"GENERAL NOTES

1. ALL WORK IS TO COMPLY WITH THE QUEENSLAND PLUMBING & DRAINAGE ACT
2002 AND LOCAL: AUTHORITY REQUIREMENTS,

2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY. USE DIMENSIONED BUILDING
CONSTRUCTION PLANS FOR ANY SET OUT REQUIREMENTS.

3. OBTAIN APPROVALS FROM ALL AUTHORITIES HAVING JURISDICTION AND PAY
ALL FEES DUE.

4, THE CONTRACTOR IS TO VISIT THE SITE TO BE FULLY AWARE OF EXISTING
SERVICES AND SITE CONDITIONS PRIOR TO COMMENCEMENT OF WORK. ANY
CLAIM FOR VARIATION ON THE BASIS OF LACK OF KNOWLEDGE WILL NOT BE
ACCEPTED.

5. ENSURE INVERT LEVELS AND MINIMUM COVER IS ACHIEVABLE PRIOR TO
COMMENCEMENT OF WORK ON SITE.

6. ALL PLUMBING AND DRAINAGE SERVICES THAT PENETRATE FIRE RATED WALLS

AND FLOORS MUST BE INSTALLED TO COMPLY WITH THE REQUIRED FIRE
RESISTANCE LEVEL.

SANITARY NOTES

1, ALL SANITARY AND TRADE WASTE PIPEWORK SHALL BE 100MM% AND BE
INSTALLED AT 1:60 MINIMUM GRADE (UNO).

2. PROVIDE INSPECTION OPENINGS ON SANITARY DRAINAGE IN COMPLIANCE WITH
AS/NZS 3500.2

3. AN OVERFLOW RELIEF GULLY SHALL BE INSTALLED ON EACH DRAIN
CONNECTION TO SEWER AND EACH DRAIN ON AN UNSEWERED PROPERTY.

4. AN INSPECTION SHAFT TO BE INSTALLED AT OR NEAR THE POINT OF
CONNECTION TO THE SEWER (UNO).

STORMWATER NOTES

1, ALL STORMWATER DRAINAGE SHALL BE 100MM@ AND BE INSTALLED AT 1:100
MINIMUM GRADE (UNO).

2. DOWNPIPES TO HAVE MINIMUM CROSS SECTIONAL AREA EQUAL TO 100MMé
(UNO).

3. ROOF GUTTERS AND DOWNPIPES TO FULLY COMPLY WITH THE REQUIREMENTS
OF AS/NZS3500.3.

MATERIALS

WATER SERVICES — TO AS/NZS 3500

SANITARY DRAINAGE — PVC CLASS DW.

SANITARY PLUMBING — PVC CLASS DWV

- & ND

DOWNPIPES - PVC CLASS DWV(UNO)
5. STORMWATER UP TO 300MM@ — PVC CLASS SW HEAVY (UNO)

6. STORMWATER OVER 300MM@ — CONCRETE (RUBBER RING JOINT) CL3/FRC
(SUPERTITE) CLASS 2

7. SUBSOIL DRAINAGE — 100MM@ PERFORATED PVC IN FILTER SOCK (UNO)
8. FIRE SERVICES ABOVE GROUND - ONE STEEL "FIRE PLUS” MEDIUM

9. FIRE SERVICES BELOW GROUND — PVC—M (BLUE RHINO)

10, TRADE WASTE INGROUND — HDPE OR VITRIFIED CLAY

11. TRADE WASTE ABOVE GROUND — HDPE OR POLYPROPYLENE

 

WATER SERVICE NOTES

1. COLD WATER PIPEWORK TO BE A MINIMUM OF 15MM¢@ TO INDIVIDUAL

ABBREVIATIONS

DOWNPIPE

EXPANSION JOINT

FINISHED FLOOR LEVEL

FINISHED SURFACE LEVEL
INSPECTION OPENING TO SURFACE
INVERT LEVEL

STORMWATER

SURFACE LEVEL

UNLESS -NOFEB—OTHERWISE

 

OUTLETS/FIXTURES AND 20MM@ OR GREATER TO MORE THAN ONE DP
OUTLETS/FIXTURES (UNO). EJ
2. 15MM@ COLD WATER PIPEWORK TO BE A MAXIMUM LENGTH OF 3METRES. a
3. WATER SUPPLY PIPE SIZES INDICATED ON THESE DRAWINGS ARE EQUIVALENT 10S
TO TYPE "B” COPPER TUBE. IF USING AN ALTERNATIVE MATERIAL THE IL
INTERNAL DIAMETER OF THE PIPE SHALL BE EQUAL TO OR GREATER THAN sw
THAT INDICATED ON THESE DRAWINGS. SL
4, HEATED WATER PIPEWORK SHALL BE 20MM® FROM THE HEATER TO SHOWER UNO

BRANCH THEN 15MM@ TO ALL OTHER OUTLETS/FIXTURES.

5. WATER HEATERS IN CEILING SPACE SHALL HAVE THE ISOLATING VALVES BELOW
CEILING.

6. WATER PIPEWORK TO BE INSTALLED IN WALL FRAMING AND ABOVE CEILING
(UNO).

7. ALL HEATED WATER OUTLETS USED PRIMARILY FOR PERSONAL HYGIENE
PURPOSES ARE TO BE TEMPERATURE CONTROLLED TO A MAXIMUM OF 50°C

LEGE ND ~ Tewantin

Development Counter

 
 

~ 8 JUN 2010

 

 

 

GENERALLY AND 45°C AT DISABLED ACCESS AREAS.

   

 

SANITARY
8. HEATED WATER TO DISABLED ACCESS AREAS TO BE TEMPERATURE CONTROLLED SUBSOIL —_— 7
BY A THERMOSTATIC MIXING VALVE. STORMWATER _-_ oOo oe ee
EXIST SANITARY PLUMBING —— sP
EXIST SEWER s
EXIST STORMWATER ———— sw
20 & 22 TRISTANIA DRIVE
;
}
i
A [eoosa CLIENT ‘8
Issue [DATE | REVISION STATUS ESIGNED}
fame (20 bradford
gt plumbing consultants
bz BG oh ae
ae eat Zo + PIF - (07) 5448 3875 piy ie
ian bradford * focovs"
consultants PEREGIAN BEACH 04573
pty td + €- IbradfordQoptusnet.com.au
BSA LICENCE NUMBER:- 1121367
LICENCE CLASS:- HYDRAULIC SERVICES DESIGN
(including on site wastewater management)

 

 

4 LOCALITY MAP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

PROJECT
STORMWATER DISPOSAL

PROPOSED 4 UNIT DEVELOPMENT
20 & 22 TRISTANIA DRIVE

MARCUS BEACH

TITLE

HYDRAULIC SERVICES
LEGEND, NOTES, LOCALITY MAP,
ABBREVIATIONS

CUENT

ALTUM CONSTRUCTIONS|

 

 

DWG NO REV

10031 - 4 A

 

 

 

AZ SCALE NTS U.N.O.
SHEET 1 OF 2

 

 

 

 

Used in these records

About this file

File size
9.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

10_0812 - Multiple Housing Type 2 - Duplex [As Published].pdf · 9.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.