Planning Report - 13 Eumundi-Noosa Road, Noosaville QLD 4566 - Dual Occupany
GPC
5.6.2 Side Boundary Setback
Acceptable outcome AO12.1 of the Medium density residential zone code prescribes a minimum side
boundary setback of:
• 1.5m setback up to a wall height of 4.5m
• 2.0m setback between a wall height of 4.5m – 7.5m
• 2.5m where above a wall height of 7.5m.
The proposed development contains the following side boundary setbacks which partially do not comply
with acceptable outcome AO12.1:
Lot 1 Dual Occupancy
• Varying setback of 0.875m – 2.5m up to a wall height of 4.5m along the eastern boundary
• 1.0m setback up to wall height between 4.5m – 7.5m along the eastern boundary
Lot 2 Dual Occupancy
• Varying setback of 1.0m – 1.4m up to a wall height of 4.5m along the western boundary.
It is important to note that the setbacks as mentioned above vary along the wall length and therefore non-
compliance is only limited to certain sections along the eastern façade of the Lot 1 dual occupancy and the
western façade of the Lot 2 dual occupancy. Further, all other setbacks comply with the provisions of the
Medium density residential zone code, noting that the setbacks between the dual occupancy units are
considered to be internal.
An assessment which demonstrates compliance with correspondence performance outcome PO12 is
provided in the table below.
Performance Outcome PO12 – GPC Assessment
Medium Density Residential Zone Code
Buildings and structures are designed and
sited to:
(a) provide a high level of amenity to Lot 1 Dual Occupancy
users of the
The reduced side boundary setback along the eastern side
subject site and adjoining premises,
boundary adjoins an access handle which accommodates
including provision of visual and
vehicle movements to the Noosa Sea Scouts facility at the
acoustic privacy;
rear of the site. Accordingly, amenity impacts as a
consequence of this reduced eastern side boundary setback
is considered minimal, noting that the eastern façade of the
building contains significant building articulation and
landscaping for the full length of the boundary.
Lot 2 Dual Occupancy
The reduced side boundary setback which varies between
1.0m – 1.4m along the western side boundary relates to the
ground level of the dual occupancy unit and will be screened
by landscaping for the full length of the boundary. The
second level contains a side boundary setback of 2.5m-3.4m
which exceeds the planning scheme requirement.
Accordingly, visual and acoustic privacy impacts are
considered negligible.
13 Eumundi Noosa Road, Noosaville QLD 4566 | 12
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.