Original source · versioned page text
20.001-018_44 The Peninsula_Form 15
Attached to the e-mail Combined Application Landing & Jetty MCU21/0084 & OPW21/0130 -DA Form 1- Owners Consent - Plans.
Department of Housing and Public Works
Form 15—Compliance certificate
for building design or
Version 4 – July 2017
specification
NOTE: This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the
Building Regulation 2006.
RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether building work
complies with the BCA or a provision of the Queensland Development Code (QDC). A building certifier (Class B)
can not give a certificate regarding QDC boundary clearance and site cover provisions.
1. Property description Street address (include no., street, suburb/locality and postcode)
This section need only be 44 The Peninsula
completed if details of street
address and property description Noosaville Postcode 4566
are applicable.
E.g. in the case of Lot and plan details (attach list if necessary)
(standard/generic) pool design/shell Lot 431 RP856193
manufacture and/or patio and
carport systems this section may In which local government area is the land situated?
not be applicable. Noosa Council
The description must identify all
land the subject of the application.
The lot and plan details (e.g.
SP/RP) are shown on title
documents or a rates notice.
If the plan is not registered by title,
provide previous lot and plan
details.
2. Description of Structural components associated with a new domestic ‘L’ jetty, including
component/s certified hardwood timber piles, timber framing; aluminium handrail & kayak step.
Clearly describe the extent of work
covered by this certificate, e.g. all Excludes:
structural aspects of the steel roof
beams.
Decking (by others)
Methods of construction including temporary bracing and propping
Existing structures on the site, including the existing revetment wall
3. Basis of certification AS1170 SAA Loading Code
Detail the basis for giving the
certificate and the extent to which AS1664 Aluminium Structures
tests, specifications, rules,
standards, codes of practice and other AS1720 Timber Structures
publications, were relied upon.
AS2159 Piling Code
AS4997 Guidelines for the Design of Maritime Structures
The Coastal Protection and Management Regulation 2017: relevant Parts and
Schedule 3
4. Reference documentation Long View Consulting Engineers Drawings 20.001-018 44 The
Clearly identify any relevant
documentation, e.g. numbered
Peninsula_Construction Issue C1 S-01 to S-05 inclusive
structural engineering plans.
LOCAL GOVERNMENT USE ONLY
Date received Reference Number/s
See the original
The page text is free to read. Viewing or downloading an original file needs an account.