07/1010 - Response to Information Request [As Published] · 132007.1010
Councifs Reference: 2007/1010 Our Reference: 00706 LO8 NG Our Project Planner. Nadine Gorton | Y ) a rtoo consultinga 17" September 2007 town planners + urban designers Chief Executive Officer Noosa Shire Council PO Box 141 TEWANTIN Q@ 4565 Attention: Denis Wallace — Land Use Section Dear Denis, RE: Application for Development Permit for Material Change of Use of Premises for Multiple Housing — Type 2, Duplex at 18 Kingfisher Drive, Peregian Beach described as Lot 122 on RP9311: Welliclose Pastoral | refer to the above development application and in particular to the request for additional information issued by Noosa Council and dated 10" July 2007. This request listed three (3) items that Council considers it requires in order to complete its assessment of the above application. The applicant has decided to respond to three (3) of these items as detailed below: Land Use item 1. Comment: item 2: Comment: Amended plans indicating: 1.1. A minimum side boundary setback of 1.5m to the aluminium portal blades above the basement entrance to allow for the establishment of screening vegetation between the building and the boundary in accordance with Specific Outcome 05 of the Eastem Beaches Locality Code. 1.2. Garden beds with a minimum width of 0.5m along side boundary fences in accordance with Specific Outcome 01 of the Landscaping Code. An amended site plan numbered WD.202 P6 is attached. This plans details a 0.5 metre setback for the portal blades and 1.5 metre landscaped setback along the side boundaries. Please indicate the species types for the existing vegetation indicated on the plan of survey (Kimmorley & Assoc. Dwg. 01250-01). A Site Survey Plan prepared by Kimmorley & Associates is included as Attachment 2. This plan details the location of all mature vegetation located on site. Land Development item 3: SUNSHINE COAST OFFICE As a condition of approval all site stormwater drainage shall be by means of a gravity system. Additionally the maximum discharge of storm water drainage allowable to Council's kerb & channel street drainage system at any one location is 25 litres/second. It is noted that the proposed driveway drains toward the car parking which is below the level of the road kerb in Kingfisher Street. It is also noted that drainage to Kingfisher Street will be difficult along the northem side of the site given the location and level of the proposed driveway. Please provide a preliminary drainage plan for the site. GYMPIE OFFICE 1/199 GYMPIE TERRACE NOOSAVILLE - PO BOX 1684 NOOSA HEADS Q 4567 1/28 REEF STREET GYMPIE - PO BOX 391 GYMPIE Q 4570 TELEPHONE 07 54555425 - FACSIMILE 07 54655725 TELEPHONE 07 54827440 - FACSIMILE 07 54824952 [email protected] [email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 3 pages
Page 2
Comment: A drainage plan prepared by SCG Consulting Engineers numbered 1782 -SW1 is attached. The supply of this additional information completes the applicant's response to Council's request for additional information in relation to this development application. It is requested that Noosa Council completes its assessment of the above application as soon as possible now that the decision making period has commenced under the Integrated Planning Act 1997. Yours sincerely NE ator Nadine Gorton Senior Planner Martoo Consulting Pty. Ltd. Ce. Kidd & Co
Page 3
/ 1 \LOWER FLOOR
\wo202 / SCALE 1:100 @A3
SOFTSCAPING
SOFTSCAPING
enw >}
2 STOREY
BUILDING PAVKION
kidd
+CO
designers
39.811m
Te
92°13'20"
20 Duke Sbest
‘Sunshine Beach QLD 4557
=| = SS SS SS — — — — PO Bax 262
39,811m
Noosa Heads OLD 4567
Telephone 07 5447 5633
Facsimile 07 5447 5833
[email protected]
ww Kiddoo.com. au
Thescranrg bobo
readincongncton ah
intemal ouvras .
i 1 |
Fen ee nents LIVING ......... ae
ROOM y
21520"
cS
KITCHEN
‘timber
Project
PROPOSED DUPLEX
Locaon
18 KINGFISHER DRIVE
PEREGIAN
272" feature wall
Chont
WELLCLOSE
PASTORAL CO.
Drawing Tee
LOWER FLOOR PLAN
‘Scale Cae
as shown DEC 06
Cram By ob Ne
SF 0638
Drawing No. Issue Na,
WD.202 (Ps)
Page 4
DRAWING SIZE - A2,
aaa
GARAGE
&
oo
A
OT FENCED
39.814m —_92°73°20"
x
6.200 ORE
o
%
WATER TANK OVERFLOW
CONC DRIVEWAY
ae AWNING —_
SHE PLAN
MANAGEMENT PLAN
(Scale 1:100)
~ Ensure the inflow into the pit is protected with
on gpproved leaf and silt quord.
- The pit MUST be wrapped in geofabric cloth as
specified.
- The pit should be backflushed on a requiar basis
{3 months) to remove ony silts or similiar
STORMWATER SOAKER PIT DETAIL
materials. :
Surtace - The pit should only be used for the disposal of
0 Bund stormwoter.
<a Capped C t id
7 pped Concrete encase
| _BACKFILY ~ 909 backtlush point
c ot 3
Flow , . -
a
Slotted Agg pipe ° bos S ea al =
150 min clearance
_to base. As per plan 20mm clean aggregate
* fully encased in
geofabric.
Pipe Grid at Base
NOT FENCED
»
sacl
TER SOAKAGE PIT
N
o>
TO
eM
ee
46
DRIVEWAY
&
1,542.5x1.0m(0)
‘STORMWATER SOAKAGE FIT
TO DETAIL.
af
garden wall
top of roof
TRI 16.75
LEGEND
7 INDICATES EXISTING SURFACE
38.00 CONTOUR AND LEVEL TO AHD.
(Gq) ~—s INDICATES PROPOSED FINISHED SPOT
SURFACE LEVELS TO AHD.
“
- EXISTING SURFACE SPOT LEVELS.
rau, INDICATES DIRECTION OF FALL
TO FINISHED SPOON DRAINS.
conc footpath
NN
Revision | Description - Dae
Co
‘By
DRIVEWAY
/ CROSSOVER
®
“:
VE
SIGN
R
KINGFISHER D
BD
TBM SCREW
| -, AHD RL 7.33
*s
a;
FIRE
HYDRANT
TELSTRA
PIT
POWER
pair
Issue:
CONSTRUCTION
CONSULTING ENGINEERS
SCG structural - hil + geotechnical ©
ABN 40.098 481 899
18 DUKE STREET SUNSHINE BEACH QLD.4567
Ph (07) 5447 5544 Fax (07) 5447 2634
Ti DRAINAGE PLAN.
Project Lot 122 Kingfisher Drive
Peregian Beach OLD
ket 3361.05
¥
Date: August 2007 | Drg No. 17282-Sw1]"