Council archive · source document
Stockwell RFI Response Letter Final 22.12.21 · MCU21/0175
outcomes as the Stormwater Management Plan appears to identify low vegetation requirements in the easement which will not provide adequate screening to disguise the design of the bio-retention basins. Information Required: Update application documentation to ensure the bio-retention basins are adequately screened and meet the Landscaping Code outcomes in particular amenity and provide justification. Our Response: Please see the attached Appendix B – Landscape Concept Design Package by Place Design Group. Drawing Number LCP11 highlights the plant palette of native bush shrubs to screen the proposed bio- retention basins. Further, the following comments are provided within the attached Appendix D – Landscape Code Response Letter by Place Design Group. “All WSUD basins proposed are to be fully planted out with shrubs (to screen retaining walls) and grasses between 6- 8/sqm (1-1.5m tall) to ensure an integrated landscape solution with the front entry buffer landscaping. Tubular balustrades have been provided for additional safety to vehicle car park side, to be screened with shrubs from the entry road. Basin 3 is proposed to have a landscape batter to the southern boundary to integrate into the adjacent planting. Once completed the WSUD devices will look and feel integrated into the buffer landscaping.” Council Item 14: Landscape Concept Design Package The 10m wide vegetation covenant is briefly mentioned within the Development Application Planning Report however it is not included within the Landscape Concept Design Package provided. Information Required Update the Landscape Concept Design Package to highlight the extent of the vegetation covenant and identify strictly no disturbance. Additionally ensure detail is provided on how the covenant will be protected during construction and following construction i.e., fencing etc. Our Response: Please refer to the attached Appendix B – Landscape Concept Design Package by Place Design Group. Drawing number LCP2 highlights the extent of the vegetation covenant to the east and south of the site being fully retained with no disturbance.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Stockwell RFI Response Letter Final 22.12.21.pdfRelated documentApplication case desk ↗
About this file
- File size
- 708 KB (small file)
- File type
No other editions are linked here.