Original source · versioned page text
2019-12-11 SM Agenda - Item 1 - Attachment 4 - Final New Noosa Plan Part 8-9 Schedule Appendix Track Change version
The original of this document is very large (14.9 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn Performance outcomes Acceptable Outcomes
service area, an adequate, reliable, safely located and freely (a) an accessible dam, swimming pool or water tank
accessible water supply is provided for fire fighting purposes, available for firefighting purposes with an onsite water
which is in addition to day to day water supply. volume of not less than 5,000 litres; and
(b) a water supply outlet pipe 50 millimetres in diameter and
fitted with a standard fire brigade fitting connected to the
water supply (other than where the water supply is in a
swimming pool or dam).
Editor’s Note — Water supply capacity for firefighting purposes
is in addition to water supply capacity for household use.
Flood Hazard Area
PO16 AO16.1
Where located in the Flood Hazard Area as shown on Flood TheWhere the development is located in the Flood Hazard Area
Hazard Overlay Map in Schedule the developmentDevelopment as shown on Flood Hazard Overlay Map in Schedule 2,
is designed and sited to ensure risk to people and property the finished floor level of habitable rooms is at least 300
from flooding is avoided or minimised. millimetres above the Defined flood event (DFE);
OR
AO16.2
Where the DFE has not been modelled for the area, the
finished floor level of habitable rooms is at least
500 millimetres above the highest recorded flood.
Editor's noteNote—The QDC mandatory provisions MP3.5 also
apply to the construction of buildings in flood hazard areas.
PO17
Underground car parking areas are designed to drain and No acceptable outcome provided
function safely during a flood event and power failure.
Editor's note—Basements should have flood immunity above
the 1%AEP defined flood event with alternative means to
mechanical pumping used to achieve such immunity.
Major Electricity Infrastructure & Substations
PO18 AO18.1
Development is sufficiently separated from major electricity Development including any sensitive land uses is at least:
infrastructure and substations to minimise the likelihood of 50 metres from a transmission substation;
(a)
nuisance or complaint.
(b) 10 metres from any other substation; and
(c) 30 metres from a transmission line easement.
AO18.2
Habitable buildings are not located within an easement for a
distribution line.
PO19 AO19
Development is located and designed to avoid or minimise Noise emissions do not exceed 5db(A) above background
noise nuisance from the use of infrastructure. noise level internal to a habitable building measured in
accordance with AS1055.
PO20 AO20
Wherever practicable habitable buildings are orientated to avoid Where adjoining substations or major electricity infrastructure,
direct overlooking of major electricity infrastructure or habitable buildings are orientated so that the majority of
substations. outdoor living areas and windows of habitable rooms face away
from the infrastructure.
Earthworks and Drainage
PO21 No acceptable outcome provided
**FINAL DRAFT Post Consultation 2019** Page 6 of 7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.