re |___- Est.1972 Engineers ct MANAGERS Covington | (( CONSULTING chy, Gully Pit at Driveway Entrance It is recommended that the existing gated side entry pit on Tristania Drive which conflicts with the proposed driveway entrance, be converted to a grated entry pit. The driveway crossover will need to be specially formed around this pit to ensure a smooth entry is achieved. The capacity of this pit will be reduced following the removal of the side entry component. Hence it is recommended that a new gully pit with a 2.4m wide inlet be installed immediately upstream of the new driveway crossover with a @375 RCP linkage pipe to the existing pit. This will more than compensate for the loss of entry capacity. The above information demonstrates how this proposal achieves Specific Outcomes 04 and 06 of the Driveways and Carparking code. If you have any queries relating to the above advice, please contact Mr. Peter Mathers of this office. Yours faithfully COVINGTON ENGINEERS JT tobbees Peter Mathers Managing Director Encls. \\Data\projects\Wob Files\1005 - 20-22 Tristania Drive, Marcus Beach -A Rigby\Correspondenceiletters\Righy. Response to Information Request Item No.T-O0.dacx al °