Original source · versioned page text
Attachment D - Compiled Approved Plans 132004.5744.11 (2).pdf
COLOUR LEGEND
NOOSA COUNCIL
-
NOTES
TWO BEDROOM UNITS
Select Architects accept no responsibility for any costs, losses, claims
THREE BEDROOM UNITS APPROVED PLAN V5
howsoever arising from these drawings, specifications and related
documents unless there is full compliance with the client and any authorised
CIRCULATION AREAS 132004.5744.09 30 AUG 2017 FUTURE
user of the following:
SILV CHANGE V4 1. All boundaries, dimensions and levels are to be checked on site before
STORE ST
ER ROOMS
construction and any discrepancies are to be reported to the Architect /
EASEMENTS GU Designer.
LL B V3 2. Partial Service: Any discrepancies with site or other information is to be
advised to the Architect / Designer and direction or approval is to be sought
APPROX BOUNDARY LINE LVD before the implementation of the detail.
3. Block and site plans should be verified by a check boundary survey prior
FUTURE V2 to commencement on site.
4. Do not scale this drawing.
SWIMMING POOL 5. For the purpose of coordination, all relevant parties must check this
VISITOR PARKING (20M X 6M) information prior to implementation and report any discrepancies to the
V1 (5 SPACES) Architect / Designer.
V2 VISITOR PARKING
V3 V1 (5 SPACES) REV DATE DESCRIPTION DRN CHKD
P1 16.05.17 PLANNING REVIEW CM DO
V4
V5
PROPERTY DESCRIPTION
ST
FLOOR AREA (EXCLUDING DECKS AND
COURTYARD COURTYARD COURTYARD COURTYARD COURTYARD 1373m²
UM
OUTDOOR AREAS)
NO. OF TWO BEDROOM UNITS
EG
(GROUND FLOOR ONLY) 10
NO. OF THREE BEDROOM UNITS
BLU
(GROUND FLOOR ONLY) 2
ENTRY
TOTAL FLOOR AREA (EXCLUDING DECKS
COURTYARD COURTYARD 2637m²
AND OUTDOOR AREAS)
UP 6 5 4 8 9 UP TOTAL NO. OF TWO BEDROOM UNITS 20
TOTAL NO. OF THREE BEDROOM UNITS 4
NO. OF COVERED CAR PARKS (BLDG A
TENANTS) 24
GROUND FLOOR NO. OF OPEN CAR PARKS (BLDG A N
TENANTS) 4
FOYER
NO. OF CAR PARKS (VISITORS OVERALL) 10
UP CLIENT
LIFT
COUNTRY CLUB VILLAGES
7 3 2 1 10 11 12 PROJECT
COUNTRY CLUB VILLAGES
COURTYARD EENIE CREEK ROAD
NOOSAVILLE, QLD 4566
DRAWING
PROPOSED GROUND FLOOR PLAN
COURTYARD COURTYARD COURTYARD COURTYARD COURTYARD COURTYARD COURTYARD
(BUILDING A)
7B
Level 3 117 Myers Street Geelong VIC 3220 AUSTRALIA
T: +61 3 5224 7300 F: +61 3 8621 0087
Level 2 390 St Kilda Road Melbourne VIC 3004 AUSTRALIA
T: +61 3 9860 1900 F: +61 3 8621 0087
135 Greenhill Road, Unley SA 5061 AUSTRALIA
7A 3 2 1 4 5 19A 19B 6 13 14 15 16 24A 24B 17 20 21 22 23 12A 12B 8 9 10 11 18 T: +61 8 8291 9600 F: +61 8 7221 2816
[email protected]
www.select-group.com.au
Select Architects Pty Ltd ABN: 60 120 640 349
TENANT PARKING
Director: Peter Serra RAIA - Architect Reg: 15818
(28 SPACES)
DRAWN CHECKED SCALE
ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST CM DO 1:250
DATE PROJECT No STATUS
MAY 2017 G1649 TP
1 PROPOSED GROUND FLOOR PLAN (BUILDING A) DRAWING No REV
- SCALE 1:250
TP-02 P1
Preview the original