Original source · versioned page text
Appendix D - Landscaping Plans
Plans and drawings: the text below has words only, no drawings.
Determining the Radius of the TPZ (Tree Protection Zone)
· DBH (Diameter at Breast Height) - nominal trunk diameter at 1.4m above ground level
· TPZ should not be less than 2m nor greater than 15m (except where crown protection is required)
· TPZ = DBH X 12
· TPZ of palms, other monocots, cycads and tree ferns should not be less than 1m
· Variations and encroachments to the TPZ in accordance with A.S. 4970-2009 NOTES:
Ensure crown of rootball level is set higher than adjacent finished ground levels to prevent excessive ponding around rootball.
When footpath is adjacent to street tree install root barrier to footpath side of plant pit as per notes above.
3x Tube Ø
1800
Full and even crown, typical
Tubestock plant as specified
2 - 50mm x 50mm x 2400mm F14 hardwood
centrally pointed non-treated stakes to be
driven vertically into ground outside of the
Fluorescent orange 5.5k.g 50mm wide hessian tree ties rootball and shall have a finished height lower
Form shallow saucer shaped depression
barrier fencing mesh secured wrapped loosely around trunk, than the tree's lower lateral limbs
around plant base
/ tied 100mm below top of star then a figure 8 and secured to
Measurement pickets at 300mm centres stake with galvanised nails or
taken for DBH Form shallow saucer shaped depression
staples. Position tree tie between
Yellow plastic capped around base of plant and keep mulch 50mm
100mm deep organic mulch as specified,
Fencing 1/3 to 1/2 overall height of tree.
star pickets from trunk base
minimum 50mm clear of plant stem
Vegetation to 1200mm painted yellow
1.4m
100mm deep organic mulch as specified.
be protected Ameliorated site topsoil as specified, avoid
Mound mulch at edge of plant pit to collect
Ground line compaction, typical
water to fall down edges of plant pit.
Crown DBH
600mm
TPZ Turf as specified
150mm deep cultivated subgrade, typical
NOTES:
· Protective fencing to be installed around the TPZ to the commencement of any site works
Slow release fertiliser as specified. Use
· Protective fencing identifying the TPZ, to be visibly signed within the development site. Lettering to comply with Tree pit to be excavated to nominal depth of
phosphorus free tablets for Banksia,
A.S.1319. 600mm. Backfill hole with 100% friable
Callistemon and Grevillea species.
Slow release fertilizer
· Fence posts and supports to have a diameter greater than 20mm, located clear of roots ameliorated site topsoil firming progressively.
as specified
· Where tree protection fencing cannot be installed, trunk, branch and ground protection as specified by the project All excavated fill to be removed off site. Scarify
Arborist in accordance with A.S.4970-2009 all sides of plant pit, typical. Subgrade
· Within TPZ, mulch to a depth of 50-100mm only for disturbed land
· Maintenance of TPZ includes regular monitoring of soil moisture levels and weed removal by hand and controlled by 100mm deep uniform gravel layer. Provide
appropriate use of herbicide clean connection to road drainage as advised
· TPZs to be monitored, inspected and certified by the project Arborist on site by civil engineer.
· Removal of tree protection measures at practical completion or as indicated by the project Arborist
1 Tree and Vegetation Protection Detail N.T.S. 3 Tree Planting - in Garden or Turf 1:30 5 Tubestock Planting N.T.S.
LD3 Typical Detail LD3 Typical Section LD3 Typical Section
Plant pit 2x width of respective pot. 2x pot Ø Shrub / groundcover / tufty
Scarify all pit walls and bottom, typ. grass plant species per plan 600mm
Pot Ø typical
Backfill plant pit with specified 100mm deep and settled organic
topsoil, avoid compaction, typ. mulch as specified, keep minimum
50mm from plant stem. Form shallow
dish drain to base of plant, typ. Varies,
Garden topsoil as specified,
avoid compaction, typ. refer
Turf as specified Plans
150mm Topsoil as specified
100mm, typ.
Metal Edging as specified Slow release fertiliser as specified.
2x rootball depth, typ. Use phosphorus free tablets for
Banksia, Callistemon and Grevillea
100mm mulch as specified species.
Tapered Edging Stake as specified
150mm, typ. 150mm deep cultivated
300mm Topsoil as specified subgrade, typ.
150mm cultivated subgrade, typ.
Existing subgrade, typ.
Existing subgrade Road Back of kerb or hardstand Turf Roll, typical
2 Metal Garden Edge N.T.S. 4 Potted Shrub, Groundcover Planting 6 Turfing
LD3 Typical Detail LD3 Typical Section Detail N.T.S. LD3 Typical Plan Detail N.T.S.
NOTES:
This plan is Copyrighted © by Bird Landscape Design (Brian Bird - AILA RLA #1736).
Landscape Operational Works Package Project: BIRD LANDSCAPE DESIGN
Any reproduction or unauthorized use without written consent from Job No: 2340 Proposed Duplex Landscape Architecture, Urban Design, Land Planning
Bird Landscape Design is strictly prohibited. 55 Doonella Street, Tewantin, QLD 3 Vector Place, Little Mountain, QLD 4551 Australia
Do not scale from PDF plans. M: +614 7705 5222
All dimensions in millimetres unless noted otherwise.
LD3 Details E: [email protected]
29.06.23 A For Application BB BB
Sheet Title Sheet 3 of 4 Client: Rowan Anderson W: birdgolfdesign.com
DATE ISSUE DESCRIPTION DRAWN CKD
See the original
The page text is free to read. Viewing or downloading an original file needs an account.