Council archive · source document
002 ECM_22595441_v2_Approved Plans - NDN - MCU22 0087 & OPW22 0140 · MCU22/0087.01
Plans and drawings: the text below has words only, no drawings.
Very large file (27.6 MB): may take a few minutes to open.
Original PDF page 25, section 1. The text section number identifies this passage in the reader.
Notes: FSL
(X)
Notes: - All timber to be CCA pressure treated to
- Place the rootball on a firmed base to achieve required FSL. AS1604, Hazard 5, rough sawn pine.
- Thoroughly water the root ball immediately after planting. Notes: Timber edge
- All timber edges to be arissed to comply
- Number of stakes will vary with pot size. Refer plant schedule. - Place the rootball on a firm base. with council standards.
- Cultivate sides of excavated hole 50mm. - Thoroughly water the root ball immediately after planting. - All timber ends to have one coat of Stakes
- Cultivate sides of excavated hole 50mm deep. Cuprinol or equal prior to installation.
- Do not disturb kerb, road pavement or road side drainage works. - Stakes to be 400mm into ground at max.
- Tease out roots on side of rootball when planting. 1200mm centres, or as required to obtain Existing/compacted
- Ensure top of rootball is not buried; expose and set flush with finished level. smooth curves. Top of stake to finish /subgrade/subase
20mm below top of timber edge. Where
timber edges meet at corners provide
Hardwood Stake: double stakes.
25x25x90mm Place 600mm 90mm∅ capped slotted pipe - All fixings to be hot dipped galv.
into the ground. Do not 75mm below top of planter - Leading edge is to be free of burrs and
place through rootball. connected to drainage system splinters.
Secure with ties by looping per Hydraulic Engineer
in a figure eight pattern. River stone to
Hardwood stake: Place 600mm top of pipe TIMBER EDGE STAKES (X) = Height above
Mulch: Pull away from into the ground. Do not place Mulch
38 50 finished surface level FIXINGS
base of plant. through rootball. Secure with - refer to plans for organic or
ties by looping in a figure eight inorganic locations 50mm Bugle Headed
FLUSH
Form an earthen basin pattern. Batten Screws.
100
around base of plant. 20mm 75mm Bugle Headed
Raise plant 50mm above Podium soil Batten Screws.
finished surface level. 100mm
varies
- refer to Specification
Mulch: Pull away from base 100mm Bugle Headed
150mm Batten screws.
Topsoil blend of plant. 100x38mm
Geotextile fabric
Fertiliser: Do not allow Form an earthen basin
contact with roots. around base of plant. 30mm Atlantis drainage cell 50x50mm
or similar approved
Water retention additive
Topping slab - If required. 4 EDGE TYPE 1
Topsoil blend Depth varies to achieve falls CD-900 1:5@A1, 1:10@A3
min 300
Timber garden edge
to drain.
1 140-300mm PLANTING Water retention additive
Waterproofing and protection
CD-900 1:10@A1, 1:20@A3 1 - to Architect's Specification.
Fertiliser: Do not allow
fertiliser to come in 1 Podium / basement slab
contact with roots. - refer Engineer's detail.
width (w)
10 - 20mm Drainage gravel
2xw 3 PODIUM PLANTER
CD-900 1:10@A1, 1:20@A3
2 45-200ltr PLANTING
CD-900 1:10@A1, 1:20@A3
FSL Notes:
Mulch Notes: 1. Construction joints: Place at minimum 5m centres.
- to 100mm depth - Thoroughly water the root ball immediately after 2. Tool joints: Make tool joint at equal distances from
planting. both ends. Make joint at points of change in curvature/
Turf as specified direction. Joints to be at right angles to direction of
Soil blend or site topsoil Marker stake: edge.
- to 300mm depth Topsoil 12x12x75mm Mulch - refer to Specification.
- to 100mm depth Tree guard
Continuous extruded mowing
Form an earthen basin
Cultivate subgrade strip. Profile as indicated
around the base of the
Cultivated subgrade - to 150mm depth below.
plant.
- to 150mm depth
Existing subgrade Mulch: Pull away from Turf - refer to Specification.
base of plant. 250 Topsoil - refer to
Specification
25
Cultivated subgrade - refer to
Specification.
Fertiliser: Do not allow Compacted subgrade to be
contact with roots.
6 TURF PROFILE Nom. 200mm thickness.
5 GARDEN BED PROFILE
CD-900 1:10@A1, 1:20@A3 Turf profile scale 1:5
CD-900 1:5@A1, 1:10@A3
Topsoil blend
Existing subgrade
Water retention
additive
7 TUBESTOCK PLANTING 8 EDGE TYPE 2
CD-900 1:10@A1, 1:20@A3 CD-900 1:5@A1, 1:10@A3
Concrete garden edge
NOOSA COUNCIL
APPROVED PLAN
MCU22/0087 & OPW22/0140
B
25 SEPTEMBER 2023
Revision Date Amendment Drawn Checked
APPROVAL ONLY
CONSTRUCTION DETAILS NOT FOR CONSTRUCTION
A
B
24.11.2022
28.02.2023
For Approval
For Approval
XL
XL
CS
CS
CD-900 scale as noted
37 BOTTLEBRUSH AVENUE , NOOSA HEADS
JOB NUMBER: 22432 CLIENT NAME: BOTTLEBRUSH PROPERTY TRUST
Document Set ID: 22595441
Version: 2, Version Date: 25/09/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
002 ECM_22595441_v2_Approved Plans - NDN - MCU22 0087 & OPW22 0140.pdfRelated documentApplication case desk ↗
About this file
- File size
- 27.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.