Council archive · source document
Town Planning Report · MCU13/0102
Sunshine Coast Office | Innovation Parkway, Birtinya, PO Box 149,Wurtulla QLD Australia 4575 +6] 7 5436 7888 F +61 7 5493 6630 E [email protected] W rpsgroup.com.au Our Ref: PR114330-3.1001MF.Ip Date: 29"" May 2013 The Chief Executive Officer Sunshine Coast Regional Council Locked bag 72 SCMC QLD 4560 Dear Sir/ Madam RE: APPLICATION FOR MATERIAL CHANGE OF USE - NINE (9) DETACHED HOUSES, PROPOSED LOTS 41, 42, 57, 89, 90, 91, 92, & 93 SMOKE BUSH DRIVE, NOOSA HEADS, ELYSIUM NOOSA PTY LTD We act on behalf of the applicant AVJennings, in relation to the abovementioned Development Application. Enclosed for your receipt and assessment is the following application documentation:- IDAS Form 1 - Application Details; IDAS Form 5 — Material Change of Use Assessable Against a Planning Scheme; Proposal Plans prepared by AV Jennings; Cheque made payable to Sunshine Coast Regional Council in the sum of $2,277 being the mandatory application fees; Email correspondence dated 24 April 2013; and e Proposed Community Titles Subdivision Lot Calculations Plan, Plan No. 6994-26Q, dated 24-10-2004. Under Section 261(A) of the Sustainable Planning Act 2009, this application is properly made. This letter outlines the details of the proposal, and the proposal’s compliance with the Noosa Plan and the approved Master Plan for Elysium Noosa. PROPOSAL Details of the site and the proposal are summarised as follows: Street Address: Smoke Bush Drive, Noosa Real Property Description: Lot 503 on SP251598 & Lots 90-93 on SP251598 Proposal: Nine (9) Detached Houses, being located on Proposed Lots 58-61 and Lots 84- 88within the Elysium residential development. Land Area: Lot 58 -518m? Lot 59 - 522m? Lot 60 - 532m? Lot 61 — 585m? Lot 84 - 579m? Lot 85 — 570m? Lot 86 -— 562m? Lot 87 — 553m? Lot 88 — 553m? APONn> Oana Zoning: Detached Housing Precinct Previous Approvals: Material Change of Use Non-Urban to Special Residential for 196 Dwellings and Lot Reconfiguration Creation of 100 lots (inc 99 conventional lots and 6 group title lots) Ref: 23245 DA dated 29 April 2004 Development Permit Material Change of Use & Preliminary Reconfiguration of a Lot Ref: England | Wales | Scotland | Northern Ireland [ Ireland | Netherlands | USA | Australia Page 1 of 26 APS Austraia East Pty Ltd ABN 44 (40 292 762 A member of the RPS Group Plc
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 25 pages
Page 2
2003/220735 (23245 DA) dated 28 October 2005 Development Permit Reconfiguration of a Lot Approval Ref: 2005/170 dated 3 November 2005 Plan of Development ~ ‘Elysium Sunset Drive, Noosa Springs Road’ - Group housing development in accordance with Approved Plans 6994.53C.dwg Revision C (C23245 DA) Development Permit Material Change of Use (8 x Detached Houses) Ref: MCU12/0144 dated 5 November 2012 The proposal is for the establishment of nine (9) Detached Houses located within the Elysium tesidential development. The Detached Houses are to be located on the abovementioned proposed allotments with a single house located on each of these allotments. 1.1 Dwelling House Design Characteristics The details of the nine (9) Detached Houses are depicted in the Elevations and Floor Plans as attached to this report (refer Attachment 1). The Detached Houses are characterised by the following design features that provide the highest standards of quality and amenity: - Substantial areas of private open space; Internal courtyards, Extensive covered outdoor areas; High quality finishes; Open plan arrangements; and Careful attention paid to articulation on all elevations. In addition, careful consideration has been given to the ‘sustainability’ components, including the following: - e High level natural light; e Ventilation through louvered clerestories; e Most dwellings situated with a northerly aspect for summer and winter courtyard living; Sun screening with use of motorised and stationary sun blades; Pivoting sun blades that adjust for wind control; Incorporation of solar panels and solar hot water services; Extensive use of endemic subtropical landscaping: and Cross-ventilation as a fundamental consideration in all designs. 2. COMPLIANCE WITH PLANNING SCHEME AND EARLIER APPROVALS Pursuant to The Noosa Pian, the site is included within the Noosa Heads Locality Plan and located in the Detached Housing Precinct. Further, the site is subject to the associated Plan of Development for Elysium Noosa, under Group Housing Development in accordance with Approved Plans 6994.53C.dwg Revision C (Council Reference C23245 DA). As specified in the Supplementary Table of Development Plan on the Plan of Development (where the development parameters are predicted), the proposal will be ‘Development to follow a Code Assessment Process’. For the purposes of this assessment, ‘setback’ and ‘site cover’ is defined in accordance with ‘Part 2 — Interpretation and Dictionary’ of The Noosa Plan. Page 2 of 26
Page 3
setback means the minimum distance from any /ot boundary to a building or structure, excluding eaves, roof overhangs and awnings provided they encroach no more than 600mm into the setback distance. site cover means the proportion of a site covered by all buildings and structures shown as a percentage. For enclosed spaces this includes the area within the outside wall and for unenclosed spaces this includes the area measured along a line 600mm in from the perimeter of the roof. Site cover includes garages and other roofed outbuildings, but does not include landscape structures such as in-ground pools and decks. It is noted that the site cover stated on the Proposal Plans includes the full roof area of the salas without making any allowance for the permitted 600mm intrusion and hence they are overstated. Please note, the Plan of Development notates that all dimensions and areas are approximate only, and are subject to survey and Council approval, as such, the Proposal Plans have been prepared in respect of the most recent Lot Caiculations Plan which accurately represents all lot areas. Further, the Lot Calculation Plan identifies a 1-2m? increase in lot area to lots 84-88, in comparison to the Plan of Development, which is considered negligible in the context of calculating site cover. 2.1 Compliance with Elysium Master Plan (Key Development Requirements) The approved Plan of Development for Elysium Noosa provides key development requirements for a range of uses. The key development requirements table on the approved Plan of Development indicates the general requirements for all Group Housing Development precinct residential lots. The provisions of the Key Development Requirements for Precincts are considered below: Allotment 58 Key Requirements Group Housing Development Precinct Private Open Space Entry Lots 901/902: e No Dwellings or Structures other than depicted in the approval landscape plan are to be erected or otherwise installed on these lots. e Maintenance agreement to be included in all bodies corporate to ensure ongoing maintenance of entrance features. Group Housing Lots 94 & 99: e Dwelling units within lot 94 & 99, adjacent to the entry road, are to be set back a minimum of 6 metres. Compliant No dwellings or Structures are proposed to be erected on lots 901, 902, 94 & 99 as part of this proposal. General General requirements for all group Housing Development Precinct Residential Lots: All buildings shall be screened where practical to prevent the ingress of mosquitoes and smaller biting midges. Compliant Screening requirements to be conditioned. Site Cover The maximum site cover for any lot shall not exceed: e 50% for ground floor; and Compliant The proposal is configured over one (1) storey and comprises a total site cover of 46.7%, less than the prescribed 50% site cover for Page 3 of 26
Page 4
e 40% for First Floor to achieve a steeping of buildings. the ground floor. Front Setbacks Alllots shall have a minimum front setback of 3 metres, with garages setback a minimum of 4.5m, with minor intrusions permitted of eaves, covered entrances and the like. Where a lesser setback than 5.4m is proposed to garages: e Provision shall be given for visitor parking on the driveway with a minimum length of 5.4 metres, measured form the garage and a 3.0 metre separation from the back of kerb to the rear of a parked vehicle maintained. e The sightline requirements to the footpath shall be maintained in accordance with AS2890.1-2004, for vehicles parked on the proposed driveways. e Front and side setbacks are to be measured from the facade (face of building) to the boundary. Where the boundary alignment is non linear or irregular, for example corner blocks or cul de sac, the setback shall be calculated as an average distance along the length of the facade (face of the building) or garage alignment, which ever applies. Garages shall be setback in line with the main dwelling facade or behind the main dwelling facade. Compliant The proposed dwelling is in accordance with requirements and includes a minimum 5m setback measured from the boundary to the front building line and a 4.5m_ setback measured from the boundary to the garage. Further, the provision of a cross over measured approximately 5m from the boundary to the street frontage enables visitor parking on the driveway. We confirm that the proposed garage is setback behind with the main dwelling facade. Secondary Frontage (corner allotments) The minimum setback from the secondary street frontage shall be 3.0m. Windows, balconies, verandas and screening devices are to be incorporated into elevations facing street frontages to articulate building form. Laundries and clothes-drying facilities are not to be located along the primary or secondary street frontage, unless suitable screening is provided. Compliant The proposal is not for a corner allotment. Notwithstanding, the proposal includes perimeter fencing and landscaped treatments. Further, the proposal contains high quality building design and materials to articulate the building form, including the incorporation of screening devices such as aluminium louvers on the building facade, refer to Proposal Plans prepared by AV Jennings located at Appendix A. Rear Setbacks The minimum rear building setback shall be 2metres, with minor intrusions permitted for eaves and the like. Buildings shall be setback a minimum of 6m from the Conservation Parkland boundary, with minor intrusions permitted of eaves and the like. Swimming pools, pergolas, low decks and garden structures shall be setback a Minimum of 2m from the Conservation Compliant The proposal includes a 3m_ setback measured from the rear property boundary to the building line. The proposal is not sited adjacent to or abuts the Conservation Parkland boundary. Page 4 of 26
Page 5
Parkland boundary, with minor intrusions permitted where footings do not adversely impact on vegetation within the Conservation Parkland to the reasonable satisfaction of the Manager Land Use. Built to Boundary Walls_and_ Side Setbacks All lots containing built to boundary walls shall provide a minimum side setback of 3m measured for the building fagade to one of the boundaries to ensure open space is maintained between each of the dwelling units. Where no built to boundary walls are identified by the building envelope on the lot, buildings shall be setback a minimum of 1.5m from one side boundary. The maximum length of Built to Boundary walls is 8.0m, built within a maximum of 15m from the front boundary alignment. The maximum height of a built to boundary wall is 3.5m and is to be constructed with materials consistent with the remainder of the dwelling. Built to boundary walls are permitted on lots less than 600m2 and all lots which abut conservation parklands. Acceptable Solution It is recognised that built to boundary walls are permitted on lots less than 600m2, and is therefore applicable to this lot. The garage is built to boundary, whilst a 2.6m side setback is provided to the balance of the southern boundary and a 5.2m side setback is provided to the northern boundary. It is noted however that the roof of the sala extends 1.6m into the northern side setback. By definition the sala is permitted to encroach up to 600mm into the side setback. It is our view that the design as submitted achieves an acceptable amenity outcome. Additionally, because each of the houses are clustered together for approval of the designs as submitted, all purchasers of lots will be making their purchaser decision in full knowledge of the approved setbacks of the adjoining lots. The maximum length of the garage wall built to the boundary is 6m within a maximum of 15m from the front boundary alignment. The maximum height of the built to boundary wall is 2.7m. Building Height Except for Lots 1-5, 9, 10 & 13 that shall not exceed 1 storey, the maximum _ building height of 2 storeys and 8 metres applies, in accordance with the Schedule to the Planning Scheme for Noosa Shire shall apply. Estate Sales Office: Any Estate Sales Office or Display Home must comply with the provisions of section 5.14 of the Transitional Planning Scheme for Noosa Shire. Community Use Facilities: Community Use Facilities are to be located in accordance with this Plan of Development and are to be developed generally in accordance with the Community Centre proposal plans prepared by AV Jennings Plans SKO1A (Feb 11), SKO2 (Feb 11) & SKO3 (Feb 11). Compliant The proposed dwelling is configured over one (1) storey and is below the 8m height limit. Page 5 of 26
Page 6
Allotment §9 Key Requirements Group Housing Development Precinct Private Open Space Entry Lots 901/902: e No Dwellings or Structures other than depicted in the approval landscape plan are to be erected or otherwise installed on these lots. « Maintenance agreement to be included in all bodies corporate to ensure ongoing maintenance of entrance features. Group Housing Lots 94 & 99: e Dwelling units within lot 94 & 99, adjacent to the entry road, are to be set back a minimum of 6 metres. Compliant No dwellings or Structures are proposed to be erected on lots 901, 902, 94 & 99 as part of this proposal. General General requirements for all group Housing Development Precinct Residential Lots: All buildings shall be screened where practical to prevent the ingress of mosquitoes and smaller biting midges. Compliant All proposed buildings will be screened where practical. Site Cover The maximum site cover for any lot shall not exceed: e« 50% for ground floor; and e 40% for First Floor to achieve a steeping of buildings. Compliant The proposal is configured over one (1) storey and comprises a total site cover of 46.4%, less than the prescribed 50% site cover for the ground floor. Eront Setbacks Alllots shall have a minimum front setback of 3 metres, with garages setback a minimum of 4.5m, with minor intrusions permitted of eaves, covered entrances and the like. Where a lesser setback than 5.4m _ is proposed to garages: e Provision shall be given for visitor parking on the driveway with a minimum length of 5.4 metres, measured form the garage and a 3.0 metre separation from the back of kerb to the rear of a parked vehicle maintained. e The sightline requirements to the footpath shall be maintained in accordance with AS2890.1-2004, for vehicles parked on the proposed driveways. e Front and side setbacks are to be Measured from the facade (face of Compliant The proposed dwelling is in accordance with requirements and includes a minimum 3m setback measured from the boundary to the front building line and a 4.5m _ setback measured from the boundary to the garage. Further, the provision of a cross over measured approximately 5m from the boundary to the street frontage enables visitor parking on the driveway. We confirm that the proposed garage is setback behind with the main dwelling facade. Page 6 of 26
Page 7
building) to the boundary. Where the boundary alignment is non linear or irregular, for example corner blocks or cul de sac, the setback shall be calculated as an average distance along the length of the facade (face of the building) or garage alignment, which ever applies. Garages shall be setback in line with the main dwelling facade or behind the main dwelling facade. Secondary Frontage (corner allotments) The minimum setback from the secondary street frontage shall be 3.0m. Windows, balconies, verandas and screening devices are to be incorporated into elevations facing street frontages to articulate building form. Laundries and clothes-drying facilities are not to be located along the primary or secondary street frontage, unless suitable screening is provided. Compliant The proposal is not for a corner allotment. Notwithstanding this, the proposal includes perimeter fencing and landscaped treatments. Further, the proposal contains high quality building design and materials to articulate the building form, including the incorporation of screening devices such as aluminium louvers on the building facade, refer to Proposal Plans prepared by AV Jennings located at Appendix A. Rear Setbacks The minimum rear building setback shall be 2metres, with minor intrusions permitted for eaves and the like. Buildings shall be setback a minimum of 6m from the Conservation Parkland boundary, with minor intrusions permitted of eaves and the like. Swimming pools, pergolas, low decks and garden structures shall be setback a minimum of 2m from the Conservation Parkland boundary, with minor intrusions permitted where footings do not adversely impact on vegetation within the Conservation Parkland to the reasonable satisfaction of the Manager Land Use. Compliant The proposal includes a 3m_ setback measured from the rear property boundary to the building line. The proposal is not sited adjacent to or abuts the Conservation Parkland boundary. Built to Boundary Walls and_ Side Setbacks All lots containing built to boundary walls shall provide a minimum side setback of 3m measured for the building fagade to one of the boundaries to ensure open space is maintained between each of the dwelling units. Where no built to boundary walls are identified by the building envelope on the lot, buildings shall be setback a minimum of 1.5m from one side boundary. The maximum length of Built to Boundary walls is 8.0m, built within a maximum of 15m from the front boundary alignment. The maximum height of a built to boundary wall is 3.5m_and is to be constructed with Acceptable Solution It is recognised that built to boundary walls are permitted on lots less than 600m2, and is therefore applicable to this lot. The garage is built to boundary, whilst a 2.6m side setback is provided to the balance of the southern boundary and a 6.4m side setback is provided to the northern boundary. It is noted however that the roof of the sala extends 100mm into the northern side setback. By definition the sala is permitted to encroach up to 600mm into the side setback. It is our view that the design as submitted achieves an acceptable amenity outcome. Additionally, because each of the houses are clustered together for approval of the designs Page 7 of 26
Page 8
materials consistent with the remainder of the dwelling. Built to boundary walls are permitted on lots less than 600m2 and all lots which abut conservation parklands. as submitted, all purchasers of lots will be making their purchaser decision in full knowledge of the approved setbacks of the adjoining lots. Further, the maximum length of the garage wall built to the boundary is 6m within a maximum of 15m from the front boundary alignment. The maximum height of the built to boundary wall is 2.7m. Building Height Except for Lots 1-5, 9, 10 & 13 that shall not exceed 1 storey, the maximum building height of 2 storeys and 8 metres applies, in accordance with the Schedule to the Planning Scheme for Noosa Shire shall apply. Estate Sales Office: Any Estate Sales Office or Display Home must comply with the provisions of section 5.14 of the Transitional Planning Scheme for Noosa Shire. Community Use Facilities: Community Use Facilities are to be located in accordance with this Plan of Development and are to be developed generally in accordance with the Community Centre proposal plans prepared by AV Jennings Plans SKO1A (Feb 11), SKO2 (Feb 11) & SKO3 (Feb 11). Compliant The proposed dwelling is configured over one (1) storey and is below the 8m height limit. Allotment 60 Key Requirements Group Housing Development Precinct Private Open Space Entry Lots 901/902: e No Dwellings or Structures other than depicted in the approval landscape plan are to be erected or otherwise installed on these lots. e Maintenance agreement to be included in all bodies corporate to ensure ongoing maintenance of entrance features. Group Housing Lots 94 & 99: e Dwelling units within lot 94 & 99, adjacent to the entry road, are to be set back a minimum of 6 metres. Compliant No dwellings or Structures are proposed to be erected on lots 901, 902, 94 & 99 as part of this proposal. General General requirements for all group Housing Development Precinct Residential Lots: All buildings shall be screened where practical to prevent the ingress of Compliant All proposed buildings will be screened where practical. Page 8 of 26
Page 9
mosquitoes and smaller biting midges. Site Cover The maximum site cover for any lot shall not exceed: e 50% for ground floor; and « 40% for First Floor to achieve a steeping of buildings. Compliant The proposal is configured over one (1) storey and comprises a total site cover of 45.5%, less than the prescribed 50% site cover for the ground floor. Front Setbacks Alllots shall have a minimum front setback of 3 metres, with garages setback a minimum of 4.5m, with minor intrusions permitted of eaves, covered entrances and the like. Where a lesser setback than 5.4m is proposed to garages: e Provision shall be given for visitor parking on the driveway with a minimum length of 5.4 metres, measured form the garage and a 3.0 metre separation from the back of kerb to the rear of a parked vehicle maintained. e The sightline requirements to the footpath shall be maintained in accordance with AS2890.1-2004, for vehicles parked on the proposed driveways. e Front and side setbacks are to be measured from the facade (face of building) to the boundary. Where the boundary alignment is non linear or irregular, for example corner blocks or cul de sac, the setback shall be calculated as an average distance along the length of the facade (face of the building) or garage alignment, which ever applies. Garages shall be setback in line with the main dwelling facade or behind the main dwelling facade. Compliant The proposed dwelling is in accordance with requirements and includes a minimum 3m setback measured from the boundary to the front building line, with the exception of a minor protrusion of the building wall. Further, a 5m setback is provided measured from the boundary to the garage. In addition, the provision of a cross over measured approximately 5m from the boundary to the street frontage enables visitor parking on the driveway. We confirm that the proposed garage is setback behind with the main dwelling facade. Secondary Frontage (corner allotments) The minimum setback from the secondary street frontage shall be 3.0m. Windows, balconies, verandas and screening devices are to be incorporated into elevations facing street frontages to articulate building form. Laundries and clothes-drying facilities are not to be located along the primary or secondary street frontage, unless suitable screening is provided. Compliant The proposal is not for a corner allotment. Notwithstanding this, the proposal includes perimeter fencing and landscaped treatments. Further, the proposal contains high quality building design and materials to articulate the building form, including the incorporation of screening devices such as aluminium louvers on the building facade, refer to Proposal Plans prepared by AV Jennings located at Appendix A. Rear Setbacks The minimum rear building setback shall be 2metres, with minor intrusions permitted for eaves and the like. Buildings shall be setback a minimum of 6m from the Conservation Parkland boundary, Compliant The proposal includes a 3m_ setback measured from the rear property boundary to the building line. The proposal is not sited adjacent to or abuts the Conservation Parkland boundary. Page 9 of 26
Page 10
with minor intrusions permitted of eaves and the like. Swimming pools, pergolas, low decks and garden structures shall be setback a minimum of 2m from the Conservation Parkland boundary, with minor intrusions permitted where footings do not adversely impact on vegetation within the Conservation Parkland to the reasonable satisfaction of the Manager Land Use. Built to Boundary Walls Setbacks All lots containing built to boundary walls shall provide a minimum side setback of 3m measured for the building fagade to one of the boundaries to ensure open space is maintained between each of the dwelling units. and_ Side Where no built to boundary walls are identified by the building envelope on the lot, buildings shall be setback a minimum of 1.5m from one side boundary. The maximum length of Built to Boundary walls is 8.0m, built within a maximum of 15m from the front boundary alignment. The maximum height of a built to boundary wall is 3.5m and is to be constructed with materials consistent with the remainder of the dwelling. Built to boundary walls are permitted on lots less than 600m2 and all lots which abut conservation parklands. Acceptable Solution It is recognised that built to boundary walls are permitted on lots less than 600m2, and is therefore applicable to this lot. The garage is built to boundary, whilst a 2.6m side setback is provided to the balance of the southern boundary and a 6.4m side setback is provided to the northern boundary. It is noted however that the roof of the sala extends 100mm into the northern side setback. By definition the sala is permitted to encroach up to 600mm into the side setback. It is our view that the design as submitted achieves an acceptable amenity outcome. Additionally, because each of the houses are clustered together for approval of the designs as submitted, all purchasers of lots will be making their purchaser decision in full knowledge of the approved setbacks of the adjoining lots. Furthermore, the maximum length of the garage wall built to the boundary is 6m within a maximum of 15m from the front boundary alignment. The maximum height of the built to boundary wall is 2.7m. Building Height Except for Lots 1-5, 9, 10 & 13 that shall not exceed 1 storey, the maximum building height of 2 storeys and 8 metres applies, in accordance with the Schedule to the Planning Scheme for Noosa Shire shall apply. Estate Sales Office: Any Estate Sales Office or Display Home must comply with the provisions of section 5.14 of the Transitional Planning Scheme for Noosa Shire. Community Use Facilities: Community Use Facilities are to be located in accordance with this Plan of Development and are to be developed generally in Compliant The proposed dwelling is configured over one (1) storey and is below the 8m height limit. Page 10 of 26
Page 11
accordance with the Community Centre proposal plans prepared by AV Jennings Plans SKO1A (Feb 11), SKO2 (Feb 11) & SKO3 (Feb 11). Allotment 61 Key Requirements Group Housing Development Precinct Private Open Space Entry Lots 901/902: e No Dwellings or Structures other than depicted in the approval landscape plan are to be erected or otherwise installed on these lots. e Maintenance agreement to be included in all bodies corporate to ensure ongoing maintenance of entrance features. Group Housing Lots 94 & 99: e Dwelling units within lot 94 & 99, adjacent to the entry road, are to be set back a minimum of 6 metres. Compliant No dwellings or Structures are proposed to be erected on lots 901, 902, 94 & 99 as part of this proposal. General General requirements for all group Housing Development Precinct Residential Lots: All buildings shall be screened where practical to prevent the ingress of mosquitoes and smaller biting midges. Compliant All proposed buildings will be screened where practical. Site Cover The maximum site cover for any lot shall not exceed: e 50% for ground floor; and e 40% for First Floor to achieve a steeping of buildings. Compliant The proposal is configured over one (1) storey and comprises a total site cover of 46.3%, less than the prescribed 50% site cover for the ground floor. Front Setbacks Alllots shall have a minimum front setback of 3 metres, with garages setback a minimum of 4.5m, with minor intrusions permitted of eaves, covered entrances and the like. Where a lesser setback than 5.4m _ is proposed to garages: e Provision shall be given for visitor parking on the driveway with a minimum length of 5.4 metres, measured form the garage and a 3.0 metre separation from the back of kerb to the rear of a parked vehicle maintained. e The sightline requirements to the footpath shall be maintained in accordance with AS2890.1-2004, for vehicles parked on the proposed driveways. e Front and side setbacks are to be Compliant The proposed dwelling is in accordance with requirements and includes a minimum 3m setback measured from the boundary to the front building line and a 4.5m setback from the boundary to the garage. In addition, the provision of a cross over measured approximately 5m from the boundary to the street frontage enables visitor parking on the driveway. We confirm that the proposed garage is setback behind with the main dwelling facade. Page 11 of 26
Page 12
measured from the facade (face of building) to the boundary. Where the boundary alignment is non linear or irregular, for example corner blocks or cul de sac, the setback shall be calculated as an average distance along the length of the facade (face of the building) or garage alignment, which ever applies. Garages shall be setback in line with the main dwelling facade or behind the main dwelling facade. Secondary Frontage (corner allotments) The minimum setback from the secondary street frontage shall be 3.0m. Windows, balconies, verandas and screening devices are to be incorporated into elevations facing street frontages to articulate building form. Laundries and clothes-drying facilities are not to be located along the primary or secondary street frontage, unless suitable screening is provided. Compliant The proposal is not for a corner allotment. Notwithstanding this, the proposal includes perimeter fencing and landscaped treatments. Further, the proposal contains high quality building design and materials to articulate the building form, including the incorporation of screening devices such as aluminium louvers on the building facade, refer to Proposal Plans prepared by AV Jennings located at Appendix A. Rear Setbacks The minimum rear building setback shall be 2metres, with minor intrusions permitted for eaves and the like. Buildings shall be setback a minimum of 6m from the Conservation Parkland boundary, with minor intrusions permitted of eaves and the like. Swimming pools, pergolas, low decks and garden structures shall be setback a minimum of 2m from the Conservation Parkland boundary, with minor intrusions permitted where footings do not adversely impact on vegetation within the Conservation Parkland to the reasonable satisfaction of the Manager Land Use. Compliant The proposal includes a 3m_ setback measured from the rear property boundary to the building line. The proposal is not sited adjacent to or abuts the Conservation Parkland boundary. Built to Boundary Walls and_ Side Setbacks All lots containing built to boundary walls shall provide a minimum side setback of 3m measured for the building fagade to one of the boundaries to ensure open space is maintained between each of the dwelling units. Where no built to boundary walls are identified by the building envelope on the lot, buildings shall be setback a minimum of 1.5m from one side boundary. The maximum length of Built to Boundary walls is 8.0m, built within a maximum of 15m from the front boundary alignment. The maximum height of a built to boundary Compliant A 1.5m side setback is provided to the northern boundary, whist a 6.2m side setback is provided to the southern boundary tapering down to 1.3m at the south-western corner of the site. This is considered to be a minor non- compliance and applies approximately to 1m of the wall length. Page 12 of 26
Page 13
wall is 3.5m and is to be constructed with materials consistent with the remainder of the dwelling. Built to boundary walls are permitted on lots less than 600m2 and all lots which abut conservation parklands. Building Height Except for Lots 1-5, 9, 10 & 13 that shall not exceed 1 storey, the maximum building height of 2 storeys and 8 metres applies, in accordance with the Schedule to the Planning Scheme for Noosa Shire shall apply. Estate Sales Office: Any Estate Sales Office or Display Home must comply with the provisions of section 5.14 of the Transitional Planning Scheme for Noosa Shire. Community Use Facilities: Community Use Facilities are to be located in accordance with this Plan of Development and are to be developed generally in accordance with the Community Centre proposal plans prepared by AV Jennings Plans SKO1A (Feb 11), SKO2 (Feb 11) & SKO3 (Feb 11). Compliant The proposed dwelling is configured over one (1) storey and is below the 8m height limit. Allotment 84 Key Requirements Group Housing Development Precinct Private Open Space Entry Lots 901/902: ¢ No Dwellings or Structures other than depicted in the approval landscape plan are to be erected or otherwise installed on these lots. e Maintenance agreement to be included in all bodies corporate to ensure ongoing maintenance of entrance features. Group Housing Lots 94 & 99: e Dwelling units within lot 94 & 99, adjacent to the entry road, are to be set back a minimum of 6 metres. Compliant No dwellings or Structures are proposed to be erected on lots 901, 902, 94 & 99 as part of this proposal. General General requirements for all group Housing Development Precinct Residential Lots: All buildings shall be screened where practical to prevent the ingress of mosquitoes and smaller biting midges. Compliant All proposed buildings will be screened where practical. Site Cover Compliant Page 13 of 26
Page 14
The maximum site cover for any lot shall not exceed: e 50% for ground floor; and e 40% for First Floor to achieve a steeping of buildings. The proposal is configured over one (1) storey and comprises a total site cover of 50%. Front Setbacks All lots shall have a minimum front setback of 3 metres, with garages setback a minimum of 4.5m, with minor intrusions permitted of eaves, covered entrances and the like. Where a lesser setback than 5.4m _ is proposed to garages: e Provision shall be given for visitor parking on the driveway with a minimum length of 5.4 metres, measured form the garage and a 3.0 metre separation from the back of kerb to the rear of a parked vehicle maintained. e The sightline requirements to the footpath shall be maintained in accordance with AS2890.1-2004, for vehicles parked on the proposed driveways. e Front and side setbacks are to be measured from the facade (face of building) to the boundary. Where the boundary alignment is non linear or irregular, for example corner blocks or cul de sac, the setback shall be calculated as an average distance along the length of the facade (face of the building) or garage alignment, which ever applies. Garages shall be setback in line with the main dwelling facade or behind the main dwelling facade. Compliant The proposed dwelling is in accordance with requirements and includes a 3m _ setback measured from the boundary to the front building line. It is noted that there is adequate space for visitor parking on the driveway without impeding on traffic along Bumpy Ash Lane, which generates minimal traffic movement and services lots 100-102 only. We confirm that the proposed garage is setback in line with the main dwelling facade. Secondary Frontage (corner allotments) The minimum setback from the secondary street frontage shall be 3.0m. Windows, balconies, verandas and screening devices are to be incorporated into elevations facing street frontages to articulate building form. Laundries and clothes-drying facilities are not to be located along the primary or secondary street frontage, unless suitable screening is provided. Compliant The proposal is not for a corner allotment. Notwithstanding this, the proposal includes perimeter fencing and landscaped treatments. Further, the proposal contains high quality building design and materials to articulate the building form, including the incorporation of screening devices such as aluminium louvers on the building facade, refer to Proposal Plans prepared by AV Jennings located at Appendix A. Rear Setbacks The minimum rear building setback shall be 2metres, with minor intrusions permitted for eaves and the like. Buildings shall be setback a minimum of 6m from the Conservation Parkland boundary, with minor intrusions permitted of eaves and the like. Swimming pools, pergolas, low decks and Compliant The proposal includes a 5.9m setback measured from the rear property boundary to the building line. The proposal is not sited adjacent to or abuts the Conservation Parkland boundary. Page 14 of 26
Page 15
garden structures shall be setback a minimum of 2m from the Conservation Parkland boundary, with minor intrusions permitted where footings do not adversely impact on vegetation within the Conservation Parkland to the reasonable satisfaction of the Manager Land Use. Built to Boundary Walls and__ Side Setbacks All lots containing built to boundary walls shall provide a minimum side setback of 3m measured for the building fagade to one of the boundaries to ensure open space is maintained between each of the dwelling units. Where no built to boundary walls are identified by the building envelope on the lot, buildings shall be setback a minimum of 4.5m from one side boundary. The maximum length of Built to Boundary walls is 8.0m, built within a maximum of 15m from the front boundary alignment. The maximum height of a built to boundary wall is 3.5m and is to be constructed with materials consistent with the remainder of the dwelling. Built to boundary walls are permitted on lots less than 600m2 and all lots which abut conservation parklands. Compliant A 1.5m side setback is provided to the southern boundary measured from the boundary to the building line, while a 3.4m side setback is provided to the northern boundary measured from the boundary to the building wall. Building Height Except for Lots 1-5, 9, 10 & 13 that shall not exceed 1 storey, the maximum building height of 2 storeys and 8 metres applies, in accordance with the Schedule to the Planning Scheme for Noosa Shire shall apply. Estate Sales Office: Any Estate Sales Office or Display Home must comply with the provisions of section 5.14 of the Transitional Planning Scheme for Noosa Shire. Community Use Facilities: Community Use Facilities are to be located in accordance with this Plan of Development and are to be developed generally in accordance with the Community Centre proposal plans prepared by AV Jennings Plans SKO1A (Feb 11), SKO2 (Feb 11) & SKO3 (Feb 11). Compliant The proposed dwelling is configured over one (1) storey and is below the 8m height limit. Page 15 of 26
Page 16
Allotment 85 aan Key Requirements Group Housing Development Precinct Private Open Space Entry Lots 901/902: e No Dwellings or Structures other than depicted in the approval landscape plan are to be erected or otherwise installed on these lots. e Maintenance agreement to be included in all bodies corporate to ensure ongoing maintenance of entrance features. Group Housing Lots 94 & 99: « Dwelling units within lot 94 & 99, adjacent fo the entry road, are to be set back a minimum of 6 metres. Compliant No dwellings or Structures are proposed to be erected on lots 901, 902, 94 & 99 as part of this proposal. General General requirements for all group Housing Development Precinct Residential Lots: All buildings shall be screened where practical to prevent the ingress of mosquitoes and smaller biting midges. Compliant All proposed buildings will be screened where practical. Site Cover The maximum site cover for any lot shall not exceed: e 50% for ground floor; and e 40% for First Floor to achieve a steeping of buildings. Compliant The proposal is configured over one (1) storey and comprises a total site cover of 52%, however, a 49% site cover is achieved pursuant to the definition of site cover, which allows for the sala to be measured 600mm in from the perimeter of the roof. Front Setbacks Alllots shall have a minimum front setback of 3 metres, with garages setback a minimum of 4.5m, with minor intrusions permitted of eaves, covered entrances and the like. Where a lesser setback than 5.4m _ is proposed to garages: e Provision shall be given for visitor parking on the driveway with a minimum length of 5.4 metres, measured form the garage and a 3.0 metre separation from the back of kerb to the rear of a parked vehicle maintained. e The sightline requirements to the footpath shall be maintained in accordance with AS2890.1-2004, for vehicles parked on the proposed driveways. e Front and side setbacks are to be measured from the facade (face of building) to the boundary. Where the boundary alignment is non linear Compliant The proposed dwelling is in accordance with requirements and includes a minimum 4m setback measured from the boundary to the front building line and a 5.5m setback from the footpath to the garage. We confirm that the proposed garage is setback behind with the main dwelling facade. Page 16 of 26
Page 17
or irregular, for example corner blocks or cul de sac, the setback shall be calculated as an average distance along the length of the facade (face of the building) or garage alignment, which ever applies. Garages shall be setback in line with the main dwelling facade or behind the main dwelling facade. Secondary Frontage (corner allotments) The minimum setback from the secondary street frontage shall be 3.0m. Windows, balconies, verandas and screening devices are to be incorporated into elevations facing street frontages to articulate building form. Laundries and clothes-drying facilities are not to be located along the primary or secondary street frontage, unless suitable screening is provided. Compliant The proposal is not for a corner allotment. Notwithstanding this, the proposal includes perimeter fencing and landscaped treatments. Further, the proposal contains high quality building design and materials to articulate the building form, including the incorporation of screening devices such as aluminium louvers on the building facade, refer to Proposal Plans prepared by AV Jennings located at Appendix A. Rear Setbacks The minimum rear building setback shall be 2metres, with minor intrusions permitted for eaves and the like. Buildings shall be setback a minimum of 6m from the Conservation Parkland boundary, with minor intrusions permitted of eaves and the like. Swimming pools, pergolas, low decks and garden structures shall be setback a mininum of 2m from the Conservation Parkland boundary, with minor intrusions permitted where footings do not adversely impact on vegetation within the Conservation Parkland to the reasonable satisfaction of the Manager Land Use. Compliant The proposal includes a 3m_ setback measured from the rear property boundary to the building line. The proposal is not sited adjacent to or abuts the Conservation Parkland boundary. Built_ to Boundary Walls _and__ Side Setbacks All lots containing built to boundary walls shall provide a minimum side setback of 3m measured for the building fagade to one of the boundaries to ensure open space is maintained between each of the dwelling units. Where no built to boundary walls are identified by the building envelope on the lot, buildings shall be setback a minimum of 1.5m from one side boundary. The maximum length of Built to Boundary walls is 8.0m, built within a maximum of 15m from the front boundary alignment. The maximum height of a built to boundary wall is 3.5m and is to be constructed with materials consistent with the remainder of the dwelling. Compliant A 3.4m side setback is provided to the northern boundary measured from the boundary to the Sala, while a 1.5m side setback is provided to the southern boundary measured from the boundary to the building wall. Page 17 of 26
Page 18
Built to boundary walls are permitted on lots less than 600m2 and all lots which abut conservation parklands. Building Height Except for Lots 1-5, 9, 10 & 13 that shall not exceed 1 storey, the maximum _ building height of 2 storeys and 8 metres applies, in accordance with the Schedule to the Planning Scheme for Noosa Shire shall apply. Estate Sales Office: Any Estate Sales Office or Display Home Must comply with the provisions of section 5.14 of the Transitional Planning Scheme for Noosa Shire. Community Use Facilities: Community Use Facilities are to be located in accordance with this Plan of Development and are to be developed generally in accordance with the Community Centre proposal plans prepared by AV Jennings Plans SKO1A (Feb 11), SKO2 (Feb 11) & SKO3 (Feb 11). Compliant The proposed dwelling is configured over one (1) storey and is below the 8m height limit. Allotment 86 Key Requirements Group Housing Development Precinct Private Open Space Entry Lots 901/902: e No Dwellings or Structures other than depicted in the approval landscape plan are to be erected or otherwise installed on these lots. e« Maintenance agreement to be included in all bodies corporate to ensure ongoing maintenance of entrance features. Group Housing Lots 94 & 99: e Dwelling units within jot 94 & 99, adjacent to the entry road, are to be set back a minimum of 6 metres. Compliant No dwellings or Structures are proposed to be erected on lots 901, 902, 94 & 99 as part of this proposal. General General requirements for all group Housing Development Precinct Residential Lots: All buildings shall be screened where practical io prevent the ingress of mosquitoes and smaller biting midges. Compliant All proposed buildings will be screened where practical. Site Cover The maximum site cover for any lot shall not exceed: e 50% for ground floor; and e 40% for First Floor to achieve a Compliant The proposal is configured over one (1) storey and comprises a total site cover of 49.6%, less than the prescribed 50% site cover for the ground floor. Page 18 of 26
Page 19
steeping of buildings. Front Setbacks All lots shall have a minimum front setback of 3 metres, with garages setback a minimum of 4.5m, with minor intrusions permitted of eaves, covered entrances and the like. Where a lesser setback than 5.4m is proposed to garages: e Provision shall be given for visitor parking on the driveway with a minimum length of 5.4 metres, measured form the garage and a 3.0 metre separation from the back of kerb to the rear of a parked vehicle maintained. e The sightline requirements to the footpath shall be maintained in accordance with AS2890.1-2004, for vehicles parked on the proposed driveways. e Front and side setbacks are to be measured from the facade (face of building) to the boundary. Where the boundary alignment is non linear or irregular, for example corner blocks or cul de sac, the setback shall be calculated as an average distance along the length of the facade (face of the building) or garage alignment, which ever applies. Garages shall be setback in line with the main dwelling facade or behind the main dwelling facade. Compliant The proposed dwelling is in accordance with requirements and includes a minimum 4m setback measured from the footpath to the front building line, and a 5.5m_ setback measured from the boundary to the garage. We confirm that the proposed garage is setback behind with the main dwelling facade. Secondary Frontage (corner allotments) The minimum setback from the secondary street frontage shall be 3.0m. Windows, balconies, verandas and screening devices are to be incorporated into elevations facing street frontages to articulate building form. Laundries and clothes-drying facilities are not to be located along the primary or secondary street frontage, unless suitable screening is provided. Compliant The proposal is not for a corner allotment. Notwithstanding this, the proposal includes perimeter fencing and landscaped treatments. Further, the proposal contains high quality building design and materials to articulate the building form, including the incorporation of screening devices such as aluminium louvers on the building facade, refer to Proposal Plans prepared by AV Jennings located at Appendix A. Rear Setbacks The minimum rear building setback shall be 2metres, with minor intrusions permitted for eaves and the like. Buildings shall be setback a minimum of 6m from the Conservation Parkland boundary, with minor intrusions permitted of eaves and the like. Swimming pools, pergolas, low decks and garden structures shall be setback a minimum of 2m from the Conservation Parkland boundary, with minor intrusions Compliant The proposal includes a 3.4m_ setback measured from the rear property boundary to the building line. The proposal is not sited adjacent to or abuts the Conservation Parkland boundary. Page 19 of 26
Page 20
permitted where footings do not adversely impact on vegetation within the Conservation Parkland to the reasonable satisfaction of the Manager Land Use. Built to Boundary Walls__and__ Side Setbacks All lots containing built to boundary walls shall provide a minimum side setback of 3m measured for the building fagade to one of the boundaries to ensure open space is maintained between each of the dwelling units. Where no built to boundary walls are identified by the building envelope on the lot, buildings shall be setback a minimum of | 1.5m from one side boundary. The maximum jength of Built to Boundary walls is 8.0m, built within a maximum of 15m from the front boundary alignment. The maximum height of a built to boundary wall is 3.5m and is to be constructed with materials consistent with the remainder of the dwelling. Built to boundary walls are permitted on lots less than 600m2 and all lots which abut conservation parklands. Acceptable Solution It is recognised that built to boundary walls are permitted on lots less than 600m2, and is therefore applicable to this lot. The garage is built to boundary, whilst a 2.6m side setback is provided to the balance of the southern boundary and a 4.9m side setback is provided to the northern boundary. It is noted however that the roof of the sala extends 1.6m into the northern side setback. By definition the sala is permitted to encroach up to 600mm into the side setback. It is our view that the design as submitted achieves an acceptable amenity outcome. Additionally, because each of the houses are clustered together for approval of the designs as submitted, all purchasers of lots will be making their purchaser decision in full knowledge of the approved setbacks of the adjoining lots. Further, the maximum length of the garage wall built to the boundary is 6m within a maximum of 15m from the front boundary alignment. The maximum height of the built to boundary wall is 2.7m. Building Height Except for Lots 1-5, 9, 10 & 13 that shall not exceed 1 storey, the maximum building height of 2 storeys and 8 metres applies, in accordance with the Schedule to the Planning Scheme for Noosa Shire shall apply. Estate Sales Office: Any Estate Sales Office or Display Home must comply with the provisions of section 5.14 of the Transitional Planning Scheme for Noosa Shire. Community Use Facilities: Community Use Facilities are to be located in accordance with this Plan of Development and are to be developed generally in accordance with the Community Centre proposal plans prepared by AV Jennings Plans SKO1A (Feb 11), SKO2 (Feb 11) & SKO3 (Feb 11). Compliant The proposed dwelling is configured over one (1) storey and is below the 8m height limit. Page 20 of 26
Page 21
Allotment 87
Key Requirements
Group Housing Development Precinct
Private Open Space
Entry Lots 907/902:
e No Dwellings or Structures other
than depicted in the approval
landscape plan are to be erected or
otherwise installed on these lots.
e Maintenance agreement to be
included in all bodies corporate to
ensure ongoing maintenance of
entrance features.
Group Housing Lots 94 & 99:
e Dwelling units within lot 94 & 99,
adjacent to the entry road, are to be
set back a minimum of 6 metres.
Compliant
No dwellings or Structures are proposed to be
erected on lots 901, 902, 94 & 99 as part of
this proposal.
General
General requirements for all group Housing
Development Precinct Residential Lots:
All buildings shall be screened where
practical to prevent the ingress of
mosquitoes and smaller biting midges.
Compliant
All proposed buildings will be screened where
practical.
Site Cover
The maximum site cover for any lot shall not
exceed:
e 50% for ground floor; and
e 40% for First Floor to achieve a
steeping of buildings.
Compliant
The proposal is configured over one (1) storey
and comprises a total site cover of 49.5%,
less than the prescribed 50% site cover for
the ground floor.
Front Setbacks
Alllots shall have a minimum front setback of
3 metres, with garages setback a minimum
of 4.5m, with minor intrusions permitted of
eaves, covered entrances and the like.
Where a lesser setback than 5.4m is
proposed to garages:
e Provision shall be given for visitor
parking on the driveway with a
minimum length of 5.4 metres,
measured form the garage and a 3.0
metre separation from the back of
kerb to the rear of a parked vehicle
maintained.
e The sightline requirements to the
footpath shall be maintained in
accordance with AS2890.1-2004, for
vehicles parked on the proposed
driveways.
e Front and side setbacks are to be
measured from the facade (face of
building) to the boundary.
Where the boundary alignment is non linear
or irregular, for example corner blocks or cul
Compliant
The proposed dwelling is in accordance with
requirements and includes a minimum 3m
setback measured from the footpath to the
front building line, and a 4.5m setback
measured from the boundary to the garage.
In addition, the provision of a cross over
measured approximately 7.2m from the
boundary to the street frontage enables visitor
parking on the driveway. We confirm that
the proposed garage is setback behind with
the main dwelling facade.
Page 21 of 26
Page 22
de sac, the setback shall be calculated as an average distance along the length of the facade (face of the building) or garage alignment, which ever applies. Garages shall be setback in line with the main dwelling facade or behind the main dwelling facade. Secondary Frontage (corner allotments) The minimum setback from the secondary street frontage shall be 3.0m. Windows, balconies, verandas and screening devices are to be incorporated into elevations facing street frontages to articulate building form. Laundries and clothes-drying facilities are not to be located along the primary or secondary street frontage, unless suitable screening is provided. Compliant The proposal is not for a corner allotment. Notwithstanding this, the proposal includes perimeter fencing and landscaped treatments. Further, the proposal contains high quality building design and materials to articulate the building form, including the incorporation of screening devices such as aluminium louvers on the building facade, refer to Proposal Plans prepared by AV Jennings located at Appendix A. Rear Setbacks The minimum rear building setback shall be 2metres, with minor intrusions permitted for eaves and the like. Buildings shall be setback a minimum of 6m from the Conservation Parkland boundary, with minor intrusions permitted of eaves and the like. Swimming pools, pergolas, low decks and garden structures shall be setback a minimum of 2m from the Conservation Parkland boundary, with minor intrusions permitted where footings do not adversely impact on vegetation within the Conservation Parkland to the reasonable satisfaction of the Manager Land Use. Compliant The proposal includes a 4m_ setback measured from the rear property boundary to the building line. The proposal is not sited adjacent to or abuts the Conservation Parkland boundary. Built to Boundary Walls _and__ Side Setbacks All lots containing built to boundary walls shall provide a minimum side setback of 3m measured for the building fagade to one of the boundaries to ensure open space is maintained between each of the dwelling units. Where no built to boundary walls are identified by the building envelope on the lot, buildings shall be setback a minimum of 1.5m from one side boundary. The maximum length of Built to Boundary walls is 8.0m, built within a maximum of 15m from the front boundary alignment. The maximum height of a built to boundary wall is 3.5m and is to be constructed with materials consistent with the remainder of the dwelling. Built to boundary walls are permitted on lots Acceptable Solution It is recognised that built to boundary walls are permitted on lots less than 600m2, and is therefore applicable to this lot. The garage is built to boundary, whilst a 2.6m side setback is provided to the balance of the southern boundary and a 4.9m side setback is provided to the northern boundary. It is noted however that the roof of the sala extends 1.6m into the northern side setback. By definition the sala is permitted to encroach up to 600mm into the side setback. It is our view that the design as submitted achieves an acceptable amenity outcome. Additionally, because each of the houses are clustered together for approval of the designs as submitted, all purchasers of lots will be making their purchaser decision in full knowledge of the approved setbacks of the adjoining lots. Page 22 of 26
Page 23
less than 600m2 and all lots which abut conservation parklands. Further, the maximum length of the garage wall built to the boundary is 6m within a maximum of 15m from the front boundary alignment. The maximum height of the built to boundary wall is 2.7m. Building Height Except for Lots 1-5, 9, 10 & 13 that shall not exceed 1 storey, the maximum building height of 2 storeys and 8 metres applies, in accordance with the Schedule to the Planning Scheme for Noosa Shire shall apply. Estate Sales Office: Any Estate Sales Office or Display Home must comply with the provisions of section 5.14 of the Transitional Planning Scheme for Noosa Shire. Community Use Facilities: Community Use Facilities are to be located in accordance with this Plan of Development and are to be developed generally in accordance with the Community Centre proposal plans prepared by AV Jennings Plans SKO1A (Feb 11), SKO2 (Feb 11) & SKO3 (Feb 11). Compliant The proposed dwelling is configured over one (1) storey and is below the 8m height limit. Allotment 88 Key Requirements Group Housing Development Precinct Private Open Space Entry Lots 901/902: e No Dwellings or Structures other than depicted in the approval landscape plan are to be erected or otherwise installed on these lots. e Maintenance agreement to be included in all bodies corporate to ensure ongoing maintenance of entrance features. Group Housing Lots 94 & 99: e Dwelling units within lot 94 & 99, adjacent to the entry road, are to be set back a minimum of 6 metres. Compliant No dwellings or Structures are proposed to be erected on lots 901, 902, 94 & 99 as part of this proposal. General General requirements for all group Housing Development Precinct Residential Lots: All buildings shall be screened where practical to prevent the ingress of mosquitoes and smaller biting midges. Compliant All proposed buildings will be screened where practical. Site Cover The maximum site cover for any lot shall not exceed: Compliant The proposal is configured over one (1) storey and comprises a total site cover of 49.5%, Page 23 of 26
Page 24
e 50% for ground floor; and e 40% for First Floor to achieve a steeping of buildings. less than the prescribed 50% site cover for the ground floor. Front Setbacks All lots shall have a minimum front setback of 3 metres, with garages setback a minimum of 4.5m, with minor intrusions permitted of eaves, covered entrances and the like. Where a lesser setback than 5.4m _ is proposed to garages: e Provision shail be given for visitor parking on the driveway with a minimum length of 5.4 metres, measured form the garage and a 3.0 metre separation from the back of kerb to the rear of a parked vehicle maintained. e The sightline requirements to the footpath shall be maintained in accordance with AS2890.1-2004, for vehicles parked on the proposed driveways. e Front and side setbacks are to be measured from the facade (face of building) to the boundary. Where the boundary alignment is non linear or irregular, for example corner blocks or cul de sac, the setback shall be calculated as an average distance along the length of the facade (face of the building) or garage alignment, which ever applies. Garages shall be setback in line with the main dwelling facade or behind the main dwelling facade. Compliant The proposed dwelling is in accordance with requirements and includes a minimum 3m setback measured from the footpath to the front building line, and a 4.5m _ setback measured from the boundary to the garage. In addition, the provision of a cross over measured approximately 5.2m from the boundary to the street frontage enables visitor parking on the driveway. We confirm that the proposed garage is setback behind with the main dwelling facade. Secondary Frontage (corner allotments) The minimum setback from the secondary street frontage shal! be 3.0m. Windows, balconies, verandas and screening devices are to be incorporated into elevations facing street frontages to articulate building form. Laundries and clothes-drying facilities are not to be located along the primary or secondary street frontage, unless suitable screening is provided. Compliant The proposal is not for a corner allotment. Notwithstanding this, the proposal includes perimeter fencing and landscaped treatments. Further, the proposal contains high quality building design and materials to articulate the building form, including the incorporation of screening devices such as aluminium louvers on the building facade, refer to Proposal Plans prepared by AV Jennings located at Appendix A. Rear Setbacks The minimum rear building setback shall be 2metres, with minor intrusions permitted for eaves and the like. Buildings shall be setback a minimum of 6m from the Conservation Parkland boundary, with minor intrusions permitted of eaves and the like. Swimming pools, pergolas, low decks and garden structures shall be setback a minimum of 2m from the Conservation Compliant The proposal includes a 3.3m_ setback measured from the rear property boundary to the building line. The proposal is not sited adjacent to or abuts the Conservation Parkland boundary. Page 24 of 26
Page 25
Parkland boundary, with minor intrusions permitted where footings do not adversely impact on vegetation within the Conservation Parkland to the reasonable satisfaction of the Manager Land Use. Built to Boundary Walls and _ Side Setbacks All lots containing built to boundary walls shall provide a minimum side setback of 3m measured for the building fagade to one of the boundaries to ensure open space is maintained between each of the dwelling units. Where no built to boundary walls are identified by the building envelope on the lot, buildings shall be setback a minimum of 1.5m from one side boundary. The maximum length of Built to Boundary walls is 8.0m, built within a maximum of 15m from the front boundary alignment. The maximum height of a built to boundary wall is 3.5m and is to be constructed with materials consistent with the remainder of the dwelling. Built to boundary walls are permitted on lots less than 600m2 and all lots which abut conservation parklands. Acceptable Solution It is recognised that built to boundary walls are permitted on lots less than 600m2, and is therefore applicable to this lot. The garage is built to boundary, whilst a 2.6m side setback is provided to the balance of the southern boundary and a 4.9m side setback is provided to the northern boundary. It is noted however that the roof of the sala extends 1.6m into the northern side setback. By definition the sala is permitted to encroach up to 600mm into the side setback. It is our view that the design as submitted achieves an acceptable amenity outcome. Additionally, because each of the houses are clustered together for approval of the designs as submitted, all purchasers of lots will be making their purchaser decision in full knowledge of the approved setbacks of the adjoining lots. Further, the maximum length of the garage wall built to the boundary is 6m within a maximum of 15m from the front boundary alignment. The maximum height of the built to boundary wall is 2.7m. Building Height Except for Lots 1-5, 9, 10 & 13 that shall not exceed 1 storey, the maximum building height of 2 storeys and 8 metres applies, in accordance with the Schedule to the Planning Scheme for Noosa Shire shall apply. Estate Sales Office: Any Estate Sales Office or Display Home must comply with the provisions of section §.14 of the Transitional Planning Scheme for Noosa Shire. Community Use Facilities: Community Use Facilities are to be located in accordance with this Plan of Development and are to be developed generally in accordance with the Community Centre proposal plans prepared by AV Jennings Plans SKO1A (Feb 11), SKO2 (Feb 11) & SKO3 (Feb 11). Compliant The proposed dwelling is configured over one (1) storey and is below the 8m height limit. Page 25 of 26
Page 26
Based on the above, the proposed Detached Houses comply with the relevant Key Development Requirements as indicated on the approved Elysium Master Plan document. 3. CONCLUSION Based on the above assessment, the application complies with the relevant provisions of the approved Elysium Masterplan. We trust that the information submitted is sufficient to enable prompt and favourable assessment. Should you require any further information or wish to discuss any aspect of the proposal, please do not hesitate to contact our office. Yours faithfully RPS McA Mark Farrell General Manager Enc Proposal Plans Cheque IDAS Forms Email correspondence dated 24" April 2013 Lot Calculations Plan Page 26 of 26
Used in these records
Town Planning ReportRelated documentApplication case desk ↗
About this file
- File size
- 1.3 MB (small file)
- File type