Original source · versioned page text
Bushfire Hazard Assessment - 11 Senegal Rise
4.0 LOCAL HAZARD MAP 4.1 GENERAL The SPP reference documentation sets out the following methodology for preparing a Local Hazard Area Map: • Categorising the vegetation within the site in accordance with the vegetation hazard classes derived from QFES (2019) • Using the patch and corridor filtering process to remove narrow corridors and small patches of hazardous vegetation • Subdividing the identified vegetation hazard classes into bushfire hazard sub-units based on slope differences and vegetation hazard classes • Assigning SPP Potential Bushfire Intensity classes to the sub-units • Application of 100m Potential Impact Buffers to the amended sub-units to derive an overall Local Hazard Map. 4.2 PATCH AND CORRIDOR FILTERING Section 4.2.6 of Bushfire Resilient Communities (QFES (2019) outlines the patch and corridor filtering process to modify potential intensity of small patches and corridors (based on Leonard et. al. 2017). The process involves the following three stages: • Merging small patches of a single Vegetation Hazard Class less than 0.5 ha; • Merging small Vegetation Hazard Class patches between 0.5 and 1 ha with higher or moderate fuel loads (greater than 8 tonnes/ha); and • Removing narrow corridors of vegetation less than 50m wide through a process of patch erosion and dilation. These small patches are merged with surrounding vegetation by allocating a patch to the Vegetation Hazard Class that is most common to the patch boundary (Leonard et al., 2017). 4.3 CALCULATION OF POTENTIAL BUSHFIRE INTENSITY Potential Bushfire Intensity is calculated by inputting the site-specific input parameters discussed in Section 3.1 into the FLAMESOL computer model. FLAMESOL uses industry standard bushfire equations and allows numerous input variables to be adjusted including fuel loads, fire danger index, site slope and distance to vegetation. The table below details the Potential Bushfire Intensity classes and their corresponding potential fire-line intensity (KW/m) values as prescribed within Leonard et. al. 2017. POTENTIAL BUSHFIRE INTENSITY POTENTIAL FIRELINE INTENSITY Very High >40,000 kW/m High 20,000-39,999 kW/m Medium 4,000 – 19,999 kW/m Figures 5-7 are presented below and have been prepared as per the above referenced methodology. 19 July 2021 Chris Bentley Page: 7 Job No. 20-052 Bushfire Hazard Assessment – 11 Senegal Rise, Doonan
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.