2019-12-11 SM Agenda - Item 1 - Attachment 4 - Final New Noosa Plan Part 8-9 Schedule Appendix Track Change version

of 195

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (14.9 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
      Veterinary Service
      Amenity
      PO16PO17                                                           AO16AO17.1
      Veterinary clinics and veterinary hospitals are designed and       Animal holding areas are well insulated or buffered from
      operated in a manner which ensures that the visual and             adjacent uses to reduce noise levels.
      acoustic amenity of adjoining sensitive land uses are not
      adversely affected.                                                AO16AO17.2
                                                                         The treatment of animals is undertaken in a fully enclosed
                                                                         building that has sound reduction measures incorporated into
                                                                         the design.



     Table 9.3.7.3 Criteria for assessment (part)
      Performance outcomes                                               Acceptable Outcomes

      Service Station
      Location
      PO17PO18                                                           No acceptable outcome provided
      Service stations are sited in locations that are compatible with
      the existing and proposed character and amenity of the area
      and where it can be supported by the existing road network.
      PO18PO19                                                           AO18AO19
      The site is of a size to accommodate the service station and       The site has:
      associated car parking, access ways and landscaping.               (a)   a minimum area of 1,500m²;
                                                                         (b)   a minimum frontage of 40 metres; and
                                                                         (c)   where a corner site, a minimum frontage of 30 metres to
                                                                               each road frontage.

      Building design and siting
      PO19PO20                                                           AO19AO20
      Service stations are sited and designed to maximise                Publicly accessible parts of the service station, including the
      surveillance from adjacent streets and on­site activities.         point of sale and the entrance to any external toilets, are well lit
                                                                         and clearly visible from areas of activity within the site (such as
                                                                         petrol pumps) as well as from adjacent uses and the street.
      PO20PO21                                                           AO20AO21.1
      Buildings, structures, driveways, tanks and fuel bowsers are       Fuel pumps are a minimum of 8 metres from any frontage.
      sited to:
      (a)   ensure the safe and efficient use of the site;          AO20AO21.2
                                                                    Inlets to bulk fuel storage tanks are located so tankers stand
      (b)   maintain visual amenity and streetscape character;
                                                                    wholly within the site and on level ground while discharging fuel
      (c)   provide adequate separation to adjoining land uses; and into tanks.
      (d)   not cause an environmental nuisance to neighbouring
            properties.

      PO21PO22                                                           AO21AO22.1
      Customer air and water facilities, and any automatic               Customer air and water facilities, and any car washing facilities
      mechanical car washing facilities, are located to ensure that:     are setback a minimum of 5 metres from any residential
      (a)   vehicles using or queuing to use such facilities are         property boundary.
            wholly within the site; and
                                                                     AO21AO22.2
      (b)   an adequate buffer area can be provided to any adjoining
                                                                     Where the buffer area adjoins a residential use the boundary is
            residential use.
                                                                     screened and landscaped to reduce any negative amenity
                                                                     impacts.
      PO22PO23                                                          AO22AO23.1
      The layout and design of the service station ensures that on site Sealed impervious surfaces are provided where potential spills
      operations do not cause any environmental nuisance or harm        of contaminants may occur.
      or result in the release of untreated pollutants.



**FINAL DRAFT ­ Post Consultation 2019**                                                                                                 Page 6 of 9
Log in to download the original file

2019-12-11 SM Agenda - Item 1 - Attachment 4 - Final New Noosa Plan Part 8-9 Schedule Appendix Track Change version(PDF, 14MB).pdf · 14.9 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.