size sieve used (mm): 19.0 Was OMC & MDD assigned: No Was assignment values used: No Was the sample taken prior to compaction: No Curing Time:- 24 Liquid limit determination: visual tactile assessment Soil Description & Soil Layer thickness (m): Allotment Fill +0.5m COMPACTION SPECIFICATION: 95% Standard Compaction TEST RESULTS Laboratory Number 1210.6 1210.7 Location Lot2 Lot2 Approx. See Site Plan See Site Plan Elevation/layer depth Approx. +2.5m F/L Hole Depth (mm) 125 129 FIELD & LABORATORY DATA Compacted Field Dry density (t/m3) 155 1.56 (nearest 0.01) Field Moisture Content (%) 14.0 14.5 (nearest 0.5) Mat. retained on oversize sieve (%) 0.0 0.0 Dry (nearest 1) Mat. retained on oversize sieve (%) 0.0 0.0 Wet (nearest 1) Max. Dry Density (t/m3) 1.58 1.59 nearest 0.01) Adjusted Max. Dry Density (t/m3) na na ‘nearest 0.01) Adjusted Max, Dry Density Laboratory n/a wa reference number Optimum Moisture Content (%) 15.5 14.5 (nearest 0.5) Moisture Ratio (%) 91.0 101.5 (nearest 0.5) Variation of Optimum Moisture Content | -1.Sdry 0.0 (%) Density Ratio (%) Spear 97.5 98.0 Page 2 of 5 Tests and sampling results relate only to the items tested or sampled. results applies to the sample received/( abnormalities may contribute to the report being compromised) Reports shall not be reproduced except in full ot _: NATA Accredited Facility No. :- 20084 eC at WF ABN 21 61339 7934 CQA Laboratory Approved Person: 6 Mill Lane Nambour C. Templeton Form R18 June 2021 Date: 28-2-23
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original