Roofing:

Corrugated steel,zincalume finish, screw fixed to battens

as recommended by Roofing Manufacturer.

Battens:

75 x 38 how. at 1000 CRS internally, with an extra batten

at perimeter, ridge and hip lines (i.e. 500 CRS.) !

150 x 38 F14 how,

Fix with one fuly nailed framing anchor

at each end.

175 x 50 F14 how, hanging beam

100 x

rafters at 1200 CRS

100 hew. po

100 x 38 F14 how. rafters @ 900 CRS
Fix with framing anchor at each end.

1
150 x 50 F14 how. lintel

a

 

 

ee

Tt
Twin 100 x 3B how. ties

 

 

 

 

 

 

 

 

 

 

  
   

Clerestorey windows

 

 

 

 

 

 

 

 

 

 

 

  

150 x 38 (thicknessed) F14 hiw. rafters ® 600

 

 

 

 

 

 

 

 

 

 

 

  
   

 
 

  

 

 

 

 

 

 

 

 

  

 

1
Ie
; 1
a | F8 Oregon bean CRS - Fix with one fully nailed framing
i I anchor at each end.
u/s Ceiling joists FF f i i
. iY = / 150 x 75 ZnAl Quad Guttering
13mm plasterboard V4 10mm plasterboard fixe 13mm plasterboard CT SO
fixed direct to | direct to 100 x 38 studs fixed direct to SO x 150 F14 how. top
u/s/ joists Yj i at 600 CRS u/s of rafters - Plate fixed to bond beam
. with M12 bolts at 1500
o timber te | min. CRS
w trellis : .
o
° N i
i
i par
I |
f.1. Top of Slab Lf i
Compressible joint? PA
Filler 7 : (A
i 7 <-—— Sheet metal weatherhood. sees se
i \ awk j SeGos A Sings COM ei
i b 190 thick concrete Suspended reinforced concrete slab
. o Y block walls “ (See Engineer's details) : i
S | Reinforce as . NTs OF THE BUiLE
& VY specities Drg.4 (F-80 thick concrete block (non 1.b.) Si nAHD BUILDING BY. aS 3
. i V Construct after upper floor slab PF ! BY-LAWS AND ANY CONDITIONS SHOWIN ON THE
i Z has been stripped ArPROVED PLANS AND BUILDING PERMIT.
i
4 q UNDER NO CIRCUMSTANCES MAY THE PL 1
“ SPECIFICATIONS BE D=pAnten es ee
x WRITTEN APPROVAL OF Ti: Shit se
= T SURVEYOR, me ss
Ba =

 

 

Reinforced Concrete Footings:

 

 

400 wide x 800 (min) deep
2012 t & b. R6 ligs @ 600
€0 cover

 

 

 

SPIRE BUILDING SURVEYOR

100 thick reinforced concrete slab on ground:

CRS

F72 T 30 Cover. Waterproof membrane

  

BUILDING PERMIT No.. Le

eens toa

DATEDS.2 7.2 19 FE

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

enremmegpeeceepeeagger 8 9st

7

| Scale evision Details: | By:] Date: pee Stage: "Drawing: te: aa a 3
o J DWELLING UNITS a _ wee fl 2... SIM oe
HL: SO____ |. late Take S| Fewantin |” Working ~ section A 16 Jan 1985" Suite 19 Tewantin Plaza a
Drawings - . ae Tewanth Qld 4565 __ — -
Tel: (071) 498 280 _

 

 

 
Log in to download the original file

Appendix B - Existing Approval Documents.pdf · 11.9 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.