Reference Document - Bushfire Risk Assessment & Bushfire Risk Management Plan

of 41

Page text shows just the words. Original shows the document exactly as it was published.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
                         Ecological Natural Area Management


6.3    Tabulation of the Potential Bushfire Intensity Class
Using the inputs derived above, the Potential Bushfire Intensity Classes for the patches of
vegetation are tabulated below.

Table 5: Table of Potential Bushfire Intensity Class derived from Potential Fire line Intensity
             Potential Bushfire Intensity Class                               Potential Fire-line Intensity
                          Very high                                                    >40,000 kW/m
                            High                                                 20,000 to 40,000 kW/m
                          Medium                                                 4,000 to 20,000 kW/m
                            Low                                                  Less than 4000 kW/m
(Source: Leonard et al, 2014, page 20)

Table 6: Tabulation of the potential bushfire intensity classes for each of the patches
    Patch        Vegetation class         Fuel load       Slope      FDDI      Fireline Intensity     Potential Bushfire
                                                                                                       Intensity Class
   Patch 1    Moist to dry eucalypt       24.1 t/ha       2.8 0        50         21771 kW/m                  High
              open forests
   Patch 2    Low grass or tree cover         5 t/ha      3.1 0        50              963 kW/m               Low
              in rural areas
   Patch 3    Low grass or tree cover         5 t/ha      3.7 1        51          1020 kW/m                  Low
              in rural areas
   Patch 4    Low grass or tree cover         5 t/ha      4.4 2        52          1092 kW/m                  Low
              in rural areas
   Patch 5    Low grass or tree cover         5 t/ha      4.9 3        53          1153 kW/m                  Low
              in rural areas
   Patch 6    Low grass or tree cover         5 t/ha      5.8 4        54          1247 kW/m                  Low
              in rural areas
   Patch 7    Low grass or tree cover         5 t/ha      6.3 5        55          1314 kW/m                  Low
              in rural areas
   Patch 8    Low grass or tree cover         5 t/ha      3.1 6        56          1073 kW/m                  Low
              in rural areas
   Patch 9    Low grass or tree cover         5 t/ha      3.0 0        50              954 kW/m               Low
              in rural areas




Bushfire Risk Assessment and Management Plan for a house at 64 Pheasant Lane, Doonan                          September 2020

                                                            18
Log in to download the original file

Reference Document - Bushfire Risk Assessment & Bushfire Risk Management Plan.pdf · 6.1 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.