NOOSA COUNCIL
APPROVED PLAN
MCU21/0027 & OPW21/0047
10 JUN 2021
Timber framed trussed roofs to be in accordance with
engineers design and detail. Provide 0.42mm
COLORBOND® steel BlueScope LYSAGHT
CUSTOM ORB® roof sheeting to be fixed in Formed concrete awning to be in accordance with structural
accordance with manufacturers specifications. A B C D engineers design and detail. Provide Rockcote acrylic render
Formed concrete awning to be in accordance with system with sponge finish and painted with selected colour in
structural engineers design and detail. Provide 7 800 3 090 4 200 accordance with final colour selections to exposed surfaces.
Rockcote acrylic render system with sponge finish and Refer to Rockcote for full coating system details. Provide Emer-
painted with selected colour in accordance with final clad waterproofing membrane and drip groove to u.s of soffit.
8 801
colour selections to exposed surfaces. Refer to
Rockcote for full coating system details. Provide Powder coated aluminium dowel balustrade to planter/terrace.
Emer-clad waterproofing membrane and drip groove 2 552 Balustrade in accordance with NCC D2.16. Balustrade to be a
to u.s of soffit. min. 1000mm high above finished floor level. Refer to detail for
8 300 finishes.
Ceiling
Powder coated aluminium privacy screens. Formed concrete roof to be in accordance with structural
engineers design and detail. Provide Rockcote acrylic render
system with sponge finish and painted with selected colour in
accordance with final colour selections to exposed wall
5 560 surfaces. Refer to Rockcote for full coating system details.
5 600 top of awning
First floor
6 400
Knotwood 50 x 50mm powder coated aluminium battens (50mm
spaces) to form automatic sliding gate. Knotwood Silver Wattle.
3 450 3 450
3 300 top of wall top of wall
top of wall
2 500
Ground floor
Concrete driveway and parking to be in accordance structural
engineers design and detail. Driveway to comply with
AS2890.1. Provide new crossover in accordance with local
Concrete block wall to be in accordance with authority regulations. Driveway grades to be in accordance with
structural engineers design and detail. Provide AS2890.1. Driveway to in selected exposed agg. concrete
Rockcote acrylic render system with sponge finish and blend with tool joints as detailed, provide slip resistant clear
painted with selected colour in accordance with final sealer coat to entire driveway, applied in accordance with
colour selections. Refer to Rockcote for full coating manufacturers specifications.
system details.
Knotwood 100 x 50mm powder coated aluminium
A B C D
battens (50mm spaces) to form screen/fence. Concrete block wall to be in accordance with structural
Knotwood Silver Wattle. engineers design and detail. Provide Crackenback stone facing
by Eco outdoor.
Knotwood 50 x 50mm powder coated aluminium battens (50mm
spaces) to form entry gate. Knotwood Silver Wattle.
Western Elevation
W 1:100
Frameless glass pool fence to be in accordance with NCC
3.9.3, the Building Act 1993, Building Regulation 2006, AS
1926 . Pool fence to be min. 1200mm high above adjoining
finished surface level and have 900mm non climbing zone
as specified in pool legislation.
Frameless glass balustrade to be in accordance with NCC
D2.16. Balustrade to be a min. 1000mm high above
finished floor level. Refer to detail for finishes.
Timber framed trussed roofs to be in accordance with engineers
design and detail. Provide 0.42mm COLORBOND® steel
150 x 40mm folded COLORBOND® ULTRA steel BlueScope BlueScope LYSAGHT CUSTOM ORB® roof sheeting to be
Suspended concrete swimming pool to be in accordance with engineers
Lysaght barge flashing to detail with 180 x 25mm h3 treated fixed in accordance with manufacturers specifications.
design and detail. All pool construction to be in accordance with
primed timber fascia. manufacturers/installers specifications. Pool to have suitable pumps located
in service court in accordance with manufacturers/installers specifications. Powder coated aluminium dowel balustrade to planter/terrace.
Formed concrete awning to be in accordance with structural Provide pool fence to be in accordance with NCC 3.9.3, the Building Act Balustrade in accordance with NCC D2.16. Balustrade to be a
engineers design and detail. Provide Rockcote acrylic render 1993, Building Regulation 2006, AS 1926 & QDC 3.4 . Pool fence to be min. min. 1000mm high above finished floor level. Refer to detail for
system with sponge finish and painted with selected colour in 1200mm high above adjoining finished surface level and have 900mm non finishes.
accordance with final colour selections to exposed surfaces. climbing zone as specified in pool legislation.
Refer to Rockcote for full coating system details. Provide 1 2 3 4 5 6 7 8 9 10 11
Emer-clad waterproofing membrane and drip groove to u.s of
Formed concrete awning to be in accordance with structural
soffit. 7 200 5 690 1 710 7 490 7 105 7 105 7 490 1 710 5 690 7 200
engineers design and detail. Provide Rockcote acrylic render
system with sponge finish and painted with selected colour in
Timber framed trussed roofs to be in accordance with 9 575 9 575 7.21 m
9 416 top of roof top of roof
accordance with final colour selections to exposed surfaces.
engineers design and detail. Provide 0.42mm top of roof Refer to Rockcote for full coating system details. Provide Emer-
COLORBOND® steel BlueScope LYSAGHT CUSTOM 5.0° 5.0° 8 895 5.0° 5.0° clad waterproofing membrane and drip groove to u.s of soffit.
ORB® roof sheeting to be fixed in accordance with 8 650 top of roof beam 8 650
6 000 top of roof top of roof
manufacturers specifications.
8 300 street boundary setback 8 300
Ceiling
Concrete block wall to be in accordance with structural
engineers design and detail. Provide Rockcote acrylic render 7 155
system with sponge finish and painted with selected colour in rear boundary setback
2 700
accordance with final colour selections. Refer to Rockcote for
full coating system details.
5.0° 5.0°
5 600 5 600 ffl
First floor
6.79 m
4 480
top of bin store
U1 U2 U3 U4
3 100
2 500 2 500 ffl
Ground floor
1 500
typical ground level
Powder coated aluminium screen/fence. Bin store & wash bin area to have powder coated aluminium
sliding screen panels.
Concrete driveway and parking to be in accordance structural engineers design and detail.
Driveway to comply with AS2890.1. Provide new crossover in accordance with local authority Internal eave gutter to hydraulic engineer
regulations. Driveway grades to be in accordance with AS2890.1. Driveway to in selected design and detail.
exposed agg. concrete blend with tool joints as detailed, provide slip resistant clear sealer 1 2 3 4 5 6 7 8 9 10 11
coat to entire driveway and carport, applied in accordance with manufacturers specifications.
Formed concrete roof to be in accordance with structural engineers design and detail.
Concrete block wall to be in accordance with structural Provide Rockcote acrylic render system with sponge finish and painted with selected colour
engineers design and detail. Provide Crackenback stone in accordance with final colour selections to exposed wall surfaces. Refer to Rockcote for
facing by Eco outdoor. full coating system details.
Southern Elevation
S 1:100
/Users/benthornton/Docs/Cadfiles/2015 - HRS Developments/Archicad/
06052021/2015.pln
Braeden Constructions Pty Ltd
Mobile: 0418 505 117 project Attached Residences lot no. 1&2 DA05 Revised DA issue 7/5/21
project number
for HRS Developments Pty Ltd plan no. RP 72986 DA04 Revised DA issue 6/5/21
2015
braedenconstructions.com.au DA03 Revised DA issue 10/3/21
[email protected] 30-32 James Street drawn BT
P2 Preliminary issue 25/2/21
drawing number
Document Set ID: 21499551 QBCC: 1017247 at Noosaville scale (A1) 1:100 Rev Details Date 09 DA05 © Braeden Constructions Pty Ltd