Skip to the record
For the highest quality transcripts.

Council archive · source document

Town Planning Report · MCU13/0102

of 26

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Sunshine Coast Office
| Innovation Parkway, Birtinya, PO Box 149,Wurtulla QLD Australia 4575
+6] 7 5436 7888 F +61 7 5493 6630 E [email protected] W rpsgroup.com.au

Our Ref: PR114330-3.1001MF.Ip
Date: 29"" May 2013
The Chief Executive Officer

Sunshine Coast Regional Council
Locked bag 72
SCMC QLD 4560

Dear Sir/ Madam

RE: APPLICATION FOR MATERIAL CHANGE OF USE - NINE (9) DETACHED
HOUSES, PROPOSED LOTS 41, 42, 57, 89, 90, 91, 92, & 93 SMOKE BUSH
DRIVE, NOOSA HEADS, ELYSIUM NOOSA PTY LTD

We act on behalf of the applicant AVJennings, in relation to the abovementioned
Development Application.

Enclosed for your receipt and assessment is the following application documentation:-

IDAS Form 1 - Application Details;

IDAS Form 5 — Material Change of Use Assessable Against a Planning Scheme;
Proposal Plans prepared by AV Jennings;

Cheque made payable to Sunshine Coast Regional Council in the sum of $2,277
being the mandatory application fees;

Email correspondence dated 24 April 2013; and

e Proposed Community Titles Subdivision Lot Calculations Plan, Plan No. 6994-26Q,
dated 24-10-2004.

Under Section 261(A) of the Sustainable Planning Act 2009, this application is properly made.
This letter outlines the details of the proposal, and the proposal’s compliance with the Noosa
Plan and the approved Master Plan for Elysium Noosa.

PROPOSAL

Details of the site and the proposal are summarised as follows:

 

Street Address: Smoke Bush Drive, Noosa

 

Real Property Description: Lot 503 on SP251598 & Lots 90-93 on SP251598

 

Proposal: Nine (9) Detached Houses, being located on Proposed Lots 58-61 and Lots 84-
88within the Elysium residential development.

 

Land Area:

Lot 58 -518m?
Lot 59 - 522m?
Lot 60 - 532m?
Lot 61 — 585m?
Lot 84 - 579m?

Lot 85 — 570m?
Lot 86 -— 562m?
Lot 87 — 553m?
Lot 88 — 553m?

APONn>
Oana

 

 

Zoning: Detached Housing Precinct

 

Previous Approvals:

Material Change of Use Non-Urban to Special Residential for 196 Dwellings and Lot
Reconfiguration Creation of 100 lots (inc 99 conventional lots and 6 group title lots) Ref:
23245 DA dated 29 April 2004

 

Development Permit Material Change of Use & Preliminary Reconfiguration of a Lot Ref:

 

 

England | Wales | Scotland | Northern Ireland [ Ireland | Netherlands | USA | Australia Page 1 of 26

APS Austraia East Pty Ltd ABN 44 (40 292 762 A member of the RPS Group Plc
Full text of the other 25 pages

Page 2

 

 

2003/220735 (23245 DA) dated 28 October 2005

Development Permit Reconfiguration of a Lot Approval Ref: 2005/170 dated 3 November
2005

Plan of Development ~ ‘Elysium Sunset Drive, Noosa Springs Road’ - Group housing
development in accordance with Approved Plans 6994.53C.dwg Revision C (C23245 DA)

Development Permit Material Change of Use (8 x Detached Houses) Ref: MCU12/0144 dated
5 November 2012

 

The proposal is for the establishment of nine (9) Detached Houses located within the Elysium
tesidential development. The Detached Houses are to be located on the abovementioned
proposed allotments with a single house located on each of these allotments.

1.1 Dwelling House Design Characteristics

The details of the nine (9) Detached Houses are depicted in the Elevations and Floor Plans
as attached to this report (refer Attachment 1).

The Detached Houses are characterised by the following design features that provide the
highest standards of quality and amenity: -

Substantial areas of private open space;

Internal courtyards,

Extensive covered outdoor areas;

High quality finishes;

Open plan arrangements; and

Careful attention paid to articulation on all elevations.

In addition, careful consideration has been given to the ‘sustainability’ components, including
the following: -

e High level natural light;

e Ventilation through louvered clerestories;

e Most dwellings situated with a northerly aspect for summer and winter courtyard
living;

Sun screening with use of motorised and stationary sun blades;

Pivoting sun blades that adjust for wind control;

Incorporation of solar panels and solar hot water services;

Extensive use of endemic subtropical landscaping: and

Cross-ventilation as a fundamental consideration in all designs.

2. COMPLIANCE WITH PLANNING SCHEME AND EARLIER APPROVALS

Pursuant to The Noosa Pian, the site is included within the Noosa Heads Locality Plan and
located in the Detached Housing Precinct. Further, the site is subject to the associated Plan
of Development for Elysium Noosa, under Group Housing Development in accordance with
Approved Plans 6994.53C.dwg Revision C (Council Reference C23245 DA).

As specified in the Supplementary Table of Development Plan on the Plan of Development
(where the development parameters are predicted), the proposal will be ‘Development to
follow a Code Assessment Process’.

For the purposes of this assessment, ‘setback’ and ‘site cover’ is defined in accordance with
‘Part 2 — Interpretation and Dictionary’ of The Noosa Plan.

Page 2 of 26

 

Page 3

setback means the minimum distance from any /ot boundary to a building or structure,
excluding eaves, roof overhangs and awnings provided they encroach no more than 600mm
into the setback distance.

site cover means the proportion of a site covered by all buildings and structures shown as a
percentage. For enclosed spaces this includes the area within the outside wall and for
unenclosed spaces this includes the area measured along a line 600mm in from the perimeter
of the roof. Site cover includes garages and other roofed outbuildings, but does not include
landscape structures such as in-ground pools and decks. It is noted that the site cover stated
on the Proposal Plans includes the full roof area of the salas without making any allowance
for the permitted 600mm intrusion and hence they are overstated.

Please note, the Plan of Development notates that all dimensions and areas are approximate
only, and are subject to survey and Council approval, as such, the Proposal Plans have been
prepared in respect of the most recent Lot Caiculations Plan which accurately represents all
lot areas. Further, the Lot Calculation Plan identifies a 1-2m? increase in lot area to lots 84-88,
in comparison to the Plan of Development, which is considered negligible in the context of
calculating site cover.

2.1 Compliance with Elysium Master Plan (Key Development Requirements)

The approved Plan of Development for Elysium Noosa provides key development
requirements for a range of uses. The key development requirements table on the approved
Plan of Development indicates the general requirements for all Group Housing Development
precinct residential lots.

The provisions of the Key Development Requirements for Precincts are considered below:

Allotment 58

Key Requirements
Group Housing Development Precinct

Private Open Space
Entry Lots 901/902:

e No Dwellings or Structures other
than depicted in the approval
landscape plan are to be erected or
otherwise installed on these lots.

e Maintenance agreement to be
included in all bodies corporate to
ensure ongoing maintenance of
entrance features.

Group Housing Lots 94 & 99:
e Dwelling units within lot 94 & 99,
adjacent to the entry road, are to be
set back a minimum of 6 metres.

Compliant
No dwellings or Structures are proposed to be

erected on lots 901, 902, 94 & 99 as part of
this proposal.

 

General

General requirements for all group Housing
Development Precinct Residential Lots:

All buildings shall be screened where
practical to prevent the ingress of
mosquitoes and smaller biting midges.

Compliant
Screening requirements to be conditioned.

 

Site Cover
The maximum site cover for any lot shall not
exceed:

e 50% for ground floor; and

 

 

Compliant

The proposal is configured over one (1) storey
and comprises a total site cover of 46.7%,
less than the prescribed 50% site cover for

 

Page 3 of 26

 

Page 4

 

e 40% for First Floor to achieve a
steeping of buildings.

the ground floor.

 

Front Setbacks

Alllots shall have a minimum front setback of
3 metres, with garages setback a minimum
of 4.5m, with minor intrusions permitted of
eaves, covered entrances and the like.
Where a lesser setback than 5.4m is
proposed to garages:

e Provision shall be given for visitor
parking on the driveway with a
minimum length of 5.4 metres,
measured form the garage and a 3.0
metre separation from the back of
kerb to the rear of a parked vehicle
maintained.

e The sightline requirements to the
footpath shall be maintained in
accordance with AS2890.1-2004, for
vehicles parked on the proposed
driveways.

e Front and side setbacks are to be
measured from the facade (face of
building) to the boundary.

Where the boundary alignment is non linear
or irregular, for example corner blocks or cul
de sac, the setback shall be calculated as an
average distance along the length of the
facade (face of the building) or garage
alignment, which ever applies.

Garages shall be setback in line with the
main dwelling facade or behind the main
dwelling facade.

Compliant
The proposed dwelling is in accordance with

requirements and includes a minimum 5m
setback measured from the boundary to the
front building line and a 4.5m_ setback
measured from the boundary to the garage.
Further, the provision of a cross over
measured approximately 5m from the
boundary to the street frontage enables visitor
parking on the driveway. We confirm that the
proposed garage is setback behind with the
main dwelling facade.

 

Secondary Frontage (corner allotments)
The minimum setback from the secondary
street frontage shall be 3.0m. Windows,
balconies, verandas and screening devices
are to be incorporated into elevations facing
street frontages to articulate building form.
Laundries and clothes-drying facilities are
not to be located along the primary or
secondary street frontage, unless suitable
screening is provided.

Compliant
The proposal is not for a corner allotment.

Notwithstanding, the proposal includes
perimeter fencing and landscaped treatments.
Further, the proposal contains high quality
building design and materials to articulate the
building form, including the incorporation of
screening devices such as aluminium louvers
on the building facade, refer to Proposal
Plans prepared by AV Jennings located at
Appendix A.

 

 

Rear Setbacks

The minimum rear building setback shall be
2metres, with minor intrusions permitted for
eaves and the like.

Buildings shall be setback a minimum of 6m
from the Conservation Parkland boundary,
with minor intrusions permitted of eaves and
the like.

Swimming pools, pergolas, low decks and
garden structures shall be setback a
Minimum of 2m from the Conservation

 

Compliant
The proposal includes a 3m_ setback

measured from the rear property boundary to
the building line.

The proposal is not sited adjacent to or abuts
the Conservation Parkland boundary.

 

Page 4 of 26

 

Page 5

 

Parkland boundary, with minor intrusions
permitted where footings do not adversely
impact on vegetation within the Conservation
Parkland to the reasonable satisfaction of the
Manager Land Use.

 

Built to Boundary Walls_and_ Side
Setbacks

All lots containing built to boundary walls
shall provide a minimum side setback of 3m
measured for the building fagade to one of
the boundaries to ensure open space is
maintained between each of the dwelling
units.

Where no built to boundary walls are
identified by the building envelope on the lot,
buildings shall be setback a minimum of
1.5m from one side boundary.

The maximum length of Built to Boundary
walls is 8.0m, built within a maximum of 15m
from the front boundary alignment.

The maximum height of a built to boundary
wall is 3.5m and is to be constructed with
materials consistent with the remainder of
the dwelling.

Built to boundary walls are permitted on lots
less than 600m2 and all lots which abut
conservation parklands.

Acceptable Solution

It is recognised that built to boundary walls
are permitted on lots less than 600m2, and is
therefore applicable to this lot.

The garage is built to boundary, whilst a 2.6m
side setback is provided to the balance of the
southern boundary and a 5.2m side setback is
provided to the northern boundary.

It is noted however that the roof of the sala
extends 1.6m into the northern side setback.
By definition the sala is permitted to encroach
up to 600mm into the side setback. It is our
view that the design as submitted achieves an
acceptable amenity outcome.

Additionally, because each of the houses are
clustered together for approval of the designs
as submitted, all purchasers of lots will be
making their purchaser decision in full
knowledge of the approved setbacks of the
adjoining lots.

The maximum length of the garage wall built
to the boundary is 6m within a maximum of
15m from the front boundary alignment. The
maximum height of the built to boundary wall
is 2.7m.

 

 

Building Height

Except for Lots 1-5, 9, 10 & 13 that shall not
exceed 1 storey, the maximum _ building
height of 2 storeys and 8 metres applies, in
accordance with the Schedule to the
Planning Scheme for Noosa Shire shall

apply.

Estate Sales Office:

Any Estate Sales Office or Display Home
must comply with the provisions of section
5.14 of the Transitional Planning Scheme for
Noosa Shire.

Community Use Facilities:

Community Use Facilities are to be located
in accordance with this Plan of Development
and are to be developed generally in
accordance with the Community Centre
proposal plans prepared by AV Jennings
Plans SKO1A (Feb 11), SKO2 (Feb 11) &
SKO3 (Feb 11).

 

Compliant
The proposed dwelling is configured over one
(1) storey and is below the 8m height limit.

 

Page 5 of 26

 

Page 6

Allotment §9

   

Key Requirements

Group Housing Development Precinct

Private Open Space

Entry Lots 901/902:

e No Dwellings or Structures other
than depicted in the approval
landscape plan are to be erected or
otherwise installed on these lots.

« Maintenance agreement to be
included in all bodies corporate to
ensure ongoing maintenance of
entrance features.

Group Housing Lots 94 & 99:
e Dwelling units within lot 94 & 99,
adjacent to the entry road, are to be
set back a minimum of 6 metres.

Compliant
No dwellings or Structures are proposed to be

erected on lots 901, 902, 94 & 99 as part of
this proposal.

 

General

General requirements for all group Housing
Development Precinct Residential Lots:

All buildings shall be screened where
practical to prevent the ingress of
mosquitoes and smaller biting midges.

Compliant
All proposed buildings will be screened where
practical.

 

Site Cover
The maximum site cover for any lot shall not
exceed:
e« 50% for ground floor; and
e 40% for First Floor to achieve a
steeping of buildings.

Compliant
The proposal is configured over one (1) storey

and comprises a total site cover of 46.4%,
less than the prescribed 50% site cover for
the ground floor.

 

Eront Setbacks

Alllots shall have a minimum front setback of
3 metres, with garages setback a minimum
of 4.5m, with minor intrusions permitted of
eaves, covered entrances and the like.
Where a lesser setback than 5.4m _ is
proposed to garages:

e Provision shall be given for visitor
parking on the driveway with a
minimum length of 5.4 metres,
measured form the garage and a 3.0
metre separation from the back of
kerb to the rear of a parked vehicle
maintained.

e The sightline requirements to the
footpath shall be maintained in
accordance with AS2890.1-2004, for
vehicles parked on the proposed
driveways.

e Front and side setbacks are to be
Measured from the facade (face of

 

 

Compliant
The proposed dwelling is in accordance with

requirements and includes a minimum 3m
setback measured from the boundary to the
front building line and a 4.5m _ setback
measured from the boundary to the garage.
Further, the provision of a cross over
measured approximately 5m from the
boundary to the street frontage enables visitor
parking on the driveway. We confirm that the
proposed garage is setback behind with the
main dwelling facade.

 

 

Page 6 of 26

Page 7

 

building) to the boundary.

Where the boundary alignment is non linear
or irregular, for example corner blocks or cul
de sac, the setback shall be calculated as an
average distance along the length of the
facade (face of the building) or garage
alignment, which ever applies.

Garages shall be setback in line with the
main dwelling facade or behind the main
dwelling facade.

 

Secondary Frontage (corner allotments)
The minimum setback from the secondary
street frontage shall be 3.0m. Windows,
balconies, verandas and screening devices
are to be incorporated into elevations facing
street frontages to articulate building form.
Laundries and clothes-drying facilities are
not to be located along the primary or
secondary street frontage, unless suitable
screening is provided.

Compliant
The proposal is not for a corner allotment.

Notwithstanding this, the proposal includes
perimeter fencing and landscaped treatments.
Further, the proposal contains high quality
building design and materials to articulate the
building form, including the incorporation of
screening devices such as aluminium louvers
on the building facade, refer to Proposal
Plans prepared by AV Jennings located at
Appendix A.

 

Rear Setbacks

The minimum rear building setback shall be
2metres, with minor intrusions permitted for
eaves and the like.

Buildings shall be setback a minimum of 6m
from the Conservation Parkland boundary,
with minor intrusions permitted of eaves and
the like.

Swimming pools, pergolas, low decks and
garden structures shall be setback a
minimum of 2m from the Conservation
Parkland boundary, with minor intrusions
permitted where footings do not adversely
impact on vegetation within the Conservation
Parkland to the reasonable satisfaction of the
Manager Land Use.

Compliant
The proposal includes a 3m_ setback

measured from the rear property boundary to
the building line.

The proposal is not sited adjacent to or abuts
the Conservation Parkland boundary.

 

 

Built to Boundary Walls and_ Side
Setbacks

All lots containing built to boundary walls
shall provide a minimum side setback of 3m
measured for the building fagade to one of
the boundaries to ensure open space is
maintained between each of the dwelling
units.

Where no built to boundary walls are
identified by the building envelope on the lot,
buildings shall be setback a minimum of
1.5m from one side boundary.

The maximum length of Built to Boundary
walls is 8.0m, built within a maximum of 15m
from the front boundary alignment.

The maximum height of a built to boundary
wall is 3.5m_and is to be constructed with

 

Acceptable Solution

It is recognised that built to boundary walls
are permitted on lots less than 600m2, and is
therefore applicable to this lot.

The garage is built to boundary, whilst a 2.6m
side setback is provided to the balance of the
southern boundary and a 6.4m side setback is
provided to the northern boundary.

It is noted however that the roof of the sala
extends 100mm into the northern side
setback. By definition the sala is permitted to
encroach up to 600mm into the side setback.
It is our view that the design as submitted
achieves an acceptable amenity outcome.

Additionally, because each of the houses are
clustered together for approval of the designs

 

Page 7 of 26

 

Page 8

 

materials consistent with the remainder of
the dwelling.

Built to boundary walls are permitted on lots
less than 600m2 and all lots which abut
conservation parklands.

as submitted, all purchasers of lots will be
making their purchaser decision in full
knowledge of the approved setbacks of the
adjoining lots.

Further, the maximum length of the garage
wall built to the boundary is 6m within a
maximum of 15m from the front boundary
alignment. The maximum height of the built to
boundary wall is 2.7m.

 

Building Height
Except for Lots 1-5, 9, 10 & 13 that shall not

exceed 1 storey, the maximum building
height of 2 storeys and 8 metres applies, in
accordance with the Schedule to the
Planning Scheme for Noosa Shire shall

apply.

Estate Sales Office:

Any Estate Sales Office or Display Home
must comply with the provisions of section
5.14 of the Transitional Planning Scheme for
Noosa Shire.

Community Use Facilities:

Community Use Facilities are to be located
in accordance with this Plan of Development
and are to be developed generally in
accordance with the Community Centre
proposal plans prepared by AV Jennings
Plans SKO1A (Feb 11), SKO2 (Feb 11) &
SKO3 (Feb 11).

 

 

Compliant
The proposed dwelling is configured over one
(1) storey and is below the 8m height limit.

 

 

Allotment 60

Key Requirements
Group Housing Development Precinct

Private Open Space
Entry Lots 901/902:

e No Dwellings or Structures other
than depicted in the approval
landscape plan are to be erected or
otherwise installed on these lots.

e Maintenance agreement to be
included in all bodies corporate to
ensure ongoing maintenance of
entrance features.

Group Housing Lots 94 & 99:
e Dwelling units within lot 94 & 99,
adjacent to the entry road, are to be
set back a minimum of 6 metres.

Compliant
No dwellings or Structures are proposed to be

erected on lots 901, 902, 94 & 99 as part of
this proposal.

 

General

General requirements for all group Housing
Development Precinct Residential Lots:

All buildings shall be screened where
practical to prevent the ingress of

 

 

Compliant
All proposed buildings will be screened where

practical.

 

 

Page 8 of 26

Page 9

 

mosquitoes and smaller biting midges.

 

Site Cover
The maximum site cover for any lot shall not
exceed:
e 50% for ground floor; and
« 40% for First Floor to achieve a
steeping of buildings.

Compliant
The proposal is configured over one (1) storey

and comprises a total site cover of 45.5%,
less than the prescribed 50% site cover for
the ground floor.

 

Front Setbacks

Alllots shall have a minimum front setback of
3 metres, with garages setback a minimum
of 4.5m, with minor intrusions permitted of
eaves, covered entrances and the like.
Where a lesser setback than 5.4m is
proposed to garages:

e Provision shall be given for visitor
parking on the driveway with a
minimum length of 5.4 metres,
measured form the garage and a 3.0
metre separation from the back of
kerb to the rear of a parked vehicle
maintained.

e The sightline requirements to the
footpath shall be maintained in
accordance with AS2890.1-2004, for
vehicles parked on the proposed
driveways.

e Front and side setbacks are to be
measured from the facade (face of
building) to the boundary.

Where the boundary alignment is non linear
or irregular, for example corner blocks or cul
de sac, the setback shall be calculated as an
average distance along the length of the
facade (face of the building) or garage
alignment, which ever applies.

Garages shall be setback in line with the
main dwelling facade or behind the main
dwelling facade.

Compliant

The proposed dwelling is in accordance with
requirements and includes a minimum 3m
setback measured from the boundary to the
front building line, with the exception of a
minor protrusion of the building wall.

Further, a 5m setback is provided measured
from the boundary to the garage. In addition,
the provision of a cross over measured
approximately 5m from the boundary to the
street frontage enables visitor parking on the
driveway. We confirm that the proposed
garage is setback behind with the main
dwelling facade.

 

Secondary Frontage (corner allotments)
The minimum setback from the secondary
street frontage shall be 3.0m. Windows,
balconies, verandas and screening devices
are to be incorporated into elevations facing
street frontages to articulate building form.
Laundries and clothes-drying facilities are
not to be located along the primary or
secondary street frontage, unless suitable
screening is provided.

Compliant
The proposal is not for a corner allotment.

Notwithstanding this, the proposal includes
perimeter fencing and landscaped treatments.
Further, the proposal contains high quality
building design and materials to articulate the
building form, including the incorporation of
screening devices such as aluminium louvers
on the building facade, refer to Proposal
Plans prepared by AV Jennings located at
Appendix A.

 

 

Rear Setbacks

The minimum rear building setback shall be
2metres, with minor intrusions permitted for
eaves and the like.

Buildings shall be setback a minimum of 6m
from the Conservation Parkland boundary,

 

Compliant

The proposal includes a 3m_ setback
measured from the rear property boundary to
the building line.

The proposal is not sited adjacent to or abuts
the Conservation Parkland boundary.

 

Page 9 of 26

 

Page 10

 

with minor intrusions permitted of eaves and
the like.

Swimming pools, pergolas, low decks and
garden structures shall be setback a
minimum of 2m from the Conservation
Parkland boundary, with minor intrusions
permitted where footings do not adversely
impact on vegetation within the Conservation
Parkland to the reasonable satisfaction of the
Manager Land Use.

 

Built to Boundary Walls
Setbacks

All lots containing built to boundary walls
shall provide a minimum side setback of 3m
measured for the building fagade to one of
the boundaries to ensure open space is
maintained between each of the dwelling
units.

and_ Side

Where no built to boundary walls are
identified by the building envelope on the lot,
buildings shall be setback a minimum of
1.5m from one side boundary.

The maximum length of Built to Boundary
walls is 8.0m, built within a maximum of 15m
from the front boundary alignment.

The maximum height of a built to boundary
wall is 3.5m and is to be constructed with
materials consistent with the remainder of
the dwelling.

Built to boundary walls are permitted on lots
less than 600m2 and all lots which abut
conservation parklands.

Acceptable Solution

It is recognised that built to boundary walls
are permitted on lots less than 600m2, and is
therefore applicable to this lot.

The garage is built to boundary, whilst a 2.6m
side setback is provided to the balance of the
southern boundary and a 6.4m side setback is
provided to the northern boundary.

It is noted however that the roof of the sala
extends 100mm into the northern side
setback. By definition the sala is permitted to
encroach up to 600mm into the side setback.
It is our view that the design as submitted
achieves an acceptable amenity outcome.

Additionally, because each of the houses are
clustered together for approval of the designs
as submitted, all purchasers of lots will be
making their purchaser decision in full
knowledge of the approved setbacks of the
adjoining lots.

Furthermore, the maximum length of the
garage wall built to the boundary is 6m within
a maximum of 15m from the front boundary
alignment. The maximum height of the built to
boundary wall is 2.7m.

 

 

Building Height
Except for Lots 1-5, 9, 10 & 13 that shall not

exceed 1 storey, the maximum building
height of 2 storeys and 8 metres applies, in
accordance with the Schedule to the
Planning Scheme for Noosa Shire shall

apply.

Estate Sales Office:

Any Estate Sales Office or Display Home
must comply with the provisions of section
5.14 of the Transitional Planning Scheme for
Noosa Shire.

Community Use Facilities:

Community Use Facilities are to be located
in accordance with this Plan of Development
and are to be developed generally in

 

Compliant
The proposed dwelling is configured over one
(1) storey and is below the 8m height limit.

 

Page 10 of 26

 

Page 11

 

accordance with the Community Centre
proposal plans prepared by AV Jennings
Plans SKO1A (Feb 11), SKO2 (Feb 11) &
SKO3 (Feb 11).

 

 

 

Allotment 61

 

Key Requirements
Group Housing Development Precinct

Private Open Space
Entry Lots 901/902:
e No Dwellings or Structures other

than depicted in the approval
landscape plan are to be erected or
otherwise installed on these lots.

e Maintenance agreement to be
included in all bodies corporate to
ensure ongoing maintenance of
entrance features.

Group Housing Lots 94 & 99:
e Dwelling units within lot 94 & 99,
adjacent to the entry road, are to be
set back a minimum of 6 metres.

Compliant
No dwellings or Structures are proposed to be

erected on lots 901, 902, 94 & 99 as part of
this proposal.

 

General

General requirements for all group Housing
Development Precinct Residential Lots:

All buildings shall be screened where
practical to prevent the ingress of
mosquitoes and smaller biting midges.

Compliant
All proposed buildings will be screened where

practical.

 

Site Cover
The maximum site cover for any lot shall not
exceed:
e 50% for ground floor; and
e 40% for First Floor to achieve a
steeping of buildings.

Compliant

The proposal is configured over one (1) storey
and comprises a total site cover of 46.3%,
less than the prescribed 50% site cover for
the ground floor.

 

Front Setbacks

Alllots shall have a minimum front setback of
3 metres, with garages setback a minimum
of 4.5m, with minor intrusions permitted of
eaves, covered entrances and the like.
Where a lesser setback than 5.4m _ is
proposed to garages:

e Provision shall be given for visitor
parking on the driveway with a
minimum length of 5.4 metres,
measured form the garage and a 3.0
metre separation from the back of
kerb to the rear of a parked vehicle
maintained.

e The sightline requirements to the
footpath shall be maintained in
accordance with AS2890.1-2004, for
vehicles parked on the proposed
driveways.

e Front and side setbacks are to be

 

 

Compliant
The proposed dwelling is in accordance with

requirements and includes a minimum 3m
setback measured from the boundary to the
front building line and a 4.5m setback from
the boundary to the garage. In addition, the
provision of a cross over measured
approximately 5m from the boundary to the
street frontage enables visitor parking on the
driveway. We confirm that the proposed
garage is setback behind with the main
dwelling facade.

 

 

Page 11 of 26

Page 12

 

measured from the facade (face of
building) to the boundary.

Where the boundary alignment is non linear
or irregular, for example corner blocks or cul
de sac, the setback shall be calculated as an
average distance along the length of the
facade (face of the building) or garage
alignment, which ever applies.

Garages shall be setback in line with the
main dwelling facade or behind the main
dwelling facade.

 

Secondary Frontage (corner allotments)
The minimum setback from the secondary
street frontage shall be 3.0m. Windows,
balconies, verandas and screening devices
are to be incorporated into elevations facing
street frontages to articulate building form.
Laundries and clothes-drying facilities are
not to be located along the primary or
secondary street frontage, unless suitable
screening is provided.

Compliant
The proposal is not for a corner allotment.

Notwithstanding this, the proposal includes
perimeter fencing and landscaped treatments.
Further, the proposal contains high quality
building design and materials to articulate the
building form, including the incorporation of
screening devices such as aluminium louvers
on the building facade, refer to Proposal
Plans prepared by AV Jennings located at
Appendix A.

 

Rear Setbacks

The minimum rear building setback shall be
2metres, with minor intrusions permitted for
eaves and the like.

Buildings shall be setback a minimum of 6m
from the Conservation Parkland boundary,
with minor intrusions permitted of eaves and
the like.

Swimming pools, pergolas, low decks and
garden structures shall be setback a
minimum of 2m from the Conservation
Parkland boundary, with minor intrusions
permitted where footings do not adversely
impact on vegetation within the Conservation
Parkland to the reasonable satisfaction of the
Manager Land Use.

Compliant

The proposal includes a 3m_ setback
measured from the rear property boundary to
the building line.

The proposal is not sited adjacent to or abuts
the Conservation Parkland boundary.

 

 

Built to Boundary Walls and_ Side
Setbacks

All lots containing built to boundary walls
shall provide a minimum side setback of 3m
measured for the building fagade to one of
the boundaries to ensure open space is
maintained between each of the dwelling
units.

Where no built to boundary walls are
identified by the building envelope on the lot,
buildings shall be setback a minimum of
1.5m from one side boundary.

The maximum length of Built to Boundary
walls is 8.0m, built within a maximum of 15m
from the front boundary alignment.

The maximum height of a built to boundary

 

Compliant

A 1.5m side setback is provided to the
northern boundary, whist a 6.2m side setback
is provided to the southern boundary tapering
down to 1.3m at the south-western corner of
the site. This is considered to be a minor non-
compliance and applies approximately to 1m
of the wall length.

 

Page 12 of 26

 

Page 13

 

wall is 3.5m and is to be constructed with
materials consistent with the remainder of
the dwelling.

Built to boundary walls are permitted on lots
less than 600m2 and all lots which abut
conservation parklands.

 

Building Height

Except for Lots 1-5, 9, 10 & 13 that shall not
exceed 1 storey, the maximum building
height of 2 storeys and 8 metres applies, in
accordance with the Schedule to the
Planning Scheme for Noosa Shire shall

apply.

Estate Sales Office:

Any Estate Sales Office or Display Home
must comply with the provisions of section
5.14 of the Transitional Planning Scheme for
Noosa Shire.

Community Use Facilities:

Community Use Facilities are to be located
in accordance with this Plan of Development
and are to be developed generally in
accordance with the Community Centre
proposal plans prepared by AV Jennings
Plans SKO1A (Feb 11), SKO2 (Feb 11) &
SKO3 (Feb 11).

 

 

Compliant
The proposed dwelling is configured over one
(1) storey and is below the 8m height limit.

 

 

Allotment 84

Key Requirements
Group Housing Development Precinct

Private Open Space

Entry Lots 901/902:
¢ No Dwellings or Structures other
than depicted in the approval

landscape plan are to be erected or
otherwise installed on these lots.

e Maintenance agreement to be
included in all bodies corporate to
ensure ongoing maintenance of
entrance features.

Group Housing Lots 94 & 99:
e Dwelling units within lot 94 & 99,
adjacent to the entry road, are to be
set back a minimum of 6 metres.

Compliant

No dwellings or Structures are proposed to be
erected on lots 901, 902, 94 & 99 as part of
this proposal.

 

General

General requirements for all group Housing
Development Precinct Residential Lots:

All buildings shall be screened where
practical to prevent the ingress of
mosquitoes and smaller biting midges.

Compliant
All proposed buildings will be screened where
practical.

 

 

Site Cover

 

 

Compliant

 

Page 13 of 26

Page 14

 

The maximum site cover for any lot shall not
exceed:
e 50% for ground floor; and
e 40% for First Floor to achieve a
steeping of buildings.

The proposal is configured over one (1) storey
and comprises a total site cover of 50%.

 

Front Setbacks

All lots shall have a minimum front setback of
3 metres, with garages setback a minimum
of 4.5m, with minor intrusions permitted of
eaves, covered entrances and the like.
Where a lesser setback than 5.4m _ is
proposed to garages:

e Provision shall be given for visitor
parking on the driveway with a
minimum length of 5.4 metres,
measured form the garage and a 3.0
metre separation from the back of
kerb to the rear of a parked vehicle
maintained.

e The sightline requirements to the
footpath shall be maintained in
accordance with AS2890.1-2004, for
vehicles parked on the proposed
driveways.

e Front and side setbacks are to be
measured from the facade (face of
building) to the boundary.

Where the boundary alignment is non linear
or irregular, for example corner blocks or cul
de sac, the setback shall be calculated as an
average distance along the length of the
facade (face of the building) or garage
alignment, which ever applies.

Garages shall be setback in line with the
main dwelling facade or behind the main
dwelling facade.

Compliant
The proposed dwelling is in accordance with
requirements and includes a 3m _ setback
measured from the boundary to the front
building line.

It is noted that there is adequate space for
visitor parking on the driveway without
impeding on traffic along Bumpy Ash Lane,
which generates minimal traffic movement
and services lots 100-102 only.

We confirm that the proposed garage is
setback in line with the main dwelling facade.

 

Secondary Frontage (corner allotments)
The minimum setback from the secondary
street frontage shall be 3.0m. Windows,
balconies, verandas and screening devices
are to be incorporated into elevations facing
street frontages to articulate building form.
Laundries and clothes-drying facilities are
not to be located along the primary or
secondary street frontage, unless suitable
screening is provided.

Compliant
The proposal is not for a corner allotment.

Notwithstanding this, the proposal includes
perimeter fencing and landscaped treatments.
Further, the proposal contains high quality
building design and materials to articulate the
building form, including the incorporation of
screening devices such as aluminium louvers
on the building facade, refer to Proposal
Plans prepared by AV Jennings located at
Appendix A.

 

 

Rear Setbacks

The minimum rear building setback shall be
2metres, with minor intrusions permitted for
eaves and the like.

Buildings shall be setback a minimum of 6m
from the Conservation Parkland boundary,
with minor intrusions permitted of eaves and
the like.

Swimming pools, pergolas, low decks and

 

Compliant

The proposal includes a 5.9m setback
measured from the rear property boundary to
the building line.

The proposal is not sited adjacent to or abuts
the Conservation Parkland boundary.

 

Page 14 of 26

 

Page 15

 

garden structures shall be setback a
minimum of 2m from the Conservation
Parkland boundary, with minor intrusions
permitted where footings do not adversely
impact on vegetation within the Conservation
Parkland to the reasonable satisfaction of the
Manager Land Use.

 

Built to Boundary Walls and__ Side
Setbacks

All lots containing built to boundary walls
shall provide a minimum side setback of 3m
measured for the building fagade to one of
the boundaries to ensure open space is
maintained between each of the dwelling
units.

Where no built to boundary walls are
identified by the building envelope on the lot,
buildings shall be setback a minimum of
4.5m from one side boundary.

The maximum length of Built to Boundary
walls is 8.0m, built within a maximum of 15m
from the front boundary alignment.

The maximum height of a built to boundary
wall is 3.5m and is to be constructed with
materials consistent with the remainder of
the dwelling.

Built to boundary walls are permitted on lots
less than 600m2 and all lots which abut
conservation parklands.

Compliant

A 1.5m side setback is provided to the
southern boundary measured from the
boundary to the building line, while a 3.4m
side setback is provided to the northern
boundary measured from the boundary to the
building wall.

 

 

Building Height

Except for Lots 1-5, 9, 10 & 13 that shall not
exceed 1 storey, the maximum building
height of 2 storeys and 8 metres applies, in
accordance with the Schedule to the
Planning Scheme for Noosa Shire shall

apply.

Estate Sales Office:

Any Estate Sales Office or Display Home
must comply with the provisions of section
5.14 of the Transitional Planning Scheme for
Noosa Shire.

Community Use Facilities:

Community Use Facilities are to be located
in accordance with this Plan of Development
and are to be developed generally in
accordance with the Community Centre
proposal plans prepared by AV Jennings
Plans SKO1A (Feb 11), SKO2 (Feb 11) &
SKO3 (Feb 11).

 

Compliant
The proposed dwelling is configured over one

(1) storey and is below the 8m height limit.

 

Page 15 of 26

 

Page 16

Allotment 85

   

aan
Key Requirements
Group Housing Development Precinct
Private Open Space

Entry Lots 901/902:
e No Dwellings or Structures other
than depicted in the approval

landscape plan are to be erected or
otherwise installed on these lots.

e Maintenance agreement to be
included in all bodies corporate to
ensure ongoing maintenance of
entrance features.

Group Housing Lots 94 & 99:
« Dwelling units within lot 94 & 99,
adjacent fo the entry road, are to be
set back a minimum of 6 metres.

Compliant
No dwellings or Structures are proposed to be

erected on lots 901, 902, 94 & 99 as part of
this proposal.

 

General

General requirements for all group Housing
Development Precinct Residential Lots:

All buildings shall be screened where
practical to prevent the ingress of
mosquitoes and smaller biting midges.

Compliant
All proposed buildings will be screened where
practical.

 

Site Cover
The maximum site cover for any lot shall not
exceed:
e 50% for ground floor; and
e 40% for First Floor to achieve a
steeping of buildings.

Compliant

The proposal is configured over one (1) storey
and comprises a total site cover of 52%,
however, a 49% site cover is achieved
pursuant to the definition of site cover, which
allows for the sala to be measured 600mm in
from the perimeter of the roof.

 

Front Setbacks

Alllots shall have a minimum front setback of
3 metres, with garages setback a minimum
of 4.5m, with minor intrusions permitted of
eaves, covered entrances and the like.
Where a lesser setback than 5.4m _ is
proposed to garages:

e Provision shall be given for visitor
parking on the driveway with a
minimum length of 5.4 metres,
measured form the garage and a 3.0
metre separation from the back of
kerb to the rear of a parked vehicle
maintained.

e The sightline requirements to the
footpath shall be maintained in
accordance with AS2890.1-2004, for
vehicles parked on the proposed
driveways.

e Front and side setbacks are to be
measured from the facade (face of
building) to the boundary.

 

Where the boundary alignment is non linear

 

Compliant

The proposed dwelling is in accordance with
requirements and includes a minimum 4m
setback measured from the boundary to the
front building line and a 5.5m setback from
the footpath to the garage. We confirm that
the proposed garage is setback behind with
the main dwelling facade.

 

Page 16 of 26

 

Page 17

 

or irregular, for example corner blocks or cul
de sac, the setback shall be calculated as an
average distance along the length of the
facade (face of the building) or garage
alignment, which ever applies.

Garages shall be setback in line with the
main dwelling facade or behind the main
dwelling facade.

 

Secondary Frontage (corner allotments)
The minimum setback from the secondary
street frontage shall be 3.0m. Windows,
balconies, verandas and screening devices
are to be incorporated into elevations facing
street frontages to articulate building form.
Laundries and clothes-drying facilities are
not to be located along the primary or
secondary street frontage, unless suitable
screening is provided.

Compliant
The proposal is not for a corner allotment.

Notwithstanding this, the proposal includes
perimeter fencing and landscaped treatments.
Further, the proposal contains high quality
building design and materials to articulate the
building form, including the incorporation of
screening devices such as aluminium louvers
on the building facade, refer to Proposal
Plans prepared by AV Jennings located at
Appendix A.

 

Rear Setbacks

The minimum rear building setback shall be
2metres, with minor intrusions permitted for
eaves and the like.

Buildings shall be setback a minimum of 6m
from the Conservation Parkland boundary,
with minor intrusions permitted of eaves and
the like.

Swimming pools, pergolas, low decks and
garden structures shall be setback a
mininum of 2m from the Conservation
Parkland boundary, with minor intrusions
permitted where footings do not adversely
impact on vegetation within the Conservation
Parkland to the reasonable satisfaction of the
Manager Land Use.

Compliant

The proposal includes a 3m_ setback
measured from the rear property boundary to
the building line.

The proposal is not sited adjacent to or abuts
the Conservation Parkland boundary.

 

 

Built_ to Boundary Walls _and__ Side
Setbacks

All lots containing built to boundary walls
shall provide a minimum side setback of 3m
measured for the building fagade to one of
the boundaries to ensure open space is
maintained between each of the dwelling

units.

Where no built to boundary walls are
identified by the building envelope on the lot,
buildings shall be setback a minimum of
1.5m from one side boundary.

The maximum length of Built to Boundary
walls is 8.0m, built within a maximum of 15m
from the front boundary alignment.

The maximum height of a built to boundary
wall is 3.5m and is to be constructed with
materials consistent with the remainder of
the dwelling.

 

Compliant

A 3.4m side setback is provided to the
northern boundary measured from the
boundary to the Sala, while a 1.5m side
setback is provided to the southern boundary
measured from the boundary to the building
wall.

 

Page 17 of 26

 

Page 18

 

Built to boundary walls are permitted on lots
less than 600m2 and all lots which abut
conservation parklands.

 

Building Height

Except for Lots 1-5, 9, 10 & 13 that shall not
exceed 1 storey, the maximum _ building
height of 2 storeys and 8 metres applies, in
accordance with the Schedule to the
Planning Scheme for Noosa Shire shall

apply.

Estate Sales Office:

Any Estate Sales Office or Display Home
Must comply with the provisions of section
5.14 of the Transitional Planning Scheme for
Noosa Shire.

Community Use Facilities:

Community Use Facilities are to be located
in accordance with this Plan of Development
and are to be developed generally in
accordance with the Community Centre
proposal plans prepared by AV Jennings
Plans SKO1A (Feb 11), SKO2 (Feb 11) &
SKO3 (Feb 11).

 

 

Compliant
The proposed dwelling is configured over one
(1) storey and is below the 8m height limit.

 

 

Allotment 86

Key Requirements
Group Housing Development Precinct

Private Open Space
Entry Lots 901/902:

e No Dwellings or Structures other
than depicted in the approval
landscape plan are to be erected or
otherwise installed on these lots.

e« Maintenance agreement to be
included in all bodies corporate to
ensure ongoing maintenance of
entrance features.

Group Housing Lots 94 & 99:
e Dwelling units within jot 94 & 99,
adjacent to the entry road, are to be
set back a minimum of 6 metres.

Compliant
No dwellings or Structures are proposed to be

erected on lots 901, 902, 94 & 99 as part of
this proposal.

 

General

General requirements for all group Housing
Development Precinct Residential Lots:

All buildings shall be screened where
practical io prevent the ingress of
mosquitoes and smaller biting midges.

Compliant
All proposed buildings will be screened where
practical.

 

Site Cover
The maximum site cover for any lot shall not
exceed:

e 50% for ground floor; and

e 40% for First Floor to achieve a

 

 

Compliant

The proposal is configured over one (1) storey
and comprises a total site cover of 49.6%,
less than the prescribed 50% site cover for
the ground floor.

 

 

Page 18 of 26

Page 19

 

steeping of buildings.

 

Front Setbacks

All lots shall have a minimum front setback of
3 metres, with garages setback a minimum
of 4.5m, with minor intrusions permitted of
eaves, covered entrances and the like.
Where a lesser setback than 5.4m is
proposed to garages:

e Provision shall be given for visitor
parking on the driveway with a
minimum length of 5.4 metres,
measured form the garage and a 3.0
metre separation from the back of
kerb to the rear of a parked vehicle
maintained.

e The sightline requirements to the
footpath shall be maintained in
accordance with AS2890.1-2004, for
vehicles parked on the proposed
driveways.

e Front and side setbacks are to be
measured from the facade (face of
building) to the boundary.

Where the boundary alignment is non linear
or irregular, for example corner blocks or cul
de sac, the setback shall be calculated as an
average distance along the length of the
facade (face of the building) or garage
alignment, which ever applies.

Garages shall be setback in line with the
main dwelling facade or behind the main
dwelling facade.

Compliant

The proposed dwelling is in accordance with
requirements and includes a minimum 4m
setback measured from the footpath to the
front building line, and a 5.5m_ setback
measured from the boundary to the garage.
We confirm that the proposed garage is
setback behind with the main dwelling facade.

 

Secondary Frontage (corner allotments)
The minimum setback from the secondary
street frontage shall be 3.0m. Windows,
balconies, verandas and screening devices
are to be incorporated into elevations facing
street frontages to articulate building form.
Laundries and clothes-drying facilities are
not to be located along the primary or
secondary street frontage, unless suitable
screening is provided.

Compliant
The proposal is not for a corner allotment.

Notwithstanding this, the proposal includes
perimeter fencing and landscaped treatments.
Further, the proposal contains high quality
building design and materials to articulate the
building form, including the incorporation of
screening devices such as aluminium louvers
on the building facade, refer to Proposal
Plans prepared by AV Jennings located at
Appendix A.

 

 

Rear Setbacks

The minimum rear building setback shall be
2metres, with minor intrusions permitted for
eaves and the like.

Buildings shall be setback a minimum of 6m
from the Conservation Parkland boundary,
with minor intrusions permitted of eaves and
the like.

Swimming pools, pergolas, low decks and
garden structures shall be setback a
minimum of 2m from the Conservation
Parkland boundary, with minor intrusions

 

Compliant
The proposal includes a 3.4m_ setback

measured from the rear property boundary to
the building line.

The proposal is not sited adjacent to or abuts
the Conservation Parkland boundary.

 

Page 19 of 26

 

Page 20

 

permitted where footings do not adversely
impact on vegetation within the Conservation
Parkland to the reasonable satisfaction of the
Manager Land Use.

 

Built to Boundary Walls__and__ Side
Setbacks

All lots containing built to boundary walls
shall provide a minimum side setback of 3m
measured for the building fagade to one of
the boundaries to ensure open space is
maintained between each of the dwelling
units.

Where no built to boundary walls are
identified by the building envelope on the lot,

buildings shall be setback a minimum of |

1.5m from one side boundary.

The maximum jength of Built to Boundary
walls is 8.0m, built within a maximum of 15m
from the front boundary alignment.

The maximum height of a built to boundary
wall is 3.5m and is to be constructed with
materials consistent with the remainder of
the dwelling.

Built to boundary walls are permitted on lots
less than 600m2 and all lots which abut
conservation parklands.

Acceptable Solution

It is recognised that built to boundary walls
are permitted on lots less than 600m2, and is
therefore applicable to this lot.

The garage is built to boundary, whilst a 2.6m
side setback is provided to the balance of the
southern boundary and a 4.9m side setback is
provided to the northern boundary.

It is noted however that the roof of the sala
extends 1.6m into the northern side setback.
By definition the sala is permitted to encroach
up to 600mm into the side setback. It is our
view that the design as submitted achieves an
acceptable amenity outcome.

Additionally, because each of the houses are
clustered together for approval of the designs
as submitted, all purchasers of lots will be
making their purchaser decision in full
knowledge of the approved setbacks of the
adjoining lots.

Further, the maximum length of the garage
wall built to the boundary is 6m within a
maximum of 15m from the front boundary
alignment. The maximum height of the built to
boundary wall is 2.7m.

 

 

Building Height
Except for Lots 1-5, 9, 10 & 13 that shall not

exceed 1 storey, the maximum building
height of 2 storeys and 8 metres applies, in
accordance with the Schedule to the
Planning Scheme for Noosa Shire shall
apply.

Estate Sales Office:

Any Estate Sales Office or Display Home
must comply with the provisions of section
5.14 of the Transitional Planning Scheme for
Noosa Shire.

Community Use Facilities:

Community Use Facilities are to be located
in accordance with this Plan of Development
and are to be developed generally in
accordance with the Community Centre
proposal plans prepared by AV Jennings
Plans SKO1A (Feb 11), SKO2 (Feb 11) &
SKO3 (Feb 11).

 

Compliant
The proposed dwelling is configured over one

(1) storey and is below the 8m height limit.

 

Page 20 of 26

 

Page 21

Allotment 87

     

Key Requirements
Group Housing Development Precinct
Private Open Space

Entry Lots 907/902:
e No Dwellings or Structures other
than depicted in the approval

landscape plan are to be erected or
otherwise installed on these lots.

e Maintenance agreement to be
included in all bodies corporate to
ensure ongoing maintenance of
entrance features.

Group Housing Lots 94 & 99:
e Dwelling units within lot 94 & 99,
adjacent to the entry road, are to be
set back a minimum of 6 metres.

Compliant
No dwellings or Structures are proposed to be
erected on lots 901, 902, 94 & 99 as part of
this proposal.

 

General

General requirements for all group Housing
Development Precinct Residential Lots:

All buildings shall be screened where
practical to prevent the ingress of
mosquitoes and smaller biting midges.

Compliant
All proposed buildings will be screened where
practical.

 

Site Cover
The maximum site cover for any lot shall not
exceed:
e 50% for ground floor; and
e 40% for First Floor to achieve a
steeping of buildings.

Compliant

The proposal is configured over one (1) storey
and comprises a total site cover of 49.5%,
less than the prescribed 50% site cover for
the ground floor.

 

Front Setbacks

Alllots shall have a minimum front setback of
3 metres, with garages setback a minimum
of 4.5m, with minor intrusions permitted of
eaves, covered entrances and the like.
Where a lesser setback than 5.4m is
proposed to garages:

e Provision shall be given for visitor
parking on the driveway with a
minimum length of 5.4 metres,
measured form the garage and a 3.0
metre separation from the back of
kerb to the rear of a parked vehicle
maintained.

e The sightline requirements to the
footpath shall be maintained in
accordance with AS2890.1-2004, for
vehicles parked on the proposed
driveways.

e Front and side setbacks are to be
measured from the facade (face of
building) to the boundary.

Where the boundary alignment is non linear
or irregular, for example corner blocks or cul

 

 

Compliant

The proposed dwelling is in accordance with
requirements and includes a minimum 3m
setback measured from the footpath to the
front building line, and a 4.5m setback
measured from the boundary to the garage.
In addition, the provision of a cross over
measured approximately 7.2m from the
boundary to the street frontage enables visitor
parking on the driveway. We confirm that
the proposed garage is setback behind with
the main dwelling facade.

 

Page 21 of 26

 

Page 22

 

de sac, the setback shall be calculated as an
average distance along the length of the
facade (face of the building) or garage
alignment, which ever applies.

Garages shall be setback in line with the
main dwelling facade or behind the main
dwelling facade.

 

Secondary Frontage (corner allotments)
The minimum setback from the secondary
street frontage shall be 3.0m. Windows,
balconies, verandas and screening devices
are to be incorporated into elevations facing
street frontages to articulate building form.
Laundries and clothes-drying facilities are
not to be located along the primary or
secondary street frontage, unless suitable
screening is provided.

Compliant
The proposal is not for a corner allotment.

Notwithstanding this, the proposal includes
perimeter fencing and landscaped treatments.
Further, the proposal contains high quality
building design and materials to articulate the
building form, including the incorporation of
screening devices such as aluminium louvers
on the building facade, refer to Proposal
Plans prepared by AV Jennings located at
Appendix A.

 

Rear Setbacks

The minimum rear building setback shall be
2metres, with minor intrusions permitted for
eaves and the like.

Buildings shall be setback a minimum of 6m
from the Conservation Parkland boundary,
with minor intrusions permitted of eaves and
the like.

Swimming pools, pergolas, low decks and
garden structures shall be setback a
minimum of 2m from the Conservation
Parkland boundary, with minor intrusions
permitted where footings do not adversely
impact on vegetation within the Conservation
Parkland to the reasonable satisfaction of the
Manager Land Use.

Compliant
The proposal includes a 4m_ setback

measured from the rear property boundary to
the building line.

The proposal is not sited adjacent to or abuts
the Conservation Parkland boundary.

 

 

Built to Boundary Walls _and__ Side
Setbacks

All lots containing built to boundary walls
shall provide a minimum side setback of 3m
measured for the building fagade to one of
the boundaries to ensure open space is
maintained between each of the dwelling

units.

Where no built to boundary walls are
identified by the building envelope on the lot,
buildings shall be setback a minimum of
1.5m from one side boundary.

The maximum length of Built to Boundary
walls is 8.0m, built within a maximum of 15m
from the front boundary alignment.

The maximum height of a built to boundary
wall is 3.5m and is to be constructed with
materials consistent with the remainder of
the dwelling.

Built to boundary walls are permitted on lots

 

Acceptable Solution

It is recognised that built to boundary walls
are permitted on lots less than 600m2, and is
therefore applicable to this lot.

The garage is built to boundary, whilst a 2.6m
side setback is provided to the balance of the
southern boundary and a 4.9m side setback is
provided to the northern boundary.

It is noted however that the roof of the sala
extends 1.6m into the northern side setback.
By definition the sala is permitted to encroach
up to 600mm into the side setback. It is our
view that the design as submitted achieves an
acceptable amenity outcome.

Additionally, because each of the houses are
clustered together for approval of the designs
as submitted, all purchasers of lots will be
making their purchaser decision in full
knowledge of the approved setbacks of the
adjoining lots.

 

Page 22 of 26

 

Page 23

 

less than 600m2 and all lots which abut
conservation parklands.

Further, the maximum length of the garage
wall built to the boundary is 6m within a
maximum of 15m from the front boundary
alignment. The maximum height of the built to
boundary wall is 2.7m.

 

Building Height

Except for Lots 1-5, 9, 10 & 13 that shall not
exceed 1 storey, the maximum building
height of 2 storeys and 8 metres applies, in
accordance with the Schedule to the
Planning Scheme for Noosa Shire shall

apply.

Estate Sales Office:

Any Estate Sales Office or Display Home
must comply with the provisions of section
5.14 of the Transitional Planning Scheme for
Noosa Shire.

Community Use Facilities:

Community Use Facilities are to be located
in accordance with this Plan of Development
and are to be developed generally in
accordance with the Community Centre
proposal plans prepared by AV Jennings
Plans SKO1A (Feb 11), SKO2 (Feb 11) &
SKO3 (Feb 11).

 

 

Compliant
The proposed dwelling is configured over one
(1) storey and is below the 8m height limit.

 

 

Allotment 88

Key Requirements
Group Housing Development Precinct

Private Open Space

Entry Lots 901/902:
e No Dwellings or Structures other
than depicted in the approval

landscape plan are to be erected or
otherwise installed on these lots.

e Maintenance agreement to be
included in all bodies corporate to
ensure ongoing maintenance of
entrance features.

Group Housing Lots 94 & 99:
e Dwelling units within lot 94 & 99,
adjacent to the entry road, are to be
set back a minimum of 6 metres.

Compliant

No dwellings or Structures are proposed to be
erected on lots 901, 902, 94 & 99 as part of
this proposal.

 

General

General requirements for all group Housing
Development Precinct Residential Lots:

All buildings shall be screened where
practical to prevent the ingress of
mosquitoes and smaller biting midges.

Compliant
All proposed buildings will be screened where
practical.

 

Site Cover
The maximum site cover for any lot shall not
exceed:

 

 

Compliant
The proposal is configured over one (1) storey
and comprises a total site cover of 49.5%,

 

 

Page 23 of 26

Page 24

 

e 50% for ground floor; and
e 40% for First Floor to achieve a
steeping of buildings.

less than the prescribed 50% site cover for
the ground floor.

 

Front Setbacks

All lots shall have a minimum front setback of
3 metres, with garages setback a minimum
of 4.5m, with minor intrusions permitted of
eaves, covered entrances and the like.
Where a lesser setback than 5.4m _ is
proposed to garages:

e Provision shail be given for visitor
parking on the driveway with a
minimum length of 5.4 metres,
measured form the garage and a 3.0
metre separation from the back of
kerb to the rear of a parked vehicle
maintained.

e The sightline requirements to the
footpath shall be maintained in
accordance with AS2890.1-2004, for
vehicles parked on the proposed
driveways.

e Front and side setbacks are to be
measured from the facade (face of
building) to the boundary.

Where the boundary alignment is non linear
or irregular, for example corner blocks or cul
de sac, the setback shall be calculated as an
average distance along the length of the
facade (face of the building) or garage
alignment, which ever applies.

Garages shall be setback in line with the
main dwelling facade or behind the main
dwelling facade.

Compliant
The proposed dwelling is in accordance with

requirements and includes a minimum 3m
setback measured from the footpath to the
front building line, and a 4.5m _ setback
measured from the boundary to the garage.
In addition, the provision of a cross over
measured approximately 5.2m from the
boundary to the street frontage enables visitor
parking on the driveway. We confirm that
the proposed garage is setback behind with
the main dwelling facade.

 

Secondary Frontage (corner allotments)
The minimum setback from the secondary
street frontage shal! be 3.0m. Windows,
balconies, verandas and screening devices
are to be incorporated into elevations facing
street frontages to articulate building form.
Laundries and clothes-drying facilities are
not to be located along the primary or
secondary street frontage, unless suitable
screening is provided.

Compliant
The proposal is not for a corner allotment.

Notwithstanding this, the proposal includes
perimeter fencing and landscaped treatments.
Further, the proposal contains high quality
building design and materials to articulate the
building form, including the incorporation of
screening devices such as aluminium louvers
on the building facade, refer to Proposal
Plans prepared by AV Jennings located at
Appendix A.

 

 

Rear Setbacks

The minimum rear building setback shall be
2metres, with minor intrusions permitted for
eaves and the like.

Buildings shall be setback a minimum of 6m
from the Conservation Parkland boundary,
with minor intrusions permitted of eaves and
the like.

Swimming pools, pergolas, low decks and
garden structures shall be setback a
minimum of 2m from the Conservation

 

Compliant

The proposal includes a 3.3m_ setback
measured from the rear property boundary to
the building line.

The proposal is not sited adjacent to or abuts
the Conservation Parkland boundary.

 

Page 24 of 26

 

Page 25

 

Parkland boundary, with minor intrusions
permitted where footings do not adversely
impact on vegetation within the Conservation
Parkland to the reasonable satisfaction of the
Manager Land Use.

 

Built to Boundary Walls and _ Side
Setbacks

All lots containing built to boundary walls
shall provide a minimum side setback of 3m
measured for the building fagade to one of
the boundaries to ensure open space is
maintained between each of the dwelling

units.

Where no built to boundary walls are
identified by the building envelope on the lot,
buildings shall be setback a minimum of
1.5m from one side boundary.

The maximum length of Built to Boundary
walls is 8.0m, built within a maximum of 15m
from the front boundary alignment.

The maximum height of a built to boundary
wall is 3.5m and is to be constructed with
materials consistent with the remainder of
the dwelling.

Built to boundary walls are permitted on lots
less than 600m2 and all lots which abut
conservation parklands.

Acceptable Solution

It is recognised that built to boundary walls
are permitted on lots less than 600m2, and is
therefore applicable to this lot.

The garage is built to boundary, whilst a 2.6m
side setback is provided to the balance of the
southern boundary and a 4.9m side setback is
provided to the northern boundary.

It is noted however that the roof of the sala
extends 1.6m into the northern side setback.
By definition the sala is permitted to encroach
up to 600mm into the side setback. It is our
view that the design as submitted achieves an
acceptable amenity outcome.

Additionally, because each of the houses are
clustered together for approval of the designs
as submitted, all purchasers of lots will be
making their purchaser decision in full
knowledge of the approved setbacks of the
adjoining lots.

Further, the maximum length of the garage
wall built to the boundary is 6m within a
maximum of 15m from the front boundary
alignment. The maximum height of the built
to boundary wall is 2.7m.

 

 

Building Height
Except for Lots 1-5, 9, 10 & 13 that shall not

exceed 1 storey, the maximum building
height of 2 storeys and 8 metres applies, in
accordance with the Schedule to the
Planning Scheme for Noosa Shire shall

apply.

Estate Sales Office:

Any Estate Sales Office or Display Home
must comply with the provisions of section
§.14 of the Transitional Planning Scheme for
Noosa Shire.

Community Use Facilities:

Community Use Facilities are to be located
in accordance with this Plan of Development
and are to be developed generally in
accordance with the Community Centre
proposal plans prepared by AV Jennings
Plans SKO1A (Feb 11), SKO2 (Feb 11) &
SKO3 (Feb 11).

 

Compliant
The proposed dwelling is configured over one
(1) storey and is below the 8m height limit.

 

Page 25 of 26

 

Page 26

Based on the above, the proposed Detached Houses comply with the relevant Key
Development Requirements as indicated on the approved Elysium Master Plan document.

3. CONCLUSION

Based on the above assessment, the application complies with the relevant provisions of the
approved Elysium Masterplan. We trust that the information submitted is sufficient to enable

prompt and favourable assessment.

Should you require any further information or wish to discuss any aspect of the proposal,
please do not hesitate to contact our office.

Yours faithfully

RPS

McA

Mark Farrell
General Manager

Enc Proposal Plans
Cheque
IDAS Forms
Email correspondence dated 24" April 2013
Lot Calculations Plan

Page 26 of 26

Used in these records

About this file

File size
1.3 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Town Planning Report.pdf · 1.3 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.