Original source · versioned page text
Hydraulic Services Plan
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn400mm | 50_ | 40_ | 30_ |_20_ | 40_ omm HYDRAULIC SERVICES TOWNHOUSE DEVELOPMENT 101 & 105 EUMUNDI NOOSA ROAD NOOSAVILLE QLD 4566 Lot 1 on RP230931 & Lot 1 on RP849431 Noosa Shire Council Materials 1. WATER SUPPLY PIPE SIZES SPECIFIED ON THESE DRAWINGS ARE BASED ON CALCULATIONS FOR PIPES HAVING EQUIVALENT DIMENSIONAL AND FLOW CHARACTERISTICS TO THAT OF TYPE B COPPER TUBE. WHERE ALTERNATIVE MATERIALS ARE USED AN EQUIVALENT PIPE SIZE APPROPRIATE TO THE MATERIAL BEING USED SHALL BE SELECTED. 2. COLD WATER COPPER TYPE 'B’* FIRE (IN-GROUND) uPVC PRESSURE PIPE CLASS 'M' OR 'O' FIRE (ABOVE-GROUND) GALVANISED STEEL * PIPE AND FITTING MATERIALS MAY BE SUBSTITUTED PROVIDED ALTERNATIVE MATERIALS ARE AUTHORIZED FOR USE IN ACCORDANCE WITH THE PLUMBING CODE OF AUSTRALIA (PCA). FOR WATER SERVICES REFER ALSO: AS/NZS3500.1 SECTION 2 AND APPENDIX B - ACCEPTABLE PIPE AND FITTINGS SYMBOLS ™ ISOLATION VALVE ISOLATION VALVE IN PATH BOX a WATER METER o DUAL-CV SINGLE TESTABLE CHECK VALVE ASSEMBLY INCLUDING ISOLATION VALVES AND LINE STRAINER END CAP DROPPER fe} ain IN-GROUND SPRING HYDRANT LINETYPES - SERVICES BY OTHER'S — CS — _ CIVIL- SEWER MAIN NEW UTILITY WATER BRANCH LINETYPES - PROPOSED -——-—— COLDWATER —— — — _ FIRE SERVICE LINETYPES - EXISTING w COLD WATER c COMMUNICATIONS e ELECTRICAL s SEWER sw STORMWATER ABBREVIATIONS DUAL-CV Dual Check Valve DPH Dual Pillar Hydrant e Existing eFH Existing Fire Hydrant MH Manhole SCV Single Check Valve SEW Sewer SH Spring Hydrant SL Surface Level SMH Sewer Manhole SWMH : Stormwater Manhole WM Water Meter WMP Water Sub-Meter in Path Box Building Information BUILDING CLASSIFICATION 1a&2 STOREYS CONTAINED 2 BUILDING FLOOR AREA <500m? SOIL CLASSIFICATION TBC NOTE: FIRE HYDRANTS LOCATED IN ACCORDANCE WITH SPP ( EXISTING SERVICES DRAWN FROM HISTORICAL RECORDS. CONTRACTOR TO CONFIRM THE LOCATION, DIAMETER AND INVERT LEVELS OF ALL EXISTING SERVICES ON-SITE PRIOR TO COMMENCEMENT OF ANY WORKS AND ALLOW ALL ASSOCIATED COSTS ——— NOTE: DRAWING REQUIRED TO BE PRINTED IN COLOUR HT] s 1508 s Ss rc e150 @ RETICULATION SEWER MAIN 1500 NEW 150@ 'PREMISES MAIN' ASSEMBLY COMPLETE WITH 150@ SINGLE TESTABLE CHECK VALVE (50kPa SPRING) & 65@ METERED BY-PASS IN ACCORDANCE WITH BOUNDARY CONNECTION DETAIL SEQ-WAT-1108-6. ja | Lo. APT 19 FFL 18.500 APT 15 APT 16 1508 400 THOS | TH 04 FFL 18.500 TH 02 | — —I c c —e EUMUNDI NOOSA ROAD SITE PLAN — e300. @ TRUNK WATER MAIN (ASSET ID: 5229113) _ Ww Ww Ww WwW Ww WATER SERVICES SCALE: 1:300 AT SHEET A1 50 100mm _10 | 21.07.21 | sp JissueD FOR AMENDED SITE PLAN T 02 | wo 27.01.21 | Sb. [ISSUED FOR DA HYDRANT RFI [ot T svo | srace DESCRIPTION [Rew wo| AUTH. ARCHITECT \ BUILDING DESIGNER BLACKBURNE JACKSON DESIGN & ARCHITECTURE 37 AERODROME ROAD MAROOCHYDORE QLD 4558 5443 3200 CLIENT ALTUM CONSTRUCTIONS HYDRAULIC CONSULTANT MRP HYDRAULIC & FIRE SERVICES CONSULTANTS PTY LTD uo BRISBANE m SUNSHINE COAST A: — Suite 2/22 Denna Street, Maroochydore, QLD. PO Box 646, Cotton Tree, QLD, 4558. P: (07) 5443 1000 E: — [email protected] P: — mrp.com.au BSA: 1137134 ABN: 23 126 270 326 QBCC: 1137134 PROJECT DESCRIPTION & ADDRESS TOWNHOUSE DEVELOPMENT 401 & 105 EUMUNDI NOOSA ROAD NOOSAVILLE QLD 4566 Lot 1 on RP230931 & Lot 1 on RP849431 SIMON LYNCH " JASON VAN DYK | 21.07.21 HYDRAULIC SERVICE SHEET DESCRIPTION SITE PLAN WATER SERVICES PROJECT NUMBER SCALE ‘SHEET SIZE ISSUED FOR APPROVALS 20-0877 Noted Al SHEET NUMBER H:\Synergy\Projects\20\20-0877 Townhouse Development - Lot 101 & 105 Eumundi Road, Noosaville\X_MRP\Doc_ Current Drawing Files - saved by : Jason - plot by : Jason Van Dyk H-201 “02 100mm
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.