Council archive · source document
Delegated Report - Code - Planning MCU22 0052 [As Published] · MCU22/0052
eastern and western side verges. All vegetation along the road frontage is clear of the
formation and does not appear to pose a risk for vehicle sight stopping distance.
The road is considered to be constructed to an adequate standard for 3 cabins, therefore the
development complies with the Performance outcome.
Flood Hazard
A portion of the site is identified as being susceptible to flooding along the creek and in the lower
lying portion of the lot in the northeastern corner of the site. The 3 cabins, associated structures
and car parking area are all located clear of the flood hazard. In addition, the applicant provided
a Hydraulic Assessment in the Information Request response, with the applicant stating:
The following conclusions have been made:
• based on the proposed locations of the cabins, the areas proposed appear to be free
of flood during the modelled storm events.
• Access to the cabins would be restricted during the design storm events modelled.
Nonetheless so would access to the property based on the unpassable creek
crossings on Eastern Branch Road. Therefore, access from the cabins to a point of
refuge has been considered and can be achieved. This point of refuge would be the
existing dwelling/managers residence at a higher elevation.
• Stormwater quality treatment can be achieved through rainwater harvesting tanks and
buffer areas.
• The environmental footprint for the cabins would be minimal based on the areas
already cleared and the tracks and culverts already in place.
In summary, the proposed cabin locations on the subject site will result in non-actionable
nuisance of stormwater runoff, be free of flooding and have safe refuge opportunities should
it be faced with unpredicted intermittent weather.
Biodiversity, Waterways and Wetlands
Acceptable outcome AO6.1 of the Biodiversity, Waterways and Wetlands seeks - Development
and clearing of vegetation does not occur within:
a) a riparian buffer area;
b) a wetland area; or
c) 10 metres either side of the centre line of other waterways identified on
a Biodiversity, Waterways and Wetlands Overlay Map.
The applicant seeks to construct 3 Short term accommodation cabins, 1 of the cabins is
proposed to be partially located in the riparian buffer. The proposed access and Cabin 3 are
located in the riparian buffer, and therefore is to be assessed against the corresponding
Performance outcome.
PO6 The biodiversity and ecosystem values of waterways, wetlands and adjacent riparian zones
are protected by:
a) avoiding any new development in a riparian buffer area and wetland area;
b) retaining aquatic and terrestrial habitat in riparian zones;
c) maintaining and enhancing wildlife corridors and connectivity along watercourses
and drainage lines for native fauna movement;
d) avoiding edge effects and damage from adjacent land uses;
e) maintaining stream integrity and bank stability by minimising bank erosion and
slumping;
f) maintaining water quality through filtering sediments, nutrients and other pollutants;
and
g) removing pest species and replacing them with local native species.
Council’s Senior Environment Officer has provided the following comments regarding the
proposed development within the mapped Biodiversity, Waterways and Wetlands Overlay:
Page 7 of 18
Document Set ID: 22700275
Version: 4, Version Date: 14/12/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Delegated Report - Code - Planning MCU22 0052 [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.