2402 - CD 1.05 Revegitation Plan-CD 1.05 Revegetation Plan 01
Plans and drawings: the text below has words only, no drawings.
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
proposed
water tanks x3
proposed pump
N
house, 4.0 x 4.8m
align with contours
104
108
Pump
16
106
House 19.08ha
102
16 10
0
19.08ha
98
94
96
108
"
'40
19
1.
11
8° 7
29
2154.8
71
34 3
106
2.
3. 3.3
11
11 11
Pool Shed
Ex Pool 92
0
.2
1
.4
91
2
105°
91
1
.4
3
.6
92
8 0.5
90
26
8
.6
.1 1.1 9
83
6
24.4 '20"
9
59
91
4.
5 .6
.
4.
90
11 90
11
91 9
85
9
5
.1
4
16
61
91
.4
61
0
90
4.
4.
.5
11
11
90
27
.
91
0
5
2
.7
.7
.3
90
90
91
PVC Pipe
19.08ha 92
.0
9 Top 92.06
79
69
.
.
91
91
47
92
"
.
proposed
91
30
'20
.
91
7 .99 .93 2
91 9 92.4
4° 6
outdoor
21 2.53
19
7
.5
1
91
6
.0
living Ac store 92 .8
8
.4
9
91
92
pro
pa pos
co del b ed
95 .74
8
7
urt al
95 .75
.0
.0
2
.1
94
95
94
2
95
l
.1
Ex House
43
10
9.
pro
10
Ga
6
gy pos
te
m e d
31
1.
11
29 .5
2
5. 95
EJ 11
1
.5
95
Ga
te
7
.5
95
114
S
.18
Septic
proposed EJ
10 carport
8 Ex Office
Emt CE
E
3
71
5.
51
11
.
95
E
IO Ga
114.69
te RP167252
S
E
Septic
94
E
SP20E
8256E
E
E
110
propsed guest
E
Unde
accommodation
E
rgrou 5 "
building See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 section
Section 2
E
42 6'40
nd
110 .
90 °2
E
2
23
E
SW
96
6
.1
E
97
45
E
1.
11
5
.5
Marker Post
98
98
108
E
35
4.
11
Pump
existing stables building
E
to be removed
E
106
E
01
95
6.
2
5.
100 99.9
11
11
E
104
E
Carpo
115.03
EJ
E
19
rt
3
5.
8
0.
28
11
10
5.
11
E
89
0.
17
10
102
5.
28
11
E
5.
11
102
106
5 "
E
. 42 6'40
108
90 °2
E
104
green fill indicates landscape re-vegetation area
104
110
2
23
102
adjacent to and within drainage swales.
E
112
44
4.
106
11
E
Lomandra and other native ground covers
E
114
subject to approval by NSC.
E
Re-vegetation Plan - House Area 1:500 @ A1
256 E
Planting to further detail as per landscape
SP208 E
8
10
0
architect's docmentation (to be supplied
.9
15
E
following approval)
E
115.25
E
EJ
E
po box 603 noosa heads qld 4567 project issue date details drawing proj no.
Alts. and Adds. + New Buildings
ph 07 5455 4808
A 20/08/2024 for certifier schematic design
2402
email [email protected]
Revegetation plan 01
abn 85 114 469 395
reg no 002195 116 Hayward Rd Lake Macdonald 0 5 10 15m 25m
dwg no.
CD 1.05A
This drawing is subject to copyright and cannot client Scale 1 : 500 @ A1
be reproduced in any medium without the written
permission of Tim Ditchfield Architects R&L Delaney