IRequil’ed Inspections & Buildina Conditions (AttachmentA)
I:! Building Applicath>n No~00716091 .
Stage I InsEections \.,
Inspection Agenc1’ I Contact fol’ Inspectiolls ’.
Footing Stage Footing GMA Celtification Group Phone 07 55 781622
-
Site Inspectioll GMA Certification Group Phone 07 55 781622
-
Slab Stage Slab GMA Celtificatioll Group Phone 07 55 7816Z2
-
!Frame Stage Frame GMA Certification Group Phone 07 55 781622
-
final Stage Final GMA Certification Group Phone 07 55781622
-
I Certifier’s Standard Conditions
1 Notwithstanding anything stated in or omitted fi’om the documentation submitted by the applicant or stated in or omitted from
these conditions, all work is to comply with the
Building Act 1975,Building Regulation 2006, and the Plalming Scheme for Noosa
Shire Council.
2 In issuing this pennit GMA Certification
Gt.oup Ply Ltd does Dot certify that the design is cOITeet and does not assume 811y
responsibility for the correctness of the design.
3 Compliance with the Building Act 1975 flud the relevant Planning Scheme is the responsibility of the applcant.
4 Building work approved on this building application has to be
(a)commenced within [12 ]months of approval
(b)finalised within [2 J years ofapproval.
5 Further Development PClllIits Required.
*
Development Approval Plumbing & Drainage Work
6 To satist), the Building Certifier that the
Building work has been constructed to an acceptable standard, the foJ1owing
documentation will be required: (when relevant)
i) Certificate/s for footing and/or slab inspectionls of Class In building work where a
competent person carries out such
inspections as nominated in the building application submitted to and approved by tIle Building Cet1ifier.
ii) TlllSS Manufacturer’s Certificate, quoting the relevant wind classification.
iii) Engineer’s celtificatlon for structural work 1I0t in accordance with Boilding Code of
Australia, Volume 2 or manut cturer’s
specification.
iv) Licensed Applicator’s Certificate for Tennite Management in accordance with AS.3660.1 2000 -
(Clause 3.1,3. BCA)
v) Glass suppliers certification of window glass to AS 1288 for wind velocity and AS 2208
(Fat1 3.6 BeA),
vi) Glass suppliers certification of shower screens to AS 2208,
vii) A certificate from a licensed applicator wel IlI’eas is required, must comply with;
* AS
3740.1994
>)
Part 3.8.1- BCA.
viii) Certificate 110m a Licensed Electrician for the installation of Smoke Alanns in accordance witb AS 3786 and BCA
Prut 3.7.2
h:) Certificate from a Licensed Electrician for the installation of Energy Efficient
Lighting in accordance with Queensland
Development Code -
Part 29.
x) Certificate for the installation of the Insulation as required by the Energy Efficiency
Assessment, stating the Product uame and
R-Value.
xi) Surveyors Setout celtificate.
xii) Manufacturers certificate for Balustrades.
7 Waterproofing to wet areas (bathrooms,laundries and We’s) to comply with the requirelllents ofthe BeA3.S.1 and
AS3740.
8 Smoke a18lUls to be provided in accordance with BCA 3.7.2 and AS 3786. ,
’--
9 Surface Water, resulting from a stann having an
average reccurrence interval of 100 years must not enter the building. The Local
Government may hold records which provide infonnation in relation to Flood
levels, which may detel1nine the minimum required
floor level. (It is the applicants Iesponsibility to obtain
any necessary data)
10 Retaining Walls (IfApplicable) Retaining walls over I metre high need building approval and an
-
Engineru’s CrutHicate for the
design.
11 Toilet doors are to be provid with lift-off hinges where pailS are located within 1.2m of the door
swing arc.
12 The development is to strict y
comply with the ’conditiolls of approval’ issued by Noosa Council & which al"C attached to & fOlln
part of its MCV Approval (File 110.2004/5744 dated IS December 2005), OW
Approval (file tlo.20061 015 dated 14 December
2006) & ROL Approval (file no.21645 dated 14 June 2002).
13 Alllnrelnal Laundries not light~ by a window or skylight 0% of floor
(J Ilrca with 5% openeble) are to be
attiticaiJIy lit &
mechanically ventilated.
14 Notwjthstanding any of the illf011llation shown on the GMA endorsed & approved plans articulatioll
joints are to be installed in
accordance with soHtesl & tbe structural design
engineclJs requircII)ents.
15 Notwithstanding any of the illfonuation shown on the OMA endorsed & approved plans all wall substrate material & flnsh
gs in
’wet-areas’ are to strictly comply with the requirements of AS3740.
16 The requirelllents of the BCA 3.7.1.1 0 requircs roof
lights not to be located closer thun 1 SOOl1lm in adjoining dwellings.
Installation details & unabridged fire tests/product approvals
relating to the proposed glass block windows & !lt1culatioll joint
treatment to be used in the walls fITe
separating dwe)ljngs need to be submitted for assessment. Cover strips in eave Hnings are to
be nOEl-combustible where the dwelling walls are located less then 1.8m ITom
one another. BCA 3.7.1.7 requires thnt timber
fascias, plastic rainwater tanks & plastic downpipes must not be located within 900mm of an
adjoining dwelling, 1t also requires
that air-conditioning units are not located within 900!lllll of an
adjoining dwelling.
Page 2 out of4
[OCR of page images]
[Required Inspections & Building Conditions (Attachment A) Building Application No: 20071609}
Stage Inspections Inspection Agency |Contact for Jnspections
Footing Stage —_| Footing GMA Certification Group Phone 07 ~ 55 781622
Site Inspection GMA Certification Group Phone 07 - 55 781622
Slab Stage Slab GMA Certification Group Phone 07 ~ 55 781622
Frame Stage Frame GMA Certification Group Phone 07 - 55 781622
Final Stage Final GMA Certification Group Phone 07 - 55 781622
[Certifier's Standard Conditions
1
be
Oor
10
11
12
13
14
15
16
Notwithstanding anything stated in or omitted from the documentation submitted by the applicant or stated in or omitted from
these conditions, all work is to comply with the Building Act 1975, Building Regulation 2006, and the Planning Scheme for Noosa
Shire Council,
In issuing this permit GMA Certification Group Pty Ltd does not certify that the design is correct and does not assume any
responsibility for the correctness of the design.
Compliance with the Building Act 1975 and the relevant Planning Scheme is the responsibility of the applicant,
Building work approved on this building application has to be
(a) commenced within [ 12 ] months of approval
(b) finalised within [2 ] years of approval.
Further Development Permits Required -
* Development Approval Plumbing & Drainage Work
To satisfy the Building Certifier that the Building work has been constructed to an acceptable standard, the following
documentation will be required: (when relevant)
i) Certificate/s for footing and/or slab inspection/s of Class 1a building work where a competent person carries ont such
inspections as nominated in the building application submitted to and approved by the Building Certifier.
ii) Truss Manufacturer's Certificate, quoting the relevant wind classification,
iii) Engineer's certification for structural work not in accordance with Building Code of Australia, Volume 2 or manufacturer's
specification.
iv) Licensed Applicator's Certificate for Tennite Management in accordance with A.S.3660.1 - 2000 (Clause 3.1.3, BCA)
v) Glass suppliers certification of window glass to AS 1288 for wind velocity and AS 2208 (Part 3.6 BCA).
vi) Glass suppliers certification of shower screens to AS 2208,
vii) A certificate from a licensed applicator wet aveas is required, must comply with;
* AS 3740 - 1994
* Part 3.8.1- BCA.
viii) Certificate ftom a Licensed Electrician for the installation of Smoke Alanns in accordance with AS 3786 and BCA Part 3.7.2
ix) Certificate from a Licensed Electrician for the installation of Energy Efficient Lighting in accordance with Queensland
Development Code - Part 29,
x) Certificate for the installation of the Insulation as required by the Energy Efficiency Assessment, stating the Product name and
R-Value.
xi) Surveyors Setout certificate,
xii) Manufacturers certificate for Balustrades,
Waterproofing to wet areas (bathrooms, laundries and WC's) to comply with the requirements of the BCA3.8,1 and AS3740.
Smoke alarms to be provided in accordance with BCA 3.7.2 and AS 3786.
Surface Water, resulting from a stonn having an average reccurrence interval of 100 years must not enter the building. The Loca?
Government may hold records which provide information in relation to Flood levels, which may determine the minimum required
floor ievel. (It is the applicants responsibility to obtain any necessary data)
Retaining Walls - (If Applicable) Retaining walls over I metre high need building approval and an Engineer's Certificate for the
design,
Toilet doors are to be provided with lift-off hinges where pans are located within 1.2m of the door swing are.
The development is ta strictly comply with the 'conditions of approval’ issued by Noosa Council & which are attached to & form
part of its MCU Approval (File no.2004/5744 dated 15 December 2005), OW Approval (file no,20061015 dated 14 December
2006) & ROL Approval (file no.21645 dated 14 June 2002),
All internal Laundries not lighted by a window or skylight (10% of floor area with 5% openable) are to be artificailly lit &
mechanically ventilated,
Notwithstanding any of the information shown on the GMA endorsed & approved plans articulation joints are to be installed in
accordance with soil test & the structural design engincer’s requirements,
Notwithstanding any of the information shown on the GMA endorsed & approved plans all wall substrate material & flashings in
‘wet-areas' are to strictly comply with the requirements of AS3740.
The requirements of the BCA 3.7.1.10 requires roof lights not to be located closer than 1800mm in adjoining dwellings.
Installation details & unubridged fire tests/product approvals relating to the proposed glass block window's & articulation joint
treatment to be used in the walls fire separating dwellings need to be submitted for assessment. Cover strips in eave linings are to
be non-combustible where the dwelling walls are located less then 1.8m from one another, BCA 3.7, 1.7 requires that timber
fascias, plastic rainwater tanks & plastic downpipes must not be located within 900mm of an adjoining dwelling, It also requires
that air-conditioning units are not located within 900mm of an adjoining dwelling.
Page 2 out of 4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Request to Change an Application 132004.5744.03Related documentApplication case desk ↗
About this file
- File size
- 11.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.