PLANT SCHEDULE GENERAL PLANTING NOTES
TREES 1. PLANT QUALITY
LEGEND CODE BOTANICAL NAME
MINIMUM MIN HEIGHT QTY STKS/ CLPR CLEAN All plant stock is to be be to the scheduled nomenclature, well formed, hardened off nursery stock. Collect all empty plant containers daily during planting operations and remove from site.
POT SIZE AND SPREAD GUYS STEM Keep soil level and flush so that watering will not not push soil in around trunk of tree. Any
They are to be container grown in potting mixture with a healthy root system and not pot bound. All
EXTERNAL WORKS ACM hem
CUP ana
ACMENA hemilampra
CUPANIOPSIS anacardioides
45ltr
45ltr
2500x1200mm
2500x1200mm
2
1
50mm
50mm pots shall be free of weeds and plant stock is to be free from living insects, pests and disease. All watering berms are to be made of mulch only.
HAR pen HARPULLIA pendula 45ltr 2500x1200mm 3 50mm plants are to be fully sun or shade hardened-off to suit their on-site growing position for a minimum Do not vary the plant locations from those specified on the drawings unless otherwise
HARDSCAPE SOFTSCAPE SYZ aus SYZYGUM australe 25 ltr 1500x1000mm 1 0 period of 6 weeks. directed by the Superintendent. Should it be necessary to vary the locations and spacing for
TRI lus TRISTANIOPSIS laurina 'Luscious' 45ltr 1700x800mm 3 25mm
TURF - A-Grade FENCE & GATE TYPE 1 2. ADVANCED TREE NOTES. any reason, immediately apply for directions by the Superintendent.
F1 & GT1
T1 Buffalo refer to materials schedule SHRUBS All advanced trees 25L or greater are to be certified as either Natspec or AS2303 compliant. 4. PLANT ESTABLISHMENT
Sir Walter The Establishment Period commences at the date of Practical Completion of Works.
CODE DESCRIPTION SIZE HGT&SPRD QTY. STKS Contractor to sight and supply certification to superintendent prior to accepting trees from the
TURF - A-Grade GROUNDCOVERS/SHRUBS During the Establishment Period maintain best horticultural practices including (but not
T2 Couch CAL GBF CALLISTEMON 'Great Balls of Fire' 200mm 500x300mm 13 nursery. Contractor is to review all tree stock at unloading and prior to planting to ensure the
Wintergreen COR neg CORDYLINE negra 200mm 200x100mm 22 following: Trunk is not burried below flare in trunk at top of roots; There is no sign of root girding; limited to) the following items where required: watering, weeding, fertilising, pest and
P1 - CONCRETE SLAB HEDGES COR rub CORDYLINE rubra 200mm 200x100mm 3 Tree is self supporting; Tree is of good form and health; When bag is removed roots are not circling or disease control, mulching, pruning, rubbish removal and keeping the site neat and tidy.
P1 to match Architects GAR flo GARDENIA augusta 'Florida' 200mm 200x100mm 14 Rectify defects that become apparent in the works under normal use
specification IXO GF IXORA 'Gold Fire' 200mm 450x250mm 33 pot bound. Trees that fail these criteria should not be planted and are to be returned to nursery. Trees
LIR EG LIRIOPE 'Evergreen Giant' 200mm 300x300mm 63 are to be planted 20-30mm above finish level to allow for settling. Rip side of root ball prior to 5. PLANT REPLACEMENT
STEPPER ACCESS TREES
400 x 400mm pavers LOM til LOMANDRA confertifolia 'Tilga' 200mm 500x300mm 17 planting to loosen roots. Replace failed or damaged plants. This does not include vandalised or stolen plant material
& pebble surround SYZ cas SYZYGIUM 'Cascade' 300mm 1200x600mm 18 - these will be replaced prior to practical completion or at the superintendents direction.
SYZ pin SYZYGIUM 'Pinnacle' 300mm 1200x600mm 44 3. IMPLEMENTATION
EDGE TYPE 1 6. MULCH
EG1 - Refer to CD-200 SYZ res SYZYGIUM 'Resilience' 300mm 1200x600mm 10 Ensure all planting procedures result in healthy plant species within the prevailing soil, climatic and
WES nar WESTRINGIA naringa 200mm 450x250mm 30 management environment of this project. The following minimum is expected: All mulch is to be free of deleterious or extraneous matter such as soil, weeds, rocks, and
TRI jas TRACHELOSPERMUM jasminoides 140mm 150x300mm 58
- Excavate a hole for each plant twice the diameter of the rootball and 100mm deeper than the twigs. The finish level of the mulch is to be level with the finish level of all adjacent surfaces
root ball. Break up the base of the hole to a further depth of 100mm and loosen the sides of the hole. after settlement allowances of the topsoil and mulch. Ensure all mulch is placed clear of
MATERIALS & FINISHES SCHEDULE - Remove the plant from the container, tease out roots and place in final position, ensure it is plant stems to avoid rotting at ground level. Mulch is to be chipped forest mulch (a
combination of wood, leaves and bark) or approved equal.
CODE / ITEM REQUIREMENTS central and plumb. Ensure the root ball is level with the finished surface of the soil surrounding the
hole or bed.
- Ensure correct placement of fertiliser and/or water retention additive as per manufacture's
specification and requirements.
Timber Edge Type 1 100 x 38mm treated pine planting edges with 500 x 38 x 38mm treated pine pegs at - Backfill with topsoil as specified. Lightly tamp and water thoroughly to eliminate any air pockets.
(EG1) nominal 1200mm centres. Refer to detail -
Ensure that topsoil is not placed over the top of the rootball or where base of trunk flares. Refer to
Paving Type (P1) Adbri Masonry 'Euro Stone - ZURICH' Paver L: 400mm x D: 400mm x H: 40mm. Details on CD-X as reference. APPROVED PLANS
MCU19/0029 & OPW19/0064
Refer to details for installation method - Thoroughly water plants immediately after planting and at such times during the contract
period as required. All plant stock will require a minimum of 10ltrs of water at the time of planting.
1.8m high timber 1800mm high Treated Hardwood/Treated Pine timber overlapping paling fence.
fence and gate (F1 Natural treated pine finish. Posts are to be evenly spaced at a maximum of 2.4m set & RAL19/0006
and G1)
NOOSA COUNCIL
into a 30 MPA mass concrete footing 300mm dia x 600mm deep. Gate to match.
Riverstone Pebble Mary Riverstone Pebble 20-40mm dia laid 100mm thick on compacted sub-grade
(P1) for stepper surround 14 AUGUST 2019
-
1800mm high block
Timber Fence and Gate, rendered wall, specified
refer to Materials Schedule 1 SYZ aus
5 IXO GF 5 IXO GF 5 IXO GF by Architect
3 COR neg 6 SYZ pin 3 SYZ cas 3 SYZ pin 3 SYZ pin 3 SYZ pin 3 SYZ pin 3 SYZ pin
6 SYZ cas 3 CAL GBF
1 HAR pen 4 LIR EG 4 LIR EG 4 LIR EG
2 GAR flo
SIGNAGE
EG-1 EG-1 EG-1 EG-1 T2
T2
P2
F1 & GT1 5 LIR EG
P2 P2 P2 EG-1 T1 10 LOM til
EG-1 1 TRI lus 9 LIR EG Timber Boundary Fence
8 TRA tri 3 IXO GF 3 IXO GF to be specified by
//
7 LOM til 2 SYZ cas
EG-1 Architect
3 COR neg 5 CAL GBF
F1 & GT1
//
8 TRA tri EG-1 1 ACM hem
3 SYZ cas
T1 3 WES nar
Bin Enclosure wall to be
STREET
1 TRI lus
5 LIR EG 1800mm high. To be EG-1
P2 detailed by Architect.
5 TRA tri
EG-1
5 LIR EG
6 SYZ res
EG-1 5 CAL GBF
EG-1 SIGNAGE T2
3 COR rub 3 LIR EG
P1
1 HAR pen
5 LIR EG 4 SYZ cas
6 GAR flo Internal pathways EG-1 1 ACM hem
to be specified by 1 TRI lus
GARNET
Architect 4 WES nar
6 GAR flo 8 LIR EG
P1 EG-1
1 CUP ana
7 LIR EG EG-1
P1
3 COR neg 3 COR neg T2
P2 3 COR neg 3 IXO gf 3 IXO gf 3 IXO gf
3 COR neg
T1 4 TRA tri 4 TRA tri 4 TRA tri
EG-1
3 TRA tri 3 TRA tri 1 COR neg
3 TRA tri New Concrete
3 IXO gf 4 TRI tra
Footpath, 125mm
4 TRA tri
EG-1
thick
4 SYZ res
1 HAR pen
EG-1 4 LIR EG
4 TRA tri
F1 & GT1 5 WES nar 9 SYZ pin 5 WES nar 6 SYZ pin 7 WES nar
SIGNAGE
8 TRA tri 8 SYZ pin
3 COR neg
6 WES nar Driveway crossover to be
detailed by engineers
Revision Date Amendment Drawn Checked
APPROVAL ONLY
8 GARNET STREET, COOROY NOT FOR CONSTRUCTION
A
B
C
2019.02.05
2019.02.12
2019.05.08
For Approval
For Approval
For Approval
AL
AL
AL
CS
CS
CS
CD-001 scale: 1:100A1; 1:200@A3
DRENTH UNIT DEVELOPMENT NORTH
JOB NUMBER: 19017 CLIENT NAME: TRAVIS DRENTH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Approved Plans - MCU19-0029.01, OPW19-0064.01 & RAL19-0006.01.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.