Planning Report - 13 Eumundi-Noosa Road, Noosaville QLD 4566 - Dual Occupany

of 145

Page text read automatically using OCR, there may be inaccuracies

 Performance outcomes                                        Acceptable outcomes                               Response
           4. maximise         opportunities       for runoff, including hydrocarbons, entering the
              infiltration of rainwater on-site; and stormwater system and watercourses.
           5. minimise     contaminated    runoff
                                                                                                 Not applicable
              entering the stormwater system and AO11.4
                                                                                                 The proposed development does not include open
              a watercourse.                      Canopy trees are protected from vehicle damage
                                                                                                 car parking spaces.
                                                  by providing adequate sized garden beds.
                                                                                                                 Not applicable
                                                             AO11.5
                                                                                                                 The proposed development does not include open
                                                             Plants with thorns, fruit or berries are avoided in
                                                                                                                 car parking spaces.
                                                             car                                          parks.

                                                             Editor's note— Refer to Figure AP3-5B
                                                                                                             Not applicable
 Services,      utilities     and      infrastructure        AO12.1
                                                                                                             The proposed development is not located within
 PO12                                                        Vegetation planted within the easement of an
                                                                                                             proximity to overhead powerline infrastructure.
 Vegetation does not pose a risk to the safety or            overhead powerline or, where there is no
 reliability of services, utilities or infrastructure        easement, the area of influence of a powerline,
 including substations, overhead powerlines,                 has a mature height of no more than 3.5 metres.
 power poles and transformers, street lamps,
                                                                                                                 Not applicable
 stormwater catchment pits, and underground                  AO12.2
                                                                                                                 The proposed development is not located within
 services and utilities.                                     Vegetation planted within an underground
                                                                                                                 proximity to overhead powerline infrastructure.
                                                             powerline easement does not have a mature root
                                                             system in excess of 150 millimetres in depth and is
                                                             not located directly over the powerline.
                                                                                                           Not applicable
                                                             AO12.3
                                                                                                           The proposed development is not located within
                                                             Regardless    of    the      width   of   the
                                                                                                           proximity to overhead powerline infrastructure.
                                                             easement, vegetation adjoining easements must
                                                             be separated from the power pole or other




Development Application: 13 Eumundi Noosa Road, Noosaville              Noosa Plan 2020: Amendment 1                                       Effective date: 25/09/2020

Log in to download the original (Planning Report - 13 Eumundi-Noosa Road, Noosaville QLD 4566 - Dual Occupany.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.