Council archive · source document
SCG 26281_OW1 to SW1_Issue 2 · MCU17/0004
Attached to the e-mail MCU17/0004 - Response to Information Request - 46-48 Elizabeth Street, Noosaville.
ELIZABETH STREET
BM: NAIL IN KERB
RL: 1.600
43
1. 47
57
1. .40
1. .35
57
5
58 4
61
1.
51 1.5
1. 1.4
48
54
1.
1.
1.
PP
1
1
PP 9
5
1.
1.
55
54
56
50
54
1.
1.
1.
1.
1.
40
55
WM
1.
1.
WM
66
54
1.
03
1.
58
20.92 20.92
58
2.
1.
59
64
1.
1.
1.
COMMON PROPERTY
94
1.
66
1.
RP78252
17.10
2
7 4 2 STOREY
1.
BRICK UNITS
35.46
GTP395
3
59
67
1.
1.
6.09 72
66
1.
77
742m²
1.
1.
SHED
2
35.46
630m²
SINGLE STOREY GTP156216
5
68
1.
TIMBER & FIBRO
18.36
DECK
IO
MH
LL: 1.53 CP
49
1.
50
47
IL: 0.52
65
1.
1.
1.
14.83 20.92
60
1.
SINGLE STOREY4 RP72986
2 STOREY
BLOCK & H'PLANK
6 GTP671
DECK
BLOCK UNITS
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — Al
|
NN
LOTS 2 & 3 ON RP 78252
Level Datum AHD
Level Origin PM 56277, RL 1.635m
BOUNDARY
BLOCK BOUNDARY
WALL AS SPECIFIED.
FILLED ALLOTMENT
. WALL.
FILLED ALLOTMENT
1506 ADJOINING DRAIN FROM
GRATE CONNECT TO 150¢ UPVC
OX hr
1500 PIPE WITH
RECTANGULAR GRATE OVER,
PLACE AT LOW POINTS
ALONG NEIGHBOURING BLOCK
7~— EXIST
GL
7K
NEIGHBOURING ALLOTMENT
SWP1_~ TYPICAL DETAIL >
BOTTOM LAYER TO HAVE
1500 uPVC PIPE WITH
TRENCH GRATE INSTALLED
IN RETAINING WALL.
ENSURE INLET IS 20mm
ABOVE ADJACENT GROUND
LEVEL.
1509 uPVC 1 in 100 GRADE TO STORM WATER
PIT ON STREET. IL TO MATCH EXISTING G.L IN
NEIGHBOURING PROPERTY.
SECTION X-X
| RAINFALL
ROOF RUNOFF
V
FILTRATION
DRIVEWAY
y
§
COUNCIL STORMWATER
SYSTEM
WATER CYCLE DIAGRAMATIC
INFILTRATION PITS
TREAT FIRST FLUSH RUNOFF FROM ROOF'S
—STORAGE AND ONGOING INFILTRATION
REDUCES DEVELOPED SITE RUNOFF
Zz
PITS
www.dialbeforeyoudig.com.au
DIAL1100
BEFORE YOU DIG
BLOCK RETAINING
EXISTING GROUND LEVEL IN
! NEIGHBOURING PROPERTY.
CREATE FALL TOWARD
ROAD RESERVE IN FINISHED
GROUND PROFILE.
THIS SWP PROVIDED AS
DISCHARGE POINT FOR
NEIGHBOURING ALOTMENT
DRAINAGE.
EXISTING HCB’s & NEW SW DRAINAGE
LINE TO BE PROTECTED AS PER
SEWER/STORMWATER PROTECTION
DETAILS ON DRG 26281—OW1.
AUSDRAIN ENVIROMODULE 2
INFILTRATION CELLS. REFER
DETAIL ON THIS SHEET.
2/125x75x4.0 RHS (GALV.)
LAID AT 1 in 100 MIN.
INSTALL TO NEW KERB
ADAPTORS AND MAKE
FOOTPATH GOOD.
ELIZABETH STREET
2/125x75x4.0 RHS (GALV.)
LAID AT 1 in 100 MIN.
INSTALL TO NEW KERB
ADAPTORS AND MAKE
FOOTPATH GOOD.
FALL LANDSCAPED AREAS TO
FORMED FLOW PATHS TO DIVERT
r— RUNOFF TO GRATED DRAINS AND
SW PITS. 1 in 100 MIN FALL.
TYPICAL.
BM: NAIL IN KERB
a A KERB ® RL: 1.600 x
-——" 10] 7" PR? - e We
© a(t eo
we ll & ” w il °
Ww vf. Ww Ww Wik TI Ww
- po UE 2) rt te
No x q sw V3E
FALL
x [210]x ys
4
2
===-4" 1000 upvc © 1-100 _)
IDP.
1:100 *)
ALL PIPES 10 BE LAID AT 1 IN 100 MIN.
UNLESS NOTED
CELLS
AUSDRAIN INFILTRATION SOAKER PIT DETAIL
UNIT 1 OLa-- ! WP!
| FFL 2.70 NE] FAL 0 2
b UNIT 2 &
x --- > +
235 a 2.68 FFL 2.70 Ns
Zs| 2FALL Gl ir —
FALL. Sun I SL 2.4.
| 4p <s p OP eta TP39
B69 atl Ce we NP
: z A 7 |
e tH \ dein? | Wie
SHEDe | ds
S PE — BS
eG WY SS DP 2 1.0m
3s ys /
B I / /
xEY HE ! UNIT 3
sRO | SF io | ¢ Gal FFL 2.70 nh
x q P|
OQ i | 7x7 Vv sw——__—] |
| 2 2
—J WwW EX. SMH We) eel 268 =| |
a lex. Sop
MH is CP3 xe POOL
—— EL: 1.53 Mae OO Ne a
__ IL: 0.52_ sw Sw. Le Lit é
HATCHING INDICATES PROPOSED & 14.83 P. BOUNDARY, ( 20.92 _S
1.0m WIDE EASEMENT FOR EX. SOP §
INTER-ALOTMENT DRAINAGE. >
D STOREY
SINGLE STORE RP72986 ! VBLOCK & H'PLANK
SITE PLAN — STORMWATER MANAGEMENT
Scale 1: 200
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
TO BE PROTECTED IN ACCORDANCE WITH THE
AUTHORITY RESPONSIBLE FOR THE SERVICE
AUSDRAIN ENVIROMODULE 2
INFILTRATION CELLS 10 IN LINE,
THIS DRAWING IS TO BE READ IN CONJUNCTION WRAPPED IN GEOFABRIC
WITH THE STORMWATER MANAGEMENT REPORT BY
SCG CONSULTING ENGINEERS (No. 25231(SWM) STORMWATER 1.0.S
INFLOW
PROVIDE SLOTTED PIPE
THROUGH BOTTOM OF
—°P5 —300Sq FIELD INLET, PRE-CAST
= CONCRETE WITH RAISED GRATE FOR
LANDSCAPED AREA DRAINAGE,
2/125x75x4,0 RHS (GALV.) SS ctonmwaTeR VERT. INLETS 70
LAID AT 1 in 100 MIN. [0 COLLECT -PONDING FROM
INSTALL TO NEW KERB NEIGHBORING PROPERTY.
ADAPTORS AND MAKE REFER DETAIL.
FOOTPATH GOOD.
INDICATES PROPOSED STORMWATER
SW DRAIN EXISTING MIN 1 in 100
GRADE U.N.O.
DP DENOTES APPROXIMATE DOWNPIPE
FREON Ee
DETAIL ON THIS SHEET.
it~
2
LEGEND
INDICATES EXISTING SURFACE
4g.00 CONTOUR AND LEVEL TO AHD.
a
Ne EXISTING SURFACE SPOT LEVELS.
INDICATES DIRECTION OF FALL
FALL.
“TQ FINISHED SPOON DRAINS.
x INDICATES PROPOSED FINISHED
SURFACE LEVELS
GD-150 150(W) GRATED DRAIN WITH
(LOT) HEAVY DUTY GRATE.
DEPTH.
GPS 450Sq PIPE JUNCTION BOX WITH
BOLTED LID, PRE-CAST
CONCRETE.
GP2
450Sq FIELD INLET, PRE-CAST
CONCRETE WITH RAISED GRATE FOR
LANDSCAPED AREA DRAINAGE.
LOCATIONS TO BE CONFIRMED BY
ARCHITECT AND HYDRAULIC
DESIGNER.
OMODULE 2
LLS. REFER
HATCHING INDICATES PROPOSED
1.0m WIDE EASEMENT FOR
INTER-ALOTMENT DRAINAGE.
LOCATE STORMWATER PITS
AT LOW POINT ON
NEIGHBOURING PROPERTY
REFER TYPICAL DETAIL.
FALL LANDSCAPED AREAS TO
FORMED FLOW PATHS TO DIVERT
RUNOFF TO SW PITS. 1 in 100
MIN FALL. TYPICAL.
PROVIDE INSPECTION OPENINGS
(.0.S) FROM SLOTTED PIPE IN
BASE FOR FLUSH OUT or
OVERFLOW GRATE WHERE NO
STORMWATER OUTLET
-
1.0.S
STORMWATER
OUTFLOW
PROVIDE DROPS AT EACH END
OF THE PIT FROM THE MAIN
THROUGH DRAIN TO THE
SLOTTED PIPE IN THE BASE
ALL PIPE PENETRATIONS THROUGH THE GEOFABRIC TO
BE FITTED WITH STAINLESS STEEL PIPE CLAMPS,
GEOFABRIC TO BE LAPPED AT JOINS WITH A ROOT
INHIBITOR PROVIDED ALONG THE JOIN LINES
fann—1__?——)_'m1:100 © Al
1:200 @ A3
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED 10 THE ENGINEER
IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE
THAT ALL NEW WORKS ARE IN ACCORDANCE WITH THE ATTACHED
CRITICAL DEPTH LINE DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY TO BE 125mm THK. EXCLUDING ANY
FINISHED TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY
2ND MESH WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE
EDGE OF CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED
PRIOR TO WORK COMMENCING
HYDRAULICS
1. HYDRAULIC SERVICES SHOWN ARE DIAGRAMATIC ONLY. REFER TO
ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIXTURES.
2. ALL SANITARY HYDRAULICS AND WATER RETICULATION WITHIN: THE
ALLOTMENT BOUNDARY TO BE IN ACCORDANCE WITH AS3500.
3. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF AUTHORITIES
HAVING JURISDICTION, AFTER OBTAINING ALL NECESSARY PERMITS AND
APPROVALS.
4. THE CONTRACTOR IS TO CONFIRM THE POSITION OF ALL EXISTING
SERVICES AS INDICATED ON THESE AND ASSOCIATED PLANS PRIOR 10
THE COMMENCING OF WORK.
5. STORMWATER DRAINAGE PIPES SHALL BE CLASS SH UPVC OR CLASS
2 R.C.P RUBBER RING JOINTED PIPE AS NOTED LAID AT A MINIMUM
GRADE OF 1 IN 100 U.N.O. JOINS ARE TO BE CONSTRUCTED IN
ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTS.
6. SEWERS 100MM DIAM. UPVC U.N.O. AND LAID AT A MINIMUM GRADE
OF 1 IN 60.
7. WATER SUPPLY PIPEWORK BELOW GROUND |S 10 BE ;
63MM DIAM. OR LESS - HIGH DENSITY TYPE 50
CLASS 12 POLYETHYLENE
8. ALL ABOVE GROUND AND INTERNAL WATER SUPPLY PIPEWORK TO BE
TYPE B COPPER.
9. WATER SERVICES ARE NOT PERMITTED IN GROUND SLABS AND ALL
JOINS AND CONNECTIONS SHALL BE MADE ABOVE THE SLAB.
10. FIRE HYDRANTS ARE TO BE INSTALLED ARE TO BE INSTALLED IN
ACCORDANCE WITH AS2419.1. HOSE REELS ARE 70 BE INSTALLED IN
ACCORDANCE WITH AS2441.
11, CLEAN—OUTS, INSPECTION OPENINGS AND CLOSING CAPS SITUATED IN
VEHICULAR OR PEDESTRIAN PAVEMENTS ARE TO BE FITTED WITH EITHER
BRASS OR CAST-IRON COVERS.
12. ALL IN-GROUND VALVES SHALL BE IN ACCORDANCE IN APPROVED
CONCRETE PATH BOXES.
13. ALL WASTE PIPES AND WATER SERVICES PENETRATING SLABS TO BE
WRAPPED IN AN APPROVED FLEXIBLE JOINT JOINT WRAPPING.
14. THE TERM ’SERVICE’ REFERS TO THE MINIMUM INTERNAL PIPE
DIAMETER UNLESS NOTED OTHERWISE.
KEY
EX. SWPT EXISTING STORMWATER MANHOLE /PIT
EX. SCP EXISTING SEWER CONNECTION POINT
RC. HW. = REINFORCED CONCRETE HEADWALL
EX. SMH — EXISTING SEWER MANHOLE
EX. SWMH EXISTING STORMWATER MANHOLE
SWMH NEW 1050 STORMWATER MANHOLE
E.0.B. EXISTING EDGE OF BITUMEN
K&C EXISTING KERB & CHANNEL
NS.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL POWER POLE
KERB EXISTING KERBING
A _|iNFo REQUEST Hew 1. (wCUT7/0004) [07/02/17
Revision Description Date
Issue:
FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
C) St
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
‘ABN 40 098 484 699,
DEBUILD TA
Title:
OPERATIONAL WORKS:
STORMWATER MANAGEMENT
Project
Lots 2 & 3 RP/8252
Elizabeth St, NOOSAVILLE
Date: Nov 16 Drawn CSK
Checked: Drg No. Rev
Ffarorsn NV |26281-SW1 | A.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SCG 26281_OW1 to SW1_Issue 2.pdfRelated documentApplication case desk ↗
SCG 26281_OW1 to SW1_Issue 2.pdfRelated documentApplication case desk ↗
SCG 26281_OW1 to SW1_Issue 2.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file