garden structures shall be setback a
minimum of 2m from the Conservation
Parkland boundary, with minor intrusions
permitted where footings do not adversely
impact on vegetation within the Conservation
Parkland to the reasonable satisfaction of the
Manager Land Use.

 

Built to Boundary Walls and__ Side
Setbacks

All lots containing built to boundary walls
shall provide a minimum side setback of 3m
measured for the building fagade to one of
the boundaries to ensure open space is
maintained between each of the dwelling
units.

Where no built to boundary walls are
identified by the building envelope on the lot,
buildings shall be setback a minimum of
4.5m from one side boundary.

The maximum length of Built to Boundary
walls is 8.0m, built within a maximum of 15m
from the front boundary alignment.

The maximum height of a built to boundary
wall is 3.5m and is to be constructed with
materials consistent with the remainder of
the dwelling.

Built to boundary walls are permitted on lots
less than 600m2 and all lots which abut
conservation parklands.

Compliant

A 1.5m side setback is provided to the
southern boundary measured from the
boundary to the building line, while a 3.4m
side setback is provided to the northern
boundary measured from the boundary to the
building wall.

 

 

Building Height

Except for Lots 1-5, 9, 10 & 13 that shall not
exceed 1 storey, the maximum building
height of 2 storeys and 8 metres applies, in
accordance with the Schedule to the
Planning Scheme for Noosa Shire shall

apply.

Estate Sales Office:

Any Estate Sales Office or Display Home
must comply with the provisions of section
5.14 of the Transitional Planning Scheme for
Noosa Shire.

Community Use Facilities:

Community Use Facilities are to be located
in accordance with this Plan of Development
and are to be developed generally in
accordance with the Community Centre
proposal plans prepared by AV Jennings
Plans SKO1A (Feb 11), SKO2 (Feb 11) &
SKO3 (Feb 11).

 

Compliant
The proposed dwelling is configured over one

(1) storey and is below the 8m height limit.

 

Page 15 of 26

 

Used in these records

About this file

File size
1.3 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Town Planning Report.pdf · 1.3 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.