Appendix C - Code Assessment
Reconfiguring a Lot Code
Lot layout Table 9.5.1.3 Criteria for assessable development (part)
Performance outcomes Acceptable outcomes Assessment
Growth Management
Lot Layout
Site Responsive Design AO7.1 – Not Applicable
PO7 AO7.1 The site is not located in any of the zones mentioned.
Development provides for a lot layout and configuration of roads If located in the Low density residential zone, Medium density
and pathways that is responsive to:- residential zone, High density residential zone, Tourist
accommodation zone or Community facilities zone and intended
a) the setting of the site within an urban or non-urban for a residential use, any new lot is located outside the modelled
context; flood level of the 1% AEP (1:100 year ARI) water surface levels or
b) any natural environmental values present on, or where not modelled, above the highest known flood level.
adjoining the site;
c) any natural hazards affecting the site or adjoining land
such that the number of properties or persons at risk is AO7.2
not increased; Flood immunity for development areas is not achieved by filling AO7.3 – Complies
d) the terrain of the land, minimising the need for land below the 1% AEP (1:100 year ARI) flood level. Each lot has flood immune house site areas and will not require
earthworks; filling.
e) any places of cultural heritage significance or character
areas present on, or adjoining the site; and AO7.3
f) any important landmarks, views, vistas or other areas of All reconfigured lots on land subject to a constraint or valuable
high scenic quality present on, or able to be viewed feature identified on an overlay map contains a building AO7.3 – Complies
from, the site. envelope marked on a plan of development that demonstrates Proposed Lot 2 has been provided with a building envelope
that there is an area sufficient to accommodate the intended which appropriately addresses environmental features, flood and
Editor’s Note— Development of land affected by constraints purpose of the lot, that is not subject to the constraint or valuable bushfire constraints pertaining to the property. The building
shown on overlay maps will be subject to overlay codes feature or that appropriately responds to the constraint or envelope will comprise an area of approximately 6000m2 which
valuable feature. will be sufficient for the establishment of a future house site
including associated structures and effluent disposal areas.
AO7.4 AO7.4 – Not Applicable
New lots with a site area less than 4,000m² in area have
a slope not exceeding: The lots are greater than 4000m2.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.