Original PDF page 5, section 2. The text section number identifies this passage in the reader.
Concrete Timber fence
Timber fence
RL 14.21m
LOT 13 = 273.43 m2
Timbe
SW Field Inlet:IL: 3.365Type: 150 PVC
Sewer MH:IL: 2.382Type: 225 PVC
r fence
14.78
d
SW Field Inlet:IL: 3.355Type: 150 PVC
Sewer MH:IL: 1.946Type: 225 PVC
COMMON PROPERTY = 574.23 m2
14.77
LOT 08 = 185.23 m2 Concretedriveway
2.82
2.90
14.67
2.77
110SP106085
2.84
14.69
108SP106085 2.71
169°22'35
169°10'55
20.514
25.007
"
"
349°20'25
LOT 03 = 255.80 m2
20.055
14.80
Concrete
"
footpath
2.61
LOT 09 = 214.21 m2
Edge of bitumen
2.77
14.84
H
14.59
T30
LOT 14 = 273.31 m2 SW Field Inlet:IL: 6.668Type: 150 PVC
Site Benchmark
EMT XSP106085
Nail in Concrete
RL 14.18m
14.85
EMT WSP106085
14.93
T33
Site Benchmark
Nail in Concrete
RL 7.7m
Traffic Island
14.60
Kerb
MH
349°20'25
LOT 04 = 266.29 m2
T35
5.049
LOT 10 = 198.72 m2
3.292
T24
268°23'
T34
"
14.84 15.07
14.62
T25
Bitu 14.47
men
14.64
Sewer MH:(Unable to open)
Concrete
14.97
14.53
14.81
109SP106085
T27
.45 "
11 4'30
169°22'35
0
14.66
°0
20.189
31
"
14.78
T29
T26
g
15.02
rkin
g
markin
LOT 05 = 353.66 m2
ma
Line
LOT 11 = 321.12 m2 LOT 15 = 444.49 m2
Line
14.63
T28
path
l
nne
e foot
14.97
cha
b and
Concret
Ker
0"
4'3
75
°0
6.5
31
T45
T46
d
of roa
T50 T49
Bitum T51
ne
en 14.47 T48
ntreli
T47
14.88
Ce
43.173 50.342
268°10'50" 268°10'50"
Timber fence
75RP71151 75RP71151
14.77
Sewer Line: US IL: 10.863Type: 150
RCP
107SP106085
14.65
Lot Plan
1:500
DETAIL SURVEY NOTES
METADATA Client: Devtex Nominees Pty Ltd SUBSURFACE UTILITY INFORMATION (SUI) - AS5488
B+B Reference: 241259 Quality A (QL-A) Horizontal and Vertical Accuracy is 50mm Information has the highest level of accuracy. To achieve this quality level the underground utility would ideally be surveyed when it is initially installed.
Project Manager: Corey James QL-A can also be achieved through non-destructive excavation techniques (Potholing); however, where the whole line segment cannot be verified by line of sight, QL-A is not given to the line segment between validated points.
Project Description: 73-77 Eumundi Noosa Road, Noosaville Quality B (QL-B) Horizontal Accuracy is 300mm and Vertical Accuracy is 500mm Information is collected as a relative subsurface feature location by means of utility tracing or through physical measurements that do not satisfy the spatial tolerance of QL-A data. Typical methods of
Project Address: 73-77 Eumundi Noosa Road, Noosaville, Qld, 4566 service location for QL-B services include electromagnetic location, acoustic pulse equipment, sondes or flexi trace or ground penetrating radar. These methods of service location are often affected by soil conditions and interference from electromagnetic fields and generally do not
RP Description: 1-3 & 48-50/SP298783 account for multiple conduit banks. The minimum requirement for QL-B is relative spatial position.
Horizontal Datum: MGA Derived GNSS (CORS) Quality C (QL-C) Horizontal Accuracy is 300mm Quality level C is assigned to subsurface utilities information which is extracted from GIS databases and/or other existing records and is adjusted to correlate with surveyed surface installations. QL-C data has no vertical information and is
Vertical Datum: AHD Derived ((PSM53205)) an approximation of service position. The minimum requirement for QL-C is relative spatial position.
Coordinate Origin: Arbitrary ((NE Cor Site)) Quality D (QL-D) Indicative location only. Utility information is extracted from GIS databases, existing records or site inspections and is positioned using boundary offsets or scaling. Quality level D is the lowest of the four quality levels and only indicates the presence of a service.
Geodetic Datum: GDA2020 (Zone 56) Detection disclaimer: Where Quality Level B or lower has been used to show the location of services a non-destructive dig process should be carried out to identify the service and confirm the positions and heights where these are critical. Although all reasonable effort has been made in
Coordinate System: Plane 1:1 locating and mapping the underground services, the complete extents of this utility survey information cannot be guaranteed.
Cadastral Meridian swing: + 8°58'38" RP71151 BOUNDARY DISCLAIMER Unless otherwise noted, Cadastral information contained in this dataset or shown on associated plans is vide title and subject to definition by formal Cadastral Survey. As such it is approximate only and should not be used for Design and/or construction in
Date of Survey: 15/08/2024 close proximity to the boundary. Model names make a clear delineation between Surveyed Cadastral Boundaries (BDY-SURVEYED), Title Boundary information (BDY-TITLE), Proposed Boundaries (BDY-PROPOSED), and boundaries created from the Digital Cadastral Database
Height Origin RL:13.595m (BDY-DCDB).
B L A C K
LOT PLAN THE AVALON
W O O D
DA1.05
Scale Project No. Date Revision
28/01/2025 D For Devtex Nominees Pty Ltd
1:500 @ A3 202507
a r c h i t e c t u r e & d e s i g n 73-77 Eumundi Noosa Rd + 2C/2D/2E Starboard Ave, Noosaville QLD 4566
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.