Calculation of Design Discharges using Rationai Method
ARE + Year 2 Year 10 Year 20 Year §0 Year
fl 50% 50% 50% 50% 50%
Cro 08 08 08 0.8 os
Fy 08 0.85 1 1.05 1.15
cy 0.84 0.68 08 0.84 0.92
te (min) 6 min 6 min 6 min 8 min 6 min
| (mnvhr) 116 148 204 232 269
A (Ha) 0.81 0.84 0.81 0.81 0.81
Q (ms 0.17 0.23 0.37 0.44 0.56
Capacity of 300 diamater pipe at 10% grade = 0.35 m3/s (Refer Chart attached) > Q6 (0.31m3/s) Therefore OK
Capacity at Culvert entrance based on an allowable headwater depth of approximately 0.9m = 0.17m3/sec (Refer culvert chart attached)
Therefore Remaining flow In 100 year storm event Is 0.64 - 0.17 = 0.47m3/s
Calculation of Overland Flow Capacity down driveway using Mannings Equation
{ ne
Crossfail
0.012
2%
$=
1.0%
arnatBulldl