Performance Outcomes Acceptable Outcomes
and uses;
(b) do not unreasonably impact on the amenity enjoyed by (b) avoid reduction of sunlight to at least 40% of the private
users of adjoining or nearby premises, including privacy open space areas of any adjoining residences to less
and access to sunlight. than 2 hours between 9:00am and 3:00pm on any day of
the year;
Editor's note—Provisions for sill height, glazing, screening and (c) incorporate fencing, landscaping and screening to
window openings are to improve the residential amenity for mitigate impacts on adjoining residential uses.
occupants. Thermal performance requirements are contained in Editor's note—refer to figure AP31A and figure AP32A
Queensland Development Code MP4.1 Sustainable Buildings.
Energy efficiency requirements are contained in the National AO20AO21.2
Construction Code. Dwellings and visitor accommodation units established as part
of a mixeduse development incorporate suitable noise
attenuation measures to reduce amenity impacts from business
or entertainment uses.
AO20AO21.3
Transparent doors and windows are designed and located so
they do not directly face transparent doors or windows or the
private open space areas of other dwellings or accommodation
units within 10 metres;
AO20AO21.4
Where windows, balconies, terraces, verandahs or decks
overlook or have the potential to overlook the private open space
of nearby properties or view into habitable room windows within
10 metres—
(a) windows have a sill height of not less than 1.7 metres
above finished floor level;
(b) windows and other openings are permanently screened
to a minimum height of 1.7 metres to avoid overlooking;
(c) windows and doors use translucent glazing to obscure
views; or
(d) windows or balconies are offset by 45 degrees or more.
Editor's note—refer to figure AP31C
AO20AO21.5
Screens, pergolas, landscaping and architectural design of
balconies are used to screen the ground floor private open
space of dwellings from separate upperlevel dwellings.
AO20AO21.6
Permanently fixed external screening devices complement the
building's external materials and finishes and may incorporate
solid translucent screens, shutters, perforated panels or
trellises which have a maximum of 50% openings.
Editor's note—refer to figure AP31B
PO21PO22 AO21AO22.1
Development, including mechanical plant, vehicle manoeuvring, Communal outdoor recreational facilities including swimming
commercial kitchens, and communal outdoor recreation uses: pools, spas and sports courts are:
(a) do not have an adverse effect on the amenity enjoyed by (a) setback at least 12 metres from the boundary of land in a
users of adjacent or nearby premises through emission residential zone and screened by a 5 metre wide buffer
of noise, light, fumes or smoke; densely planted with trees and shrubs including species
(b) do not cause unreasonable disturbance to local fauna from 1 metre to 8 metres in height; or
through light or smoke emissions. (b) located internally to the arrangement of buildings on the