Original source · versioned page text
Reference Document - MCU25 0060 (As Published)
Executive Summary This report details the results of a geotechnical investigation undertaken for a proposed residential development at 22/512 David Low Way, within The Dunes estate at Castaways Beach. The investigation comprised drilling of boreholes at three locations across accessible areas of the development footprint. This report summarises the results of our investigation and provides geotechnical recommendations regarding earthworks and footings, together with temporary and permanent basement retention. Architectural design drawings provided indicate that the development will comprise a three-storey building. Bulk excavations will be in the order of up to 3 m to 3.5 m deep and localised filling up to about 1.5 m high is anticipated. Excavations are expected to extend close to the site boundaries and therefore, some form of retention will be required. The subsurface conditions encountered in the boreholes are summarised as follows: ▪ Topsoil – comprising very loose to loose sand to depths of 0.1 m to 0.2 m below ground level (BGL); then ▪ Natural Sands – comprising poorly graded sands mostly being loose to medium dense to depths of between 1.1 m and 1.3 m BGL; then becoming medium dense and increasing to dense below depths of about 3.1 m to 3.8 m BGL in boreholes BH1 and BH2. No signs of groundwater seepage (‘springs’) were observed during our walk-over. Groundwater was not encountered in the boreholes at the time of investigation. Provided the recommendations within this report are adhered to, and subject to detailed design and construction of the footing and retention system by a suitably qualified and experienced RPEQ structural engineer, there should be a Low Risk to property from slope instability. Excavations through the existing soils should be achievable using conventional earthmoving plant (e.g. small or larger excavators with toothed buckets). Temporary unsurcharged cuts could be formed at 1V:2H in the very loose to loose sands, and at 1V:1H in medium dense (or denser) sand, for batters up to 3 m in height, provided groundwater seepage is not encountered and sands do not slough from the batter face as they dry out. It is expected that space restrictions will limit battering of temporary cuts on the site and so some form of retention system, such as sheet piles or contiguous reinforced concrete piles, will be required. These retention systems, which may have to be temporarily braced during construction, may also be designed to form the permanent basement walls. Footings for the proposed development and any ancillary structures (e.g. retaining walls) must penetrate through any unsuitable natural soils (i.e. very loose to loose sands) to found at least 0.5 m into medium dense (or denser) natural sands. Such materials were encountered in the boreholes below depths of between about 1.1 m and 1.3 m BGL (existing ground levels). High-level footings would be suitable in excavation areas where medium dense (or denser) natural sands are exposed at the subgrade level. Piled footings would be required if loose sand materials are found at or near foundation subgrade level. Given the sandy soil profile, where deepened footings are required, steel screw piles are considered to be a suitable foundation type. Due to the presence of loose sands, together with the close proximity of adjacent buildings, open bored piers or driven piles are not considered to be suitable for this site. Cast in place continuous flight auger (CFA) piles may also be suitable for both foundation and shoring piles provided a small rig capable of traversing the site can be sourced. Proposed Residential Development 25 August 2025 | 25038-001-Rev0 iii
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.