SPECIFICATION NOTES
THIS DRAWING IS TO BE READ IN CONJUNCTION
GENERALLY WORKMANSHIP SPECIFICALLY WITH GENERAL NOTES ON DRAWING No. A000.
REFER TO DRAWING A000 FOR SCHEDULES.
THESE NOTES AND DETAIL DRAWINGS APPLY TO THE NOMINATED BUILDER AND ANY SUBCONTRACTORS EMPLOYED BY THE SAME, AND
THE CONTRACTORS SPECIFICALLY NOMINATED BY THE CLIENT. JOINERY GENERALLY
FIGURED DIMENSIONS ARE TO BE TAKEN IN PREFERENCE TO SCALE. ALL DIMENSIONS ARE TO BE VERIFIED BY THE BUILDER AND ANY JOINERY SHALL BE OF THE HIGHEST QUALITY AND FINISH. CORNERS SHALL BE MITERED TO VISIBLE BULKHEADS, SHOP FRONT
ERRORS OR DISCREPANCIES ARE TO BE CLARIFIED BY THE BUILDER TOGETHER WITH THE CLIENT AND/OR DESIGNER BEFORE WORK PORTALS ETC.
COMMENCES, MANUFACTURE OR INSTALLATION.
THE FITTINGS AND FIXTURES SHALL BE INSTALLED AS SPECIFIED ON THE PLANS.
APPROVED DRAWINGS BUILD ALL COMPONENTS SQUARE AND INSTALL PLUMB. USE MATERIALS IN SINGLE LENGTHS WHERE POSSIBLE. IF JOINTS ARE
NECESSARY, MAKE THEM OVER SUPPORTS.
ALL WORKS MUST BE CARRIED OUT IN STRICT ACCORDANCE WITH THE LESSOR'S APPROVED DESIGNS, AURORA DESIGN PTY. LTD.
PLANS AND ANY RELEVANT PROVIDED CONSULTING ENGINEER'S PLANS, DETAILS & SPECIFICATION, THE LESSOR'S AND COUNCIL WHERE 2 PAC FINISHES ARE SPECIFIED TO LARGE PANEL SIZES THE JOINTS ARE TO BE EXPRESSED IN THE FORM OF A 'V' GROOVE
REQUIREMENTS. JOINT OR OTHER AS SPECIFIED ON THE DRAWINGS. ALL JOINTS ARE TO BE EQUALLY SPACED UNLESS NOTED OTHERWISE.
A COMPLETE SET OF LESSOR'S APPROVED DRAWINGS SHALL BE KEPT ON SITE AT ALL TIMES. USE FASTENERS TO TRANSMIT THE LOADS IMPOSED AND TO ENSURE THE RIGIDITY OF THE ASSEMBLY WITHOUT SPLITTING OR
OTHERWISE DAMAGING THE SHEETS.
REGULATORY REQUIREMENTS DO NOT USE VISIBLE FIXINGS, EXCEPT INSIDE NON GLAZED CUPBOARDS AND DRAWER UNITS (IN WHICH CASE USE PROPRIETARY
CAPS TO CONCEAL FIXINGS), UNLESS NOTED OTHERWISE.
THE BUILDER SHALL CONFORM WITH ALL THE REQUIREMENTS OF THE CURRENT BUILDING CODE OF AUSTRALIA, RELEVANT
AUSTRALIAN STANDARDS AND THE LOCAL COUNCIL REQUIREMENTS. THESE STANDARDS SUPERSEDE ALL DETAILS AND NOTES ON THE USE ADHESIVES TO TRANSMIT THE LOADS IMPOSED AND TO ENSURE THE RIGIDITY OF THE ASSEMBLY, WITHOUT CAUSING
DRAWINGS WHERE APPLICABLE DISCOLORATION OF THE FINISHED SURFACES.
INSTALL GLAZING IN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA AND AUSTRALIAN STANDARDS AS1288 & AS2047 SCRIBE BENCH TOPS, SPLASH BACKS, ENDS OF CUPBOARDS, KICKBOARDS AND RETURNS TO FOLLOW THE LINE OF THE
STRUCTURE & MALL.
TENDERING FINISH ALL EXPOSED EDGES OF SHEETS AS CONFIRMED BY DESIGNER.
THE TENDERERS SHALL VISIT THE SITE TO DETERMINE THE EXTENT OF DEMOLITION REQUIRED FOR THE NEW WORK, REQUIRED CUPBOARD SHELF AND DRAWER UNITS ARE TO BE CONSTRUCTED OUT OF THE SPECIFIED MELAMINE COLOUR BOARD. SCRIBE TO
TEMPORARY STRUCTURES, NEW SUPPORTING ELEMENTS ETC. AS REQUIRED BY THE SPECIFIED WORKS. FLOOR AND SECURE TO WALL TO PROVIDE A LEVEL FINISH.
ALL TENDERERS MUST VISIT THE SITE AND ASCERTAIN FOR THEMSELVES THE NATURE AND EXTENT OF THE WORK AND FACILITIES FOR SUPPORT ADJUSTABLE SHELVES ON PROPRIETARY PINS IN HOLES BORED AT 32mm CENTRES VERTICALLY.
THE CARRYING OUT THE SAME. THEY SHALL SATISFY THEMSELVES AS TO THE CONDITIONS, ALLOWED WORKING HOURS, DIMENSIONS,
POSITION OF SERVICES AND THE LIKE. THEY SHALL FAMILIARISE THEMSELVES WITH THE SPECIFIC REQUIREMENTS OF THE LESSOR, PROVIDE ADJUSTABLE CONCEALED METAL HINGES AND METAL RUNNERS AS SPECIFIED.
INCLUDING BUT NOT LIMITED TO INSURANCES, ACCESS, MATERIAL DELIVERY AND STORAGE, RUBBISH REMOVAL AND THE LIKE.
TENDERERS WILL NOT BE ABLE TO CLAIM EXTRAS UNFORESEEN THROUGH LACK OF HAVING TAKEN THESE PRECAUTIONS.
STRUCTURAL DESIGN AND CERTIFICATION
HOARDING AND PROTECTION OF THE SITE THE BUILDER SHALL ENSURE THAT ALL ITEMS DETAILED, SPECIFIED AND INSTALLED ARE SUITABLE FOR THE PURPOSE THEY ARE
UE
INTENDED FOR AND STRUCTURALLY ADEQUATE TO SUPPORT THE USAGE & LOADS.
THE BUILDER SHALL PROVIDE A HOARDING TO THE SITE WHEN DIRECTED BY THE CLIENT AND / OR LESSOR. THE HOARDING SHALL BE
S
IS
TO THE SPECIFICATION OF THE LESSOR. ALL STRUCTURAL ELEMENTS, BULKHEADS, GLAZING SUPPORTS AND THE LIKE SHALL BE DESIGNED TO SUPPORT THEIR OWN
WEIGHT AND THE LOADS IMPOSED. ON COMPLETION THE BUILDER SHALL PROVIDE A STRUCTURAL ENGINEERING CERTIFICATE
VAL
THE BUILDER SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL AREAS NOT INVOLVED IN THE CONSTRUCTION WORK AND ALL FOR THESE ELEMENTS.
RO
CARE SHALL BE TAKEN TO MINIMISE DUST AND DIRT TO THE SITE AND ADJOINING SITE, MALL AREAS AND THE LIKE. THE BUILDER IS
RESPONSIBLE TO RECTIFY IMMEDIATELY ANY DAMAGES THAT OCCUR TO THE PROPERTY AND SURROUNDING AREA. APP
RUBBISH REMOVAL
WORKMANSHIP GENERALLY THE BUILDER SHALL PERIODICALLY CLEAN UP THE PROPERTY AND REMOVE DEBRIS FROM THE SITE. ALL RUBBISH SKIPS AND THE
LIKE ARE TO BE POSITIONED IN ACCORDANCE WITH THE LESSOR AND/OR COUNCIL'S REQUIREMENTS. RUBBISH SHALL NOT
THE BUILDER SHALL LIAISE WITH THE LESSOR AS TO WHEN AND WHERE BUILDING DELIVERIES CAN TAKE PLACE AND WHERE THEY CAN INTERFERE WITH THE AMENITY OF ADJOINING PROPERTIES.
BE POSITIONED IN RELATION TO THE SITE.
ALL WORK IS TO BE CARRIED OUT IN STRICT ACCORDANCE WITH THE PLANS. ANY CHANGES TO THE APPROVED PLANS ARE TO BE
VERIFIED BY THE DESIGNER IN WRITING PRIOR TO MANUFACTURE, CONSTRUCTION AND/OR INSTALLATION. COMPLETION
02 APPROVAL ISSUE 18.04.17
IF THERE IS ANY DISCREPANCY BETWEEN THE PLANS AND SITE CONDITIONS THE BUILDER SHALL CONFIRM ANY REQUIRED CHANGES ON COMPLETION OF THE WORK, THE BUILDER SHALL CARRY OUT A FINAL CLEAN UP TO THE SATISFACTION OF THE CLIENT. ALL 01 CONCEPT DESIGN 04.01.17
TO THE DESIGN WITH THE DESIGNER PRIOR TO MANUFACTURE, CONSTRUCTION AND/OR INSTALLATION. DEBRIS SHALL BE STORED ON THE SITE AND DISPOSED OF AS SOON AS POSSIBLE. THE BUILDER IS TO CHECK ALL NEWLY
INSTALLED DOORS FOR SAFE AND EASY HANDLING. THE GLASS IS TO BE CLEANED AND THE SEALS CHECKED. AT THE REVISION DESCRIPTION DATE
ALL WORK IS TO BE CARRIED OUT BY LICENSED TRADES PEOPLE. COMPLETION OF THE WORK THE WHOLE SITE, INCLUDING AREAS NOT INVOLVED IN THE WORK ARE TO BE COMPLETELY CLEANED,
DAMAGED PAINT WORK TO BE RE-DONE OR TOUCHED UP USING PAINT FROM THE SAME BATCH AS THE ORIGINAL WORK.
ANY PORTION OF THE WORK NOT SHOWN ON DRAWINGS BUT WHICH IS NECESSARY FOR THE COMPLETION OF THE ENTIRE
CONTRACTUALLY AGREED WORK, SHALL BE UNDERSTOOD AS INCLUDED. ALL RELEVANT CERTIFICATES FOR STRUCTURAL ELEMENTS, BULKHEADS, WATERPROOFING, PLUMBING, ESSENTIAL AND
EMERGENCY SERVICES ETC. SHALL BE SUPPLIED TO THE CLIENT AT HANDOVER OF THE COMPLETED SHOP.
SPECIFICATION
ALL MATERIALS ARE TO BE OF NEW AND BEST QUALITY AND TO THE SPECIFICATION SHOWN ON THE PLANS UNLESS AGREED UPON BY
THE CLIENT/DESIGNER IN WRITING. THE BUILDER SHALL ENSURE THAT THE RELEVANT CERTIFYING AUTHORITY IS NOTIFIED OF THE COMPLETION AND ARRANGE FOR
PROJECT:
THE FINAL INSPECTION AT LEAST TWO DAYS PRIOR TO PRACTICAL COMPLETION. THE BUILDER SHALL RECTIFY IMMEDIATELY ANY
ALL WORK SHALL BE UNDERTAKEN AND CARRIED OUT IN A WORKMANSHIP LIKE MANNER IN ACCORDANCE WITH GOOD BUILDING
PRACTICES.
DEFECTS NOTED BY THE INSPECTOR WHICH PREVENT THE ISSUE OF AN OCCUPATIONAL CERTIFICATE.
NOOSA CIVIC SHOPPING
THE BUILDER SHALL INFORM THE DESIGNER OF THE PRACTICAL COMPLETION OF THE PROJECT AT LEAST TWO DAYS PRIOR. ON 28 EENIE CREEK ROAD
IT IS THE RESPONSIBILITY OF THE CONTRACTOR/S TO ENSURE THAT ALL SPECIFIED EQUIPMENT, FITTINGS ETC. (WHETHER SUPPLIED COMPLETION A DEFECTS INSPECTION WILL BE UNDERTAKEN BY THE CLIENT AND/OR THE CLIENT'S REPRESENTATIVE AND ALL NOOSAVILLE, QLD. 4566
BY THE CONTRACTOR OR THE CLIENT) WILL FIT THE REQUIRED SPACE AND TO REFER ANY DISCREPANCIES TO THE DESIGNER / CLIENT DEFECTS SHALL BE RECTIFIED PRIOR TO THE FINAL PAYMENT BEING RELEASED.
CLIENT:
PRIOR TO MANUFACTURE, CONSTRUCTION AND / OR INSTALLATION.
THE BUILDER SHALL PROVIDE COPIES OF CERTIFICATES, WARRANTIES, GUARANTEES, MANUALS ETC. FOR ITEMS INSTALLED ON STAR CAR WASH
THE SITE.
P.O. BOX 6212
THE BUILDER SHALL PROVIDE TO THE CLIENT KEYS OF ALL LOCKABLE DOORS, CUPBOARDS AND THE LIKE. ALEXANDRIA NSW 2015
A.B.N. 74 194 321 852 2015
SUITE 1105, 50 CLARENCE STREET, SYDNEY NSW 2000
T:9025 9905 F:9587 6179 W:WWW.AURORADESIGN.NET.AU
SCALE: DRAWING No.: REVISION:
PROJECT No.: 16-045
DATE: DEC. 2016
A001 02
These drawings have been produced using site information & dimensions
supplied by client. Do not scale drawing, use figured dimension. All
dimensions to be verified prior to starting any work. This document is for
information only. Aurora Design retains copyright and intellectual
property rights in all design and documentation it produces. Aurora
Design grants one express license to the client to use this document and
design for the intended purpose and site only. No other license is implied.
Aurora Design may revoke the license if any whole or part invoiced
payment is overdue. No part or in full of this document is to be copied
without the written permission of Aurora Design.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.