 Specific Outcome                                Probable Solution                                                     Response
                                                          buildings, or can be seen from a street or other public
                                                          space.
 O27    Buildings and structures are designed    S27.1      Buildings or structures that are visible from a public     R27 Complies
        to minimise opportunities for                       street or laneway—
        vandalism.                                                                                                     Proposal incorporates artwork on blank walls, windows
                                                                a) avoid the use of solid fences and blank walls       primarily positioned above ground level and hard-waring
                                                                which attract graffiti. Where solid blank surfaces     materials. Refer to Attachment B for detailed proposal
                                                                are unavoidable, measures in the form of               plans.
                                                                landscaping, creepers, murals, vandal resistant
                                                                paint, etc are used;
                                                                b) use toughened glass, security screens and
                                                                other measures (but not including security shutters
                                                                that obscure the view of shopfronts) are used in
                                                                windows which are provided at ground level, to
                                                                deter break and enters; and
                                                                c) use hardy vandal proof materials and anti-
                                                                graffiti paint are used in the construction of
                                                                buildings.
 O28    Lighting of appropriate intensities is   S28.1      Lighting of appropriate intensities is provided which      R28 Complies
        provided to maximise safety.                        satisfies the requirements of Australian Standard
                                                            AS1158: Public Lighting Code, unless otherwise             Lighting can be conditioned accordingly.
                                                            specified in this Code;
                                                            AND
                                                 S28.2      External lighting of a graduated intensity is provided
                                                            which starts at a lower level of brightness at the
                                                            perimeter of the site and rises to a higher level at the
                                                            entrance to buildings or at the centre of the site;
                                                            AND
                                                 S28.3      Lighting is directed onto the site and away from
                                                            neighbouring properties;
                                                            AND
                                                 S28.4      Vandal-resistant lighting is used in public and publicly
                                                            accessible areas.
 O29    Public toilets are designed and          S29.1      Public toilets are located in high traffic areas;          R29 Not Applicable
        constructed to—                                     AND                                                        Proposal does not comprise public toilets.
          a) ensure the safety of all people                Features that may legitimise loitering, such as seating
          using them; and                        S29.2
                                                            or public telephones are not located within 20m of
          b) take advantage of informal                     toilet entrances;
          surveillance from adjoining uses                  AND




December 2017                                            Cardno                                                         6
Log in to download the original file

Part B - Attachments A to D.PDF · 5.1 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.