Log in to see the plans as drawn RL 9.904 m RL 9.904 m Timber gable detailing to builders detail.
300 600 600 600
600 600 600 600
Colorbond Custom orb roof sheeting
Selected Lineaboard (Or similar) cladding fixed to manufacturers specification
fixed to manufacturers specification. for N3 wind category. (20° pitch).
Select feature driveway entry Aluminum framed windows
Ceiling Height
gate to manufacturers detail. to manufacturers specification.
2550
Joinery
2100
600 600 300 600 Select window trim extrusion Phone: 0488209840
600 600 600 600 600 to builders detail.
600 email:
[email protected]
1904 - Wall
website: www.iconbuildingdesign.com.au
3088 - Height to F.G.L.
3800 - Height to N.G.L.
Ceiling Height
Approx. At Wall Face
Verify
Verify
2700
Joinery
2400
800
Rendered blockwork retaining wall to
engineers detail with select timber picket
fence over to builders detail. To be Pool
fence compliant where applicable.
Timber framed pergola feature to
STREET FRONT ELEVATION builders detail. T.B.C.
450 600 600 600 600 450
Aluminum framed windows
to manufacturers specification. Select window trim extrusion to
RL 9.904 m builders detail.
RL 9.611 m
Colorbond Custom orb roof sheeting
fixed to manufacturers specification
for N3 wind category. (20° pitch).
Ceiling Height
600
2550
Joinery
2100
600 Timber framed pergola feature to
builders detail. T.B.C.
600 600 600
600
Ceiling Height
2700
Joinery
2400
No. Description Date
Approx.
657
800
Rendered blockwork retaining wall to Approx. Proposed Ground Line A Initial Development Ass. 06/07/2017
engineers detail with select timber picket
fence over to builders detail. To be Pool
B Alternate Option 10/07/2017
Approx. Natural Ground Line
fence compliant where applicable. C Initial Concept 12/09/2017
Selected Lineaboard (Or similar) cladding
ELEVATION 2 D 3D Perspectives 22/09/2017
fixed to manufacturers specification.
E Elevations 22/09/2017
F Combined 03/10/2017
Timber gable detailing to builders detail.
600 600 600 300 600 600 600 600 G D.A. Set 1.0 20/10/2017
Colorbond Custom orb roof sheeting
fixed to manufacturers specification
H D.A. Set 2.0 29/11/2017
for N3 wind category. (20° pitch). I D.A. Set 3.0 02/02/2018
Aluminum framed windows J D.A. Set 3.1 08/02/2018
to manufacturers specification. K D.A. Set 3.2 16/02/2018
Selected Lineaboard (Or similar) cladding 600 300 L D.A. Set 3.3 13/03/2018
Ceiling Height
fixed to manufacturers specification.
7204 - Build Height From F.G.L.
M D.A. Set 3.4 28/03/2018
2550
600 600
Joinery
2100
600 600 600
600 N D.A. Set 3.5 06/04/2018
600 600
Verify
Selected french doors to
Ceiling Height
manufacturers specifications.
2700
Joinery
2400
Select window trim extrusion
to builders detail.
514
533
605
697
697
Select pergola feature to builders
specifications. (TBC)
The Property
Clinic
ELEVATION 3
450 600 600 600 600 450
Aluminum framed windows
to manufacturers specification.
Timber gable detailing to builders detail.
No. 30 & 32 The
Colorbond Custom orb roof sheeting
fixed to manufacturers specification
Cockleshell,
for N3 wind category. (20° pitch).
Noosaville
Ceiling Height
600 600
2550
600
Joinery
600
2100
Max Building Height From N.G.L
600 600 Elevations
7998 - Approx.
600 600
Project number 17-044
Ceiling Height
2700
Joinery
2400
Date 06/04/2018
1500
Drawn by
Aaron Waters
867
900
Approx. Proposed Ground Line
Selected Lineaboard (Or similar) cladding
Checked by Bradley Hunt
6/04/2018 2:29:55 PM
fixed to manufacturers specification.
Approx. Natural Ground Line
Selected panel lift door fixed to
manufacturers specification.
Select window trim extrusion
ELEVATION 4
to builders detail.
05
Scale 1 : 100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.