Original source · versioned page text
MCU14/0068 Tewantin & Doonan Locality Code compliance table(attachment 7 of 10)
column 1 column 2 Proposal Complies
Specific Outcomes Probable solutions (if code assessable)
is equivalent to the maximum allowable
population in persons multiplied by
40m2.
O10 For the Neighbourhood Centre The proposal will not be located in the NA
Zone and the Business Centre Zone the Neighbourhood Centre Zone or the Business
maximum plot ratio does not exceed— Centre Zone.
a) 0.8:1 for the first 2,000m2 of site areas;
plus
b) 0.3:1 for the balance of the site areas
in excess of 2,000m2.
Flooding and Drainage
O11 Buildings and other works are S11.1 For new buildings or structures or The proposal will not comprise the provision NA
designed and sited to – additions of more than 50m2 gross floor area to an existing of any new buildings or structures or
a) Provide flood free access to building or structure, floor levels for habitable rooms are— additions of more than 50m2 GFA.
premises and flood free a) for areas where minimum floor levels are available—not
habitable areas; less than the specified level;
b) Allow only minor, short term and b) for areas where flood modelling is available—a minimum
infrequent flooding of non- of 500mm above the modelled flood level; and
habitable areas; c) for areas where flood modelling is not available, a
c) Ensure carparking areas can be minimum of 500mm above the highest known flood level;
adequately drained; AND
d) Ensure drainage does not
adversely impact upon other S11.2 Where Council infrastructure is available— The proposal will utilise existing Council S11.2
premises; and a) any drainage (from buildings and land) flows to that infrastructure, where available. As the
e) Ensure filling or excavation does infrastructure; and proposed development, in terms of
not adversely impact upon b) the infrastructure has the capacity to accept any drainage, will essentially utilise the subject
other premises by— additional loading; site in the same manner as its current form,
i. causing ponding of water on AND no additional loading will occur.
the site or nearby land;
ii. increasing flooding, which S11.3 For Residential Uses— The proposal will not be related to a NA
adversely affects the safety or a) where slab on ground construction is used, filling does not residential use.
use of any land upstream and extend more than 1m beyond the building footprint and
downstream; and access to car parking areas, measured from outer walls of
iii. adversely affecting the flow the building; or
of water in any overland flow b) the design consists of a suspended floor construction;
path. AND
TEWANTIN & DOONAN LOCALITY CODE PAGE 5 OF 9
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.