Council archive · source document
SCG 26281_OW1 to SW1_Issue 2 · MCU17/0004
Attached to the e-mail MCU17/0004 - Response to Information Request - 46-48 Elizabeth Street, Noosaville.
ELIZABETH STREET
BM: NAIL IN KERB
RL: 1.600
43
1. 47
57
1. .40
1. .35
57
5
58 4
61
1.
51 1.5
1. 1.4
48
54
1.
1.
1.
PP
1
1
PP
59
1. .55
1.
54
56
50
54
1
1.
1.
1.
1.
40
55
WM
1.
1.
WM
66
54
1.
03
1.
58
20.92 20.92
58
2.
1.
59
4
1.
6
1.
1.
COMMON PROPERTY
94
1.
66
1.
RP78252 17.10
2
74
2 STOREY
1.
BRICK UNITS
35.46
GTP395
3
9
67
5
1.
1.
6.09 7 2
66
1.
77
742m²
1.
1.
SHED
2
35.46
630m²
SINGLE STOREY GTP156216
68
5
1.73
1. 1.
TIMBER & FIBRO
18.36
DECK
IO
MH
LL: 1.53 CP
49
1.
5
50
47
IL: 0.52 1.
6
1.
1.
14.83 20.92
60
1.
SINGLE STOREY4 RP72986
DECK 2 STOREY
BLOCK & H'PLANK
6 GTP671
BLOCK UNITS
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — Al
LOTS 2 & 3 ON RP 78252
Level Datum AHD
N Level Origin PM 56277, RL 1.635m
&
THIS FOOTING IS FOUNDED Xa | |
BELOW CRITICAL DEPTH
UNE AND IS STABLE.
PIERS OR UNDERPINNING FOUNDED
BELOW THE CRITICAL DEPTH LINE
WOULD BE NEEDED 10 SUPPORT
ANY FOOTING THAT IS FOUNDED
ABOVE THE CRITICAL DEPTH LINE.
CRITICAL DEPTH LINE
www.dialbeforeyoudig.com.au
SAY DIAL 1100
"Wy BEFORE YOU DIG
REFER DRG OW4 FOR
SEWER PROTECTION
DETAILS
EXISTING STRUCTURE /DWELLING
INCLUDING NEIGHBOURING
ALLOTMENTS
THE BUILDER/CONTRACTOR
SHALL CONFIRM ALL
RELEVANT LEVELS PRIOR 10
COMMENCING WORKS.
Ups UNSTABLE O ae THIS FOOTING WITHOUT
PIERS IS FOUNDED
ABOVE CRITICAL DEPTH
LINE AND IS UNSTABLE.
LINE OF PROPOSED TRENCH
~~ EXCAVATION. OR EXISTING
SERVICES TRENCH
\Y
. fers
Horizontal 30_Degtees\\
NOTE:
THIS DETAIL ALSO APPLIES TO EXISTING FOUNDATIONS
ON NEIGHBOURING PROPERTIES. SHEET PILING MUST
BE INSTALLED WHERE EXISTING FOOTINGS WILL BE
FOUNDED ABOVE ANY EXCAVATION CRITICAL DEPTH
LINE
REFER DRG OW4 FOR
SEWER PROTECTION
DETAILS
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
TO BE PROTECTED IN ACCORDANCE WITH THE
AUTHORITY RESPONSIBLE FOR THE SERVICE
BM: NAIL IN KERB
g 9 6 Ao 4 . RL: 1.600 A
rey YZ ~ a 5 E
E rr E Se SE RE ee PR E x85 at
S nN Ne nS © No Ne
w iw W w w w—44i4—_w x? w Wit w w
lg RP. BGINDARY eo
a 7 SP ¥ = C
NO FLL Croan RW NPE 2 ! \ RNP Sa, Cy”
| ma - COMM
| \ = PROPOSED TIMBER
LANDSCAPING WALLS ofl
= | \ ADJACENT PROPOSED lS
: Ss DRIVEWAY IF REQUIRED. “
8252 2
eo @
= | FLL.1m APPROX. FILL! VOLUME. 1495m° 2
| ig @ 4 2s
/ 2 FILL-1.0m BR
Ino FILL FILL-1.0m 2g _
12 : 2G 3 =| GTP39
ee - nf oe >= tp -$ —_ -
6.09 « & 7 =|
e 4 742m? |
SHED 2 3) | i
° 1 | NX.
630m? z) 6 B
FILL=1.0m > &
REY - s | ° 2G TP156.
RO ] oe ~ FILL-0.1.2m &
Rey) Ig a
ae ES “
< Pa ©
O |
— MW EX. SMH lO
"8 2 | FILL-0.9 C P
: 1 -0.9m
Te 05 le tem ead RW TPE | 2
x 14.83 — _2R)P2 BOUNDARY
EX. SCP L
A | D STOREY GTE
SINGLE STORE RP72986 ' BLOCK & H'PLANK
SITE PLAN — EARTHWORKS & RW SETOUT
Scale 1: 200
ALL LINE MARKING TO BE IN ACCORDANCE
WITH THE QUEENSLAND MANUAL OF UNIFORM
TRAFFIC CONTROL DEVICES & A.S 2890.1
PARKING FACILITIES PART 1: OFF-STREET CAR
PARKING
1/N12 TOP ——__| —
190 BLOCK — CORE
FILLED N12-400 V & H—*}:} -P
— LAP BARS 500MM.
ALL CORES CLEARED
LEGEND
Ng EXISTING SURFACE SPOT LEVELS.
SW/EX
Fill-1.8m
R.P. BOUNDARY
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM
EXACT LOCATION PRIOR TO WORKS
INDICATES EXISTING STORMWATER
DRAIN
INDICATES DEPTH OF CUT OR FILL
AS NOTED
! FILLED LOT
GROUND LEVEL
| °
PROVIDE FULL HT.
MOVEMENT JOINTS AT
8.0M CTRS.
(| ~+———— 200MM FREE DRAINING
BACKFILL WITH AGI PIPE
TO OUTLET.
150 THK HEEL SL82
MESH TOP 40 COVER.
SLI1TM TOP & BOTTOM
R6 LIGS AT 900 CTRS
SPOON DRAIN OR SIMILIAR
TO RE-DIVERT STORMWATER.
GEOFABRIC OR SIMILIAR FOR
SILT/FINES RETAENSION.
200X400MM FREE DRAINING
BACKFILL IN GEOFABRIC
BEFORE POUR VIA
CLEAN-OUT BLOCKS. NN P
GROUND LEVEL
— IRN”~«*d —
= Sa -
= _|
o a
Oo
+) 2 \
H_ | B S
1500 | 1000 ——
1200 | 800
800 | 500
500 | 300
300 B4.000
(—_\BLOCK RETAINING WALL — TYPE 1
\. _/ TYPICAL SECTION
1.
‘|
VERTICAL MEMBERS AS PER
TABLE, 1200 CTRS. RAKE
BACK AT ANGLE SHOWN.
a
=z
“| 200X50 HORIZONTALS
S FOR DEPTHS UP TO 1600
es BEYOND USE 200X75.
=x
GROUND LEVEL
SS
DBPRAHASSSBEETIRIDD.
4009
WRAPPING WITH AGI PIPE TO
OUTLET.
GRADE CONCRETE AWAY
FROM POSTS.
20MPA COMPACTED
CONCRETE.
ALL MEMBERS 10
BE H4 TREATED
HDWD
SLEEPER RETAINING WALL ALTERNATIVE DETAIL.
'H RETAINED | VERTICAL MEMBER | FOOTING DEPTH
(D X B)
600 200 x 75 400
900 200 x 75 900
1200 200 x 100 1200
1600 100 x 200 1500
2000 2/125 x 200 1800
-
VERTICAL |
MEMBER Ol
fann—1__?——)_'m1:100 © Al
1:200 @ A3
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL
DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL
DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW
WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE
DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY 10 BE 125mm THK. EXCLUDING ANY FINISHED
TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WTH EVERY 2ND MESH
WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR TO
WORK COMMENCING
FILLING NOTES:
—THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND
DEBRIS.
— THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL DRUM
ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%. THE
COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7
BLOWS PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER
FOR A DEPTH OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF
COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
— THE FILL MATERIAL CLEAN GRANULAR MATERIAL (I.E. SAND TO A
CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY
ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF LESS THAN 12%
(PLASTICITY INDEX LESS THAN 25%, LINEAR SHRINKAGE OF 15%). THE
PROPOSED MATERIAL IS TO BE INSPECTED BY SCG CONSULTING
ENGINEERS PRIOR TO ITS REMOVAL TO ENSURE ITS COMPATABILITY.
— THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH
AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A LEVEL 1
CERTIFICATION WITH A MINIMUM RELATIVE FIELD DENSITY OF 95%.
COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG
CONSULTING ENGINEERS FOR APPROVAL.
— FILLING AND COMPACTING ADJACENT EXISITING STRUCTURES IS TO BE
IN STRICT ACCORDANCE WITH THE ASSOCIATED DETAILS AND
SPECIFCATIONS.
— AREAS WHERE EXISTING STRUCTURES OR TREES ARE REMOVED SHALL
BE BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN
ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE
FIELD DENSITY OF 95%.
— ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
PREPARATION SHALL BE REMOVED AND REPLACED WITH THE APPROVED
FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO
ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%.
— SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED
PRIOR TO CONSTRUCTION COMMENCING.
KEY
EX. SWPT EXISTING STORMWATER MANHOLE /PIT
EX. SCP EXISTING SEWER CONNECTION POINT
RC. HW. — REINFORCED CONCRETE HEADWALL
EX. SMH — EXISTING SEWER MANHOLE
EX. SWMH EXISTING STORMWATER MANHOLE
SWMH NEW 1050 STORMWATER MANHOLE
E.0.B. EXISTING EDGE OF BITUMEN
K&Cc EXISTING KERB & CHANNEL
NS.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL POWER POLE
KERB EXISTING KERBING
Revision Description Date
Issue:
FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
‘ABN 40 098 484 699,
C) St
DEBUILD TA
Title:
OPERATIONAL WORKS:
EARTHWORKS & RW DETAILS
Project
Lots 2 & 3 RP/8252
Elizabeth St, NOOSAVILLE
Date: Drawn
Nov 16 CSK
Drg No. Rev
| Fass, d 26281-OW3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SCG 26281_OW1 to SW1_Issue 2.pdfRelated documentApplication case desk ↗
SCG 26281_OW1 to SW1_Issue 2.pdfRelated documentApplication case desk ↗
SCG 26281_OW1 to SW1_Issue 2.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.