Original PDF page 50, section 1. The text section number identifies this passage in the reader.

                                                                                               ~
                                                                                          Callaghan & Toth

                            Replace geotextile where used, check and if necessary replace sand media with
                            coarser sand. Check that slottedpipe is not blocked and outlet free draining.
                            Replace and repair where necessary.
                            Erosion should be repaired and investigate measures to reduce erosion e.g.
                            install rock spalls upstream of the erosion so as to dissipate the flow across a
                            broad area.

                            Dominating weeds should be removed by hand and taken to the Council’s Refuse
                            Centre.


                                                Operational Phase

Objective                   The Owner is to include the Bioretention systems into their maintenance
                            program.




Actions                     Inspect Bioretention systems every six months to determine maintenance
                            requirements.
                            Undertake general maintenance such as:

                                ~     Remove accumulated litter / debris

                                ~     Remove accumulated sediments

                                ~     Remove weeds and dead plants

                                ~     Replace plants where necessary
                                ~     Water plants if necessary

                                ~     Control erosion and sediment loss upstream or within system where
                                      necessary.

                            Routine clean outs of Bioretention Systems should be planned on a ten-yearly
                            basis.


Monitoring                  The Owners Landscape Gardener will carry out six monthly inspections of the
                            Bioretention Systems. The following will be examined at each inspection:

                                ~     Sediment build up on the surface under the river stones

                                ~     Health of vegetation

                                ~     Pond age during major storms not infiltrating into the sand

                                ~     Erosion at the outlet

                                ~     Pondage during minor storms


Reporting                   Inspection Records are to be logged and kept for verification of compliance on a
                            need basis.

                            Records of any maintenance are to be logged and kept on site.

                            Records of environmental incidents and corrective actions should be kept on site
                            and Council notified of any problems.


Incidents                   Sediment builds up on the surface.

                            The vegetation dies off.

                            Pondage of water is in excess of one hour.
                            Excessive erosion occurs within the system.




                                                                                                               B

1209 Animal Husbandry   Top Forestry Rd, Ridgewood
                        -
                                                                                                SWQMP
April 2013
Log in to download the original file

Response to Information Request - MCU12_0184.pdf · 122 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.