4.0 Planning assessment

4.1 Technical Compliance
The proposed multiple dwelling meet the relevant key technical provisions of the High Density
Residential and Multiple Dwellings Codes, as described below, with further discussion provided
against the relevant Performance Outcome thereafter.

 Criteria         The Noosa Plan 2020                    Proposal                        Compliance
 Site Details     3 Henderson St, Sunshine Beach – 602m2
 Height           12m                                    12.5m                           PO
                  3 storeys                              3 storeys                       Y – backfilled around
                                                                                         western elevation
 Site Cover       40% (240.8m2)                               39.5% (238m2)              Y
 GFA              0.65:1 (391.3m2)                            0.65:1 (391.3m2)           Y
 Private   Open   Ground Level (20m2) small dwelling unit 3   Unit 1 = >9m2              Y
 Space            Above Ground (9m2)                          Unit 2 = >9m2              Y
                                                              Unit 3 = 20m²              Y
 Setbacks         Frontage
                  6m - Architectural feature wall             6.0m                       Y - on lower levels and
                                                                                         PO on 3rd storey
                  Basement                                    6.1m                       Y
                  - 1st and 2nd storey (6m)                   6.1m                       Y
                  - 3rd storey (10m)                          6.9m                       PO
                  Side
                  - north (1.5m – 2.5m)                       2m – 3m                    PO
                  - south (1.5m – 2.5m)                       0m – 2.4m                  PO
                  Rear
                  - Basement (6m)                             6m                         Y
                  - 1st and 2nd storey (6m)                   7.5m to eave and 8.1m      Y
                                                              to building
                  - 3rd storey (8m)                           7.5m to eave and 8.1m      PO
                                                              to building
 Landscaping      Front 6m landscaping with pools and         Parking        setback     Y
                  visitor carparking setback 2m               minimum 2.2m

                  40% (240.8m²) landscaping with
                  60% (144.5m²) of this to be soft            40.1% (242m2)              Y
                  landscaping                                 >60% - 83% (200m²)         Y
 Carparking       6 spaces                                    8 spaces                   Y
                  Unit 1 = 2 spaces
                  Unit 2 = 2 spaces
                  Unit 3 = 1 space
                  Visitor = 1 per 4 units
 Earthworks       Cut or fill less than 1.5m                  Cut      for   basement    PO
                                                              greater than 1.5m
 Waste Storage    Screened waste areas and located for        Bin storage screened by    Y
                  transport to kerb with grade of <1:15       landscaping.
 Roof Form        No rooftop terraces and parapets do not     Rooftop terrace            PO
                  exceed 50% of the front façade              No parapets                Y
 Fencing          Setback an avg of 1m and articulated by     Fencing setback 1m for     Can be conditioned to
                  stepping the design.                        9m of the 14m frontage.    comply.
                                                              Landscaping       to  be
                                                              provided in front of the
                                                              wall for screening.




                                                                                                      Page 6 of 13

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

planning report henderson st units.pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.