Council archive · source document
Town Planning Report · MCU13/0102
de sac, the setback shall be calculated as an average distance along the length of the facade (face of the building) or garage alignment, which ever applies. Garages shall be setback in line with the main dwelling facade or behind the main dwelling facade. Secondary Frontage (corner allotments) The minimum setback from the secondary street frontage shall be 3.0m. Windows, balconies, verandas and screening devices are to be incorporated into elevations facing street frontages to articulate building form. Laundries and clothes-drying facilities are not to be located along the primary or secondary street frontage, unless suitable screening is provided. Compliant The proposal is not for a corner allotment. Notwithstanding this, the proposal includes perimeter fencing and landscaped treatments. Further, the proposal contains high quality building design and materials to articulate the building form, including the incorporation of screening devices such as aluminium louvers on the building facade, refer to Proposal Plans prepared by AV Jennings located at Appendix A. Rear Setbacks The minimum rear building setback shall be 2metres, with minor intrusions permitted for eaves and the like. Buildings shall be setback a minimum of 6m from the Conservation Parkland boundary, with minor intrusions permitted of eaves and the like. Swimming pools, pergolas, low decks and garden structures shall be setback a minimum of 2m from the Conservation Parkland boundary, with minor intrusions permitted where footings do not adversely impact on vegetation within the Conservation Parkland to the reasonable satisfaction of the Manager Land Use. Compliant The proposal includes a 4m_ setback measured from the rear property boundary to the building line. The proposal is not sited adjacent to or abuts the Conservation Parkland boundary. Built to Boundary Walls _and__ Side Setbacks All lots containing built to boundary walls shall provide a minimum side setback of 3m measured for the building fagade to one of the boundaries to ensure open space is maintained between each of the dwelling units. Where no built to boundary walls are identified by the building envelope on the lot, buildings shall be setback a minimum of 1.5m from one side boundary. The maximum length of Built to Boundary walls is 8.0m, built within a maximum of 15m from the front boundary alignment. The maximum height of a built to boundary wall is 3.5m and is to be constructed with materials consistent with the remainder of the dwelling. Built to boundary walls are permitted on lots Acceptable Solution It is recognised that built to boundary walls are permitted on lots less than 600m2, and is therefore applicable to this lot. The garage is built to boundary, whilst a 2.6m side setback is provided to the balance of the southern boundary and a 4.9m side setback is provided to the northern boundary. It is noted however that the roof of the sala extends 1.6m into the northern side setback. By definition the sala is permitted to encroach up to 600mm into the side setback. It is our view that the design as submitted achieves an acceptable amenity outcome. Additionally, because each of the houses are clustered together for approval of the designs as submitted, all purchasers of lots will be making their purchaser decision in full knowledge of the approved setbacks of the adjoining lots. Page 22 of 26
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Town Planning ReportRelated documentApplication case desk ↗
About this file
- File size
- 1.3 MB (small file)
- File type
No other editions are linked here.