 Specific Outcome                                  Probable Solution                                                 Response
          population in persons multiplied by
          40m2.
 O14     For the Visitor Mixed Use Zone, the                 No solution provided.                                   R14 Not Applicable
         maximum gross floor area equals the
         allowable population in persons
         multiplied by 40m2, provided that the
         gross floor area does not exceed
         13,600m2.
 O15     For the Business Centre Zone,                       No solution provided.                                   R15 Not Applicable
         outside of the Mary Street/Thomas
         Street Precinct the maximum plot ratio
         is —
            a) 0.8:1 for site areas up to and
            including 2,000m2; plus
            b) 0.3:1 for the balance portion of
            the site area in excess of 2000m2.
 O16     For the Shire Business Centre Zone,                 No solution provided.                                   R16 Complies
         the maximum plot ratio for
         development within the following                                                                            Due to the size and scale of the subject site, the proposal
         precincts is —                                                                                              presents a minor alteration to the existing GFA and Plot
                                                                                                                     Ratio associated with the established Noosa Civic Shopping
           a) Precincts B1 and B2 combined-                                                                          Centre development.
           0.5:1;
           b) Precinct B3- 0.8;
           c) Precinct E1- 0.6;
           d) Precinct E2- 0.6;
           e) Precinct E3- 0.6, except for
           Industrial business uses;
           f) Precinct E4- 0.6; except for
           Industrial business uses;
           g) Precinct E5- 0.6, except for
           Industrial business uses;
           h) Precinct E6- 0.6;
           i) Precinct E7- 0.6;
           j) Precinct RES- 0.6; and
           k) Precinct REC/MU- 0.1.
 Flooding and drainage

 O17     Buildings and other works are            S17.1      For new buildings or structures or additions of more    R17.1 Not Applicable
         designed and sited to—                              than 50m2 gross floor area to an existing building or
                                                                                                                     Subject site is not flood affected.


December 2017                                             Cardno                                                       8
Log in to download the original file

Part B - Attachments A to D.PDF · 5.1 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.