                                                       accommodate a dwelling and ancillary buildings
                                                       and use areas;
                                                       c) for lots less than 2,500m2, maximise
                                                       separation of buildings from hazardous
                                                       vegetation.

                                                       513.2 Residential lots are designed so that their
                                                       size and shape allow for efficient emergency
                                                       access to   buildings for fire fighting appliances



    Table 13.10 Flood Hazard Areas


                        Column 1                                             Column 2

                   Specific Outcomes                                     Probable Solutions

    13.38 Effects of use and subdivision
    5afety and floodplain function
    014 The proposed use does not compromise the       Not applicable. The proposed lots do not fall

    safety of people or property from floods up to     under the Flood Hazard Area.
    and including a 1% AEP (1:100year ARI )flood
    event.

    Hazardous materials
    016 Public safety and the environment are not      516.1 Hazardous materials are not

    adversely affected by the detrimental impacts of   manufactured and stored on the site.
    floodwater on hazardous materials
    manufactured or stored in bulk.


    Infrastructure
    017Sewerage treatment plants maintain their        517.1 Components of the sewerage treatment
    function during flood events up to a 1% AEP        plants that are likely to fail or may result in
    1:100 year ARI) flood event.                       contamination are-

                                                       a) located above the level of a 1% AEP (1:100
                                                       ARI) flood event; or
                                                       b) are designed and constructed to exclude
                                                       water inundation or infiltration and resist

                                                       hydrostatic and hydrodynamic forces as a result
                                                       of inundation.


    018 Community Uses and Infrastructure Uses         518.1 Community Uses and Infrastructure Uses
    are able to function effectively during and        are sited and constructed to ensure that floor

    immediately after flood events.                    levels are not less than the AEP (or ARI )levels
                                                       identified below-
                                                       a) Emergency service facilities- 0.2% AEP (1:500
                                                       ARI);
                                                       b) Emergency shelter- 0.5% AEP (1:200ARt);
                                                       c) Police station- 0.5% AEP (1:200ARI);
                                                       d) Hospital- 0.2% AEP (1:500ARI);
                                                       e) Electricity substation- 0.2% AEP (1:500ARI);
                                                       f) Water treatment plant- 0.2% AEP (1:500ARI);
                                                       g) Power station- 0.5% AEP (1:200ARI);
                                                       h) Major electrical switch yard- 0.5% AEP (1:200
Log in to download the original file

Development Application part 2 of 2 Plans and reports REC13_0094.pdf · 17.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.