  Landscape Intent                                              Planting Palette                                                         Site Character




                                                                                                                                                                                                            Deisgn Intetnt & Suggested Plant Palette
                                                                                                                                                                                                                                                       139 Eumundi Road
                                                                Trees
 The landscape design approach for ”Empirica”, at
 139 Eumundi Road Noosaville, centres on the intent to          Botanical name                        Common Name
 deliver a modern high presentation service facility with a
 predominant focus on semi advanced Native Subtropical          Cupaniopsis anacardioides (A)         Tuckeroo
 Landscaping. Soft landscape areas are preferentially           Banksia integrifolia (B)              Coastal Banksia
                                                                Elaeocarpus eumundi (D)               Eumundi quandong
 located to site perimeters where they offer separation from
                                                                Syzygium luehmannii (C)               Lilly Pilly
 high traffic roadways and site users.                          Xanthostemon chrysanthus              Golden Penda
                                                                                                                                                                    Photo 1
                                                             Shrubs
 Among the criteria achieved in the landscape design are the                                                                                                                                      Photo 2
 following:-                                                 Cordyline fruticosa rubra (E)            Red Cordyline
                                                                Melaleuca ‘Claret Tops’ (F)           Melaleuca Claret Tops
 ʄ 3 metre wide planting areas on average to all available   Groundcovers and Climbers
   frontages.
 ʄ Tree planting expected to achieve 50% screening of        Lomandra hystrix (I)                     Slender Mat Rush
   buildings at 5 years.                                     Macrophytes - Biobasin Planting
 ʄ Greater than 1 tree for 6 carparks.
 ʄ Bio-retention basins fringed and augmented with perimeter Juncus krausii (G) (15%)                 Salt Marsh Rush
   tree plantings (clear trunked when required).             Ficinia nodosa (H) (15%)                 Knotted Club Rush
                                                             Lomandra hystrix (I) (70%)               Slender Mat Rush
 ʄ Species selected to be representative of the best of
   commercial landscapes within the Noosaville locality.     Planting Distances From Services
                                                                Min. DIST.                            Service
                             -                                  3m                                    Power poles
                                                                3m                                    Fire hydrant




                                                                                                                                                                                                                                                       Noosaville
                   NOOSA COUNCIL                                9m                                    Street lights
                                                                2m                                    Stormwater pit
                   APPROVED PLAN                                1m                                    Other services
               MCU14/0102.02 OPW15/0051                         Approx.DIST.                    Service
                     23 OCT 2015                                0.9m                            Street trees from kerb
                                                                2.5m                            Street tree spacings for multiples
Trees




                                                  A                          B                   C
Shrubs




                                                                                                                                                                                                                              scale
                                                                                                                                                                                                                   not to any scale
                                                                                                                                                                                                                    project number
                                                                                                                                                                                                                             14141
                                                                                                                                                                                                                   drawing number
                                                  E                                              F                                   D                                                                                    SD-03 [F]
                                                                                                                                                                                                                               date
                                                                                                                                                                                                                        2015/08/05
Groundcovers




                                                  G                                              H                                   I   200L Elaeocarpus eumundi             Photo 1   Photo 2
Log in to download the original file

SUPERSEDED MCU14_0102.02 - Approved Plans.pdf · 5.3 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.