Skip to the record
For the highest quality transcripts.

Council archive · source document

09/0363 - Response to Information Request [As Published] · 132009.363

of 2

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

16 October 2009
SCG Ref: 19239(L1)

coed .
ros oer ara .

Agenti Architects
2/20 Nairana Rest
Noosa Heads Q 4567

Dear Sirs

 

Re: 21 Attunga Heights, Noosa Heads
We refer to councils’ recent information request dated 7 October 2009 and comment as follows.

The vehicle sweep paths indicated on our drawing 19239-C2 clearly indicate adequate movement
in and out of the garages. The exact position of the garage doors albeit not shown on our plan will
still allow for the vehicle movements to occur. The dark line indicating the centre dividing wall on our
plan is depicting the upper floor extent of the wall and as such will not encroach onto the driveway
as shown on our plan. Regardless of these points we have amended our drawing 19239-C2 and
enclose copies for councils approval.

We have included a longitudinal section of the driveway on the enclosed revised drawing. We have
also included some proposed spot surface levels along the length of the driveway in particular along
its northern edge adjacent the northern boundary. The excavated slope adjacent this boundary will
be in the order of 45° which we are satisfied with. The proposed driveway profile will clearly drain to
the nominated grated pit at the end of the driveway towards the rear of the property.

From our driveway centre line it can be seen that the proposed surface level at the boundary line
will be in the order of 62.3m which is approximately 450mm below existing surface levels as
indicated by the contours. The crossfall across the driveway will be marginal, therefore reducing the
depth of cut required along the northern alignment of the driveway to less than 300mm.

Finally, the alignment of the outlet drains from the proposed water tanks are indicative in where they
connect f\the kerb and channel. There is an additional 750mm of fall if required, to the northern
side of fhe/ proposed driveway alignment. The detailed stormwater design will be included in the
buildingjapplication stage.

   

Yours,

SEAN SHARP-RICHARDSON — RPEQ 5835
For and on behalf of
SCG CONSULTING ENGINEERS

Enc

Pp 075455 5604

f 075455 5696

e [email protected]

Ww scg-engineers.com

po box 1661 noosa heads qld 4567
1/11 project ave noosaville qld 4566

Debuild Pty Ltd Trading as
STRUCTURAL * CIVIL «GEOTECHNICAL ABN 40 098 481 899
Full text of the other 1 page

Page 2

 

 

‘ Revision | Description Date

 

 

 

DRAWING SIZE — A2 A Oriveway long section and levels included. 16.10.09
~

 

 

 

 

 

SPRAYED RC FACING TO

Ko EXCAVATED FACE REFER 10
25.468, .

             
 

 

 

 

 

 

          

ORIVEWAY CROSS OVER DETALS
TO 8€ BY ACCORDANCE WITH
SUNSHINE COAST REGIONAL
COUNCH'S STD DRAWINGS.

 

 

 

SPRAYED 25MPa

: CONCRETE FACING
SL72 MESH MIDDLE

 

 

 

 

 

 

SATURATE GROUND ADJACENT
EXCAVATION] FOR A MINIMUM OF
24 HOURS PRIOR TO WORKS
COMMENCING,

 

 

 

 

 

29 OCT 2069

SCRC - Tewantin
Front Counter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND
CONSTRUCTION NOTES:
_.-:77 INDICATES EXISTING SURFACE GENERAL:
48° CONTOUR AND ‘LEVEL TO AHD. |, Do not scale from this drawing,

2. All dimensions in millimetres
| 3 Setting out dmensions are to be obtained fram the architectural

crowings.
om srelrealw oa SPOTS cin en vind tn ep

 

 

SPRAYED RC FACING TO are to be referred to the engineer immediately.
EXCAVATED FACE REFER 10 KS 5. The builder is responsible for locating all existing services within and

SITE PLAN DETAIL ~ EXISTING sunset SPOT LEVELS. adjocent the afiotment and shail ensure thot ali new works ore in

 

 

accordance with Une attached critical depth ine diagram,
(Scale 1:100) FOOTPATHS AND DRIVEWAYS:
: = 450Sq GRATED FIELD INLETS, \ aes ee sant von prior ror femon
ngs ore not desi commercial vehicles
PRE-CAST CONCRETE. 3 Concrete drivenay to be 125mm thk. excuding any finkshed treatments,
9. stamping
{ 4. Concrete surtoce tolerance +5.0mm over 3.0m
5. Concrete N25 In occordance with AS 1379 ond AS 3600
4 8, Reinforcement fabric to AS 1304, placed central slob depth,
. 7, Expansion pints to be 10mm wide wet tooled with every 2nd mesh wire
ext glong joint.
8. One access point permitted for each alotment.
9, For curved drivewoys, maximum grades apply to inside edge of cure
‘ed 08

 

 

60.60
60.70
61.20
61.69
6218
62.2

6233
6225

DESO

 

10. All services to be locoted and protected os required priot to work
commencing

 

247
29
16.8
12.4
80
60
4.0
00
TNE

 

 

'ssue: ISSUE FOR CONST.

 

CLEROT

CONSULTING « ENGINEERS
SCG siveelural - civil - geotechnical

ABN 40 098 481 899

P
Kerb_ Line Nominal

 

 

eee Te . U1/11 PROJECT AVENUE, NOOSAVILLE QLD.4566
Ph (07) 5455 5604 Fax (07) 5455 5696

 

 

 

 

 

 

 

 

 

 

 

 

 

 

, Title: EARTHWORKS AND TURNING CIRCLES.

 

Project 21 Attunga Heights
Noosa Heads.

 

 

 

 

 

Date: August 2009. | Drg No. 19239-C2 | & A

 

 

 

 

Used in these records

About this file

File size
206 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

09_0363 - Response to Information Request [As Published].pdf · 206 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.