Approved Plans MCU16/0120.01
Original PDF page 4, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn B
1 2 3 4 F
5 6 C
7
-
12.36
WD.602 WD.605 WD.603
NOOSA COUNCIL design group
2 2,870 4,280 2,750 6,200 2,750 3,900
1 6 .4 APPROVED
TE
16.05
PLAN LL:10.66 MH
building design + interior design
MCU16/0120.01 20 JUN 2018 57°43'
14.88
IL:9.71
35.827
EJ indicates line
16.38 of Plan of
16.24
Development (POD)
SC powdercoated alu.
13.27
10
barge flashing 13.47 awning under, ref. det.
CO AWN
MM to match roof 2M SETBACK
9.94
A +20.949 +20.949
A
BOX GUTTER BELOW
+ T.O.R RL 20.949 T.O.R RL 20.949 +
12.13 11.89
1,550
1,550
15.50 NGL UNDER RL 14.342 NGL UNDER RL 13.103 painted infill pergola, ref. det.
12.51
HEIGHT ABOVE NGL 6.607m CFC HEIGHT ABOVE NGL 7.846m
continuous from
B barge flashing to
MR1 6º wall cladding under
B
match roof
POOL BELOW
AWNING UNDER
16.00 14.63
7.43 11.25
H 1
MR1 6º
15
.16 12.38
MASTER
VA
13.86 powdercoated alu.
continuous from ENS 10.01
LL
CFC
BED awning under, ref. det.
5,280
5,280
EY
D RL wall cladding under D
/TW BELOW
GU
WD.604 BELOW DET-18.2
WD.604
TT
WD.710
ER
indicates line
of Plan of AWN
147°43'10"
6M SETBACK
Development (POD) 9.96
329°57'10"
9
SEWER EASEMENT
vertical awning blade
18.983
VERGOLA R1355
18.012
MR1 below, ref. det.
DRIVEWAY 13.32 ROOF (below) BELOW
Park R
6º
continuous from
BELOW CFC
wall cladding under
C 11.94 C
valley gutter, to match
OFFICE
1,700
1,700
WIR roof sheet and to eng. det.
indicates line
BELOW 10.14
BELOW of Plan of
DP +sprdr Development (POD)
DA STAIR s/s rainwater
8.64
A
D
verge flashing to head, to eng. det.
1,190
1,190
NGL UNDER RL 13.263 NGL UNDER RL 12.104
WD.601 match roof HEIGHT ABOVE NGL 7.686m BELOW HEIGHT ABOVE NGL 7.986m
RWH
WD.601
+ T.O.R RL 20.949 T.O.R RL 20.090 +
E E
DP +sprdr
TURN BAY +20.949 +20.090
E CFC barge flashing DP under E
BOX GUTTER BELOW
BELOW
1,880
1,880
WD.605 to match roof WD.605
continuous from
wall cladding under
12.43
14.04
F 13.22
10.84
10.35
F
6M SETBACK
ROOF (below) ROOF (below) ROOF (below)
11.80
2,400
2,400
BA
10.04
11.09
G 2M SETBACK
8.58 G
verge flashing
8
to match roof verge flashing
IL:7.02
indicates line to match roof
of Plan of
9.78
WM 12.80 11.98 11.04 Development (POD)
13.70
36.542 7.87
15.38 239°15'35" MH
11
:
0
ROOF PLAN
AB-REL AS BUILT RELAXATION 19.05.18 SF/LF/AB
12,750
14
8
LL
9
2,870 4,280 2,750 6,200 3,900 :7.
12
95 no. issue / amendment date initial
13
B F C client
SCALE 1:100 @ A3
1 2 WD.602 3 4 WD.605 5 6 WD.603 7 K & B MONAHAN
project
WALL LEGEND GENERAL LEGEND FLOOR FINISH LEGEND EXT. FINISHES LEGEND MONAHAN RESIDENCE
location
AS aluminium screen. CS concrete slab. GS garage slab. RWT rain water tank. Lot 27 Noosa Dunes
RC masonry blockwork RL 17.200 denotes finished floor level FT1 FT2 Indicates extent of TILE
RC pool shell/off form concrete + RL 17.700 denotes spot level
AL aluminium louvres, refer sched. DP down pipe. HWS hot water service. SBJ silicone butt jointed glass. ROOF PLAN
70 step denotes change in level C Indicates extent of CARPET ASD aluminium sliding door. DS driveway slab. HR1 handrail - (no refers to type). SP structural post, refer eng. W
90MM ext. timber frame SU INTE Lee Foster / director
p - 0424 620 247
Scott Falconer / director
p - 0422 483 159
NP R
Se
fw AFD aluminium framed door. FCA fibre cement awning. LPG LPG gas bottle. SF structural footing, refer eng. AT design group e - [email protected] e - [email protected]
ttin
denotes floor waste SUMMER H the aboda design group Level 2 1794 David Low Way Coolum Beach,
g5
90MM int. timber frame Indicates extent of TIMBER. trust *ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
pm
TF TD
x.00 fall denotes min fall requirement Indicates intended direction of TIMBER.
AFW aluminium framed window. FC fibre cement external cladding. MR1 metal roof - (no refers to type). TD timber deck. SUN PATH t/a aboda design group *BSA License -1175640 *www.aboda.com.au
Lx
+R
*This drawing is to be read in conjunction with Engineers Drawings & Reports
not a full height refer to +RL sun control battens, refer detail. fascia gutter. natural ground line. timber floor.
denotes hard wired smoke
alarm BCA 3.7.2 min
BA FG NGL TF Setting 5.30 pm N Rising (7am)
*Construction to comply with all relevant SAA & BCA Codes & standard Bldg
By-law 1975 & as amended.
*Copyright for design & drawings remain the property of the authors.
Indicates extent of GS DR Indicates extent CONCRETE
chs shs structural posts - refer 300mm from wall BAL1 balustrade-(no refers to type). FT1 floor tile - (no refers to type). NRG NRG board TFD timber framed door *Verify all dimensions on site prior to commencement of any works.
*These drawings are not to be used for scaling.
engineer.
FINISH CODE LEGEND masonry blockwork. parapet wall. timber cladding.
12.5º denotes direction of roof fall controlled fill to eng. det. scale as shown @ A3 issue
Ris
BLK fill PW TIM
in
drawing no.
g (6
D04 denotes door number
carpet fireplace patio slab. timber lining
AB
.30
C fire PS TIM2
WD.204
MR denotes metal roof denotes additional 'extent' information
am
W04
REL
)
denotes window number
JXX
denotes item and number. (xxxxxxxx) conc off form concrete flue flue kit PV photovoltaic cells. VER vergola.
refer to Joiner for details denotes finish, refer 1000
hc bib tap, cold water only XX
series drawings for schedule
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.