APPROVED Amended Plans · OPW12/0093

of 2

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
 

 

GENERAL NOTES

1,

ALL WORK IS TO COMPLY WITH THE QUEENSLAND PLUMBING & DRAINAGE ACT
2002 AND LOCAL AUTHORITY REQUIREMENTS.

STORMWATER NOTES

1. ALL STORMWATER DRAINAGE SHALL BE 100MM@ AND BE INSTALLED AT 1:100
MINIMUM GRADE (UNO).

MATERIALS

WATER SERVICES — TO AS/NZS 3500

SANITARY DRAINAGE — PVC CLASS DWV

ABBREVIATIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.
2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY. USE DIMENSIONED BUILDING 2. DOWNPIPES TO HAVE MINIMUM CROSS SECTIONAL AREA EQUAL TO 100MMé
CONSTRUCTION PLANS FOR ANY SET OUT REQUIREMENTS. (UNO). 3. SANITARY PLUMBING — PVC CLASS DWV
3. OBTAIN APPROVALS FROM ALL AUTHORITIES HAVING JURISDICTION AND PAY 3. ROOF GUTTERS AND DOWNPIPES TO FULLY COMPLY WITH THE REQUIREMENTS 4. DOWNPIPES — PVC CLASS DWV(UNO)
ALL FEES DUE. OF AS/NZS3500.3.
4. THE CONTRACTOR IS TO VISIT THE SITE TO BE FULLY AWARE OF EXISTING Bi STORMWATER 'UE?TO [SQOMME! -~ AVE: GEASSESW HEAVY (UNS)
SERVICES AND SITE CONDITIONS PRIOR TO COMMENCEMENT OF WORK. ANY
CLAIM FOR VARIATION ON THE BASIS OF LACK OF KNOWLEDGE WILL NOT BE
ACCEPTED.
5. ENSURE INVERT LEVELS AND MINIMUM COVER IS ACHIEVABLE PRIOR TO
COMMENCEMENT OF WORK ON SITE.
6. ALL PLUMBING AND DRAINAGE SERVICES THAT PENETRATE FIRE RATED WALLS
AND FLOORS MUST BE INSTALLED TO COMPLY WITH THE REQUIRED FIRE
RESISTANCE LEVEL.
~~;
a —
s
o
a
( EXISTING WATER MAIN 4
| EXISTING SEWER —|
bs U B
~ b
&
° z
5
1
/ J
Ww Ww [ Ww Ww Ww Ww Ww
M
<3 Ss s s s s s
EXISTING OPTUS CABLE
sot s s s s s s
2

SITE PLAN

(REFER 1:100 PLAN FOR DETAILS)
SITE 1:200

 

DP DOWNPIPE

e EXISTING

HV HYDRANT VALVE

Ic INSPECTION CHAMBER

10 INSPECTION OPENING

los INSPECTION OPENING TO SURFACE
MH MANHOLE

SW STORMWATER

UNO UNLESS NOTED OTHERWISE
LEGEND

STORMWATER se neste
EXIST SEWER —_———s

EXIST STORMWATER — sw

EXIST WATER —_—_w

EXIST OPTUS — -- ——_- -- ——_

SUNSHINE COAST REGIONAL COUNCIL
APPROVED

 

 

 

 

 

 

opw 120093 21 MAY 2012
B 10/06/12 | EXISTING SERVICES ADDED SW CLIENT 18
DISCHARGE REVISED
ISSUE | DATE REVISION. STATUS. DESIGNED}

 

 

 

 

 

  
  

Plumbing consultants
pty Ita

+ PIF - (07) 5448 3875

0412654598

PO BOX 334

PEREGIAN BEACH 04573

+ [email protected]

+_W- wenwsibplumbingconsultants.com.au

BSA LICENCE NUMBER:- 1121367
LICE! - HYDRAULIC SERVICES DESIGN
(including on site wastewater management)

PROJECT

STORMWATER DRAINAGE ALTERATIONS
TELSTRA TELEPHONE EXCHANGE

30 WYANDRA STREET, NOOSA HEADS

TITLE

    

ian bradford
plumbing consuitan
ay ted

 

   
 

 

 

 

 

 

 

HYDRAULIC SERVICES
COVER SHEET
EXISTING SERVICES HAVE BEEN cuENT ONS NO a

COPIED FROM 'DIAL BEFORE YOU | McTAGGART PLUMBING
DIG’ INFORMATION SERVICE AND PTY LTD
ARE NOT CONFIRMED.

A2 SCALE AS NOTED SHEET 1 OF 2

12027-1 | B

 

 

 

 

 

 
Full text of the other 1 page

Page 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STORMWATER CALCULATIONS

ROOF AREA = 340m?

RAINFALL INTENSITY (1 IN 20 YR) = 251mm/hr.
ESTIMATED FLOW = 24 LITRES/SECOND

 

 

SUNSHINE COAST REGIONAL COUNCIL
APPROVED

EXISTING 100mm? DOWNPIPES
CONNECT TO NEW 1500
STORMWATER DRAINAGE (TYPICAL

2:1 MAY 2012

 

 

 

  
 
  
 
 
   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW DRAINAGE THROUGH WALL
AND DROPS ON OUTSIDE WALL

600? GRATED GULLY PIT

600? GRATED GULLY PIT

3 x 125mm x 75mm STEEL
CHANNELS TO KERB. INSTALL
UNDER EXISTING PATH — ALL TO
SUNSHINE COAST REGIONAL

3.x 125mm x 75mm OUTLETS

 

 

 

 

& — Jovosr2 EXISTING SERVICES ADDED SW [CLIENT 18
DISCHARGE REVISED

A [zo0sne (CLIENT 8

issve[oaTe [REVISION STATUS [DESIGNED|

 

 

 

 

 

ian bradford

Plumbing consultants
pty Ita

 

+ PIF - (07) 5448 3875

> + M-0412654598

ian bradford): posox 334

plumbing consultants | PEREGIAN BEACH @4573

pty itd | * E-ianGibpc.com.au
+ _W- www.ibplumbingconsultants.com.au

 

 

 

 

BSA LICENCE NUMBER:- 1121367
LICENCE CLASS:- HYDRAULIC SERVICES DESIGN
(including on site wastewater management)

 

 

 

PROJECT

STORMWATER DRAINAGE ALTERATIONS
TELSTRA TELEPHONE EXCHANGE
30 WYANDRA STREET, NOOSA HEADS

 

(ene) (e0P)
5 Ce LZ
=, Zi = r
| ‘SW DRAINAGE THROUGH WALL TO UNDERCROFT |
\ E 7
\ : / .
\ 8 ( FOR EACH DP)
\ | | =
Xo _ XO la
5 oN | |
2
SW DRAINAGE SUSPENDED BELOW % )
FLOOR IN UNDERCROFT | OPW 120093
ry TO RUN INGROUND
L
4 qq
| {| UL
KO 2
G
| #
7} b
ee
750 g
j s
SW DRAINAGE CLIPPED ON z
OUTSIDE OF WALL Ne
Ss
SW DRAINAGE ABOVE DOORS
DROPPER TO RUN BELOW ry
VENTILATION. GRILL bat
SW DRAINAGE DROPS TO RUN N“
INGROUND Th, COUNCIL APPROVAL
Ss
FROM GULLY PIT
=
w
.%
z ae
ee
—w Ww Ww 7 Ww Ww ¥ Ww Ww WwW Ww w W Ww Ww Ww
a we ©) eSWMH
° eKERB
GULLY PIT %
s s s s s s s s s

PART SITE PLAN

SCALE 1:100

 

©) eSEWER MH

% note:
EXISTING SERVICES HAVE BEEN

COPIED FROM 'DIAL BEFORE YOU
DIG’ INFORMATION SERVICE AND
ARE NOT CONFIRMED.

TITLE
HYDRAULIC SERVICES
PART SITE PLAN

 

CLIENT DWG NO Fey
McTAGGART PLUMBING 12027-2 | B
PTY LTD

 

 

 

 

A2 SCALE 1:100 U.N.O. SHEET 2 OF 2

 

 

Used in these records

About this file

File size
1.1 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

APPROVED Amended Plans.pdf · 1.1 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.