Council archive · source document
Apdx 1 - Proposal Plans · MCU24/0001
Plans and drawings: the text below has words only, no drawings.
Original PDF page 12, section 1. The text section number identifies this passage in the reader.
MS1 - Colorbond Custom Orb roof sheeting
fixed to manufacturers specification LINE OF 8.0M BUILDING
for required wind category. (25° pitch). ENVELOPE FROM EXISTING NGL.
450 Eave Prefabricated pine roof trusses
Timber pergola structure at 900 crs. Roof Bracing to truss
to engineers specification manufacturers specification.
200 series blockwork wall 450 Eave Colorbond slotted gutter, fascia to match
with stone cladding roofing. Fix to manufacturers specification.
to engineers detail. (Nom. 150 Skyline Gutter)
CL
JL Gyprock wall &
ceiling linings.
2700
Wall Framing to
ROBE
2400
Bed 2 Bed 3
engineers specification.
FL
Floor framing to engineers
CL
detail. Provide drop joists to
JL wet areas as required.
2700
2400
Dining Kitchen
FL
Pool
Reinforced footing & slab
Section 1 to engineers details.
Scale : 1 : 100 Compacted fill to engineers detail.
Concrete pool shell
to engineers detail. LINE OF 8.0M BUILDING
ENVELOPE FROM EXISTING NGL. Prefabricated pine roof trusses
450 Eave at 900 crs. Roof Bracing to truss
manufacturers specification.
Timber pergola structure
450 Eave
to engineers specification Colorbond slotted gutter, fascia to match
roofing. Fix to manufacturers specification.
200 series blockwork wall
(Nom. 150 Skyline Gutter)
with stone cladding
C:\Users\phil\qldBUILT Dropbox\qldBUILT Design (phil)\2 Jan St\1-PRE CON\3 - Architectural Design\8 - Revit Files\2 Jan Street - revised concept design G.rvt
CL to engineers detail.
JL Gyprock wall &
ceiling linings.
2700
2400
Wall Framing to
engineers specification.
FL
Floor framing to engineers
CL
detail. Provide drop joists to
JL wet areas as required.
2700
2400
Entry
FL
Reinforced footing & slab
to engineers details.
Section 2 Approx. Line of Existing Ground Compacted fill to engineers detail.
The drawing and the design depicted on this sheet remains the property of qldBUILT. Reproduction in part or whole is prohibited
Scale : 1 : 100 C COPYRIGHT unless written permission is obtained from qldBUILT. Plans are designed for use on the job address specified in the titleblock only.
DIRECTOR : DESIGN TEAM : PROJECT ADDRESS : PROJECT REVISION SCHEDULE DATE : 18/12/23 A3
Aaron Waters STATUS: Developed Drawings - C Number Description Date Issued by
Dominic Tyacke
E : [email protected] E : [email protected] 2 Jan Street 4 Section & plan
updates
01/12/23 PD
PROJECT NUMBER: SHEET NUMBER:
M : 0410 332 167 CLIENT :
Q.B.C.C LICENCE NO. : 15035880 QLDBUILT PTY LTD
W: www.qldbuilt.com.au
Phil Darwen
E : [email protected]
Noosa Heads Venter, Greg & Keri 5 Amendments to FFL's 18/12 PD
23-007 09
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Apdx 1 - Proposal Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.