Council archive · source document
Driveway Crossover 291116 · OPW16/0270
Attached to the e-mail OPW16/0270 email from applicant with information response attached.msg.
MEMBER SCHEDULE AND NOTES
DESIGN WIND SPEED = WIND CLASSIFICATION N3 - AS4055.
ALL TIMBER EXPOSED TO THE WEATHER TO BE DURABILITY CLASS 2 OR BETTER.
LAMBEAMS € LVL's EXPOSED TO THE WEATHER ARE TO BE PROTECTED IN ACCORDANCE
WITH MANUFACTURERS SPECIFICATIONS.
TIEDOWN ENDS OF ALL LINTELS AND ROOF BEAMS WITH |/MI2 ANCHOR ROD, UNO.
ALL MEMBERS NOTED AS H3 TREATED ARE TO BE H3 TRU-CORE TREATED,
WALL FRAMING
STUDS - 90x35 MGPI2 STUDS @450 CRS MAX NOT NOTCHED.
TOP PLATE - 2/90x35 MGPI2. TIEDOWN WITH MI2 ANCHOR RODS AT ENDS AND @1800
CRS MAX FOR ROOF SPANS UP TO 4.3m AND @1200 CRS MAX FOR ROOF SPANS UP TO
7.2m,
BOTTOM PLATE - 90x35 MGPI2, STUDS TO BE IN LINE WITH JOISTS OR PROVIDE
SOLID NOGGING IN BETWEEN FOR SUPPORT,
STUDS BESIDE OPENINGS 0 - 2600 2 STUDS
2600 - 4300 3 STUDS
4300 - 4500 4 STUDS
>4500 - 75x75x4.0 SHS,
BATTENS (METAL ROOF) - 38x75 FIl @900 CRS MAX. 1/75mm No 14 TYPE |7 SCREW
TO EACH RAFTER / TRUSS.
GT - GIRDER TRUSS,
HT - HIP TRUSS,
JT - JACK TRUSSES @900 CRS MAX TO TRUSS MANUFACTURER'S SPECIFICATIONS.
T - TRUSSES @900 CRS MAX TO TRUSS MANUFACTURERS SPECIFICATIONS,
BUILDER TO SUBMIT TRUSS LAYOUT TO ENGINEER FOR CONFIRMATION OF LINTEL SIZES,
ETC,
Bl - 240x63 HYSPAN BEARER IN PLANE OF JOISTS. JOIST HANGERS TO JOISTS IN
ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS.
B2 - 240x85 2IC LAMBEAM CONT SPAN,
B3 - 300x63 HYSPAN H3 TREATED CONT SPAN WHERE POSSIBLE.
B4 - 120x65 2IC LAMBEAM.
Bs - [50x75 Fl4 BEARER IN PLANE OF JOISTS, JOIST HANGERS TO EACH JOIST,
Bo - 125x75 Fl4.
B7 - 225x75 Fl4,
Be - 175x75 Fl4,
Ba - 150x75 Fl4.
BIO - 240x63 HYSPAN CONT SPAN H3 TREATED.
Cl - 89x89x3.5 SHS COLUMN. C2 - 89x89x3.5 SHS COLUMN.
ET - EDGE THICKENING.
DOUBLE JOISTS UNDER ALL LOADBEARING WALLS, UNO.
DJ - DOUBLE JOISTS.
Ji - HJ24090 HYJOIST | BEAM JOISTS @450mm CRS CONT SPAN WHERE POSSIBLE TO
BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS.
JIA - 240x45 HYSPAN JOISTS CONT SPAN WHERE POSSIBLE.
J2 - 240x45 HYSPAN JOISTS CONT SPAN @450mm CRS MAX.
J3 - 175x50 Fl4 JOISTS @450mm CRS MAX,
J4 - 150x50 Fl4 JOISTS @300mm CRS MAX,
J5 - 150x50 Fl4 JOISTS @450mm CRS MAX,
Jé - 125x50 FI4 JOISTS @450mm CRS MAX,
J7 - HJ24045 HYJOIST | BEAM JOISTS @450mm CRS MAX, CONT SPAN.
J8 - 175x50 Fl4 JOISTS @300mm CRS MAX.
ALL LINTELS ARE HYSPAN, UNO,
LI - DOUBLE TOP PLATE. L2 - 90x63 L3 - [30x63 L4 - 150x63
L5 - (70x63 L@ - 200x63 L7 - 240x63 L8 - 300x63
Pl - 89x89x3,5 SHS POST,
P2 - 125x125 HWD POST.
PPI - 150x45 HYSPAN POLE PLATE IN PLANE OF RAFTERS/TRUSSES 2Nol4 BATTEN
SCREWS TO EACH STUD (ie. @450mm CRS) MIN 50mm PENETRATION INTO
PREDRILLED HOLES IN STUDS TO AVOID SPLITTING.
PP2 - 125x50 FI4 POLE PLATE, MI2 CHEMICAL ANCHORS TO BLOCK WALL AT ENDS AND
@450mm CRS MAX.
RI - 150x45 HYSPAN RAFTERS @900mm CRS MAX. | FRAMING ANCHOR EACH SUPPORT.
R2 - 170x45 HYSPAN RAFTERS @900mm CRS MAX, | FRAMING ANCHOR EACH SUPPORT.
RBI - [30x65 17C LAMBEAM H3 TREATED,
RB2 - 245x85 |7C LAMBEAM.
RB3 - 195x85 17C LAMBEAM.
RB4 - 195x85 17C LAMBEAM.
RBS - 195x85 17C LAMBEAM.
ULI - [50x63 HYSPAN UPPER LEVEL LINTEL TO 3/2400 WIDE WINDOWS WITH MIN 2
STUDS BETWEEN WINDOWS # MI2 ANCHOR ROD BETWEEN STUDS,
UL2 - 150x63 HYSPAN UPPER LEVEL LINTEL TO 2700 MAX WIDE UPPER LEVEL LINTEL.
AT ENDS.
L_
ROOF FRAMING PLAN
GALV STRAP BRACING NAILED TO TOP
OF EACH RAFTER/TRUSS AND LOOPED
RIENMAC eryit
A.BN. 52 010 666 430 A.C.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS
SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO, F
[37 BRISBANE ROAD,
(PO BOx |44)
P:- (07) 5478 250
(07) 5444 |I5q
- info@rienmac,biz
info@rienmac,ne'
MOOLOOLABA QLD 4557 Web:— www ,rienmac, bi:
CLIENT:
GREEN EARTH HOMES
PROJECT:
PROPOSED RESIDENCE
22 LITTLE COVE ROAD
NOOSA HEADS QLD 4567
REAL PROPERTY DESCRIPTION ¢ COUNCIL:
LOT 52, RP 52418
PARISH OF WEYBA, COUNTY OF MARCH
NOOSA SHIRE COUNCIL
DRAWING TITLE:
ROOF FRAMING PLAN
MEMBERS SCHEDULE
Designed: PLR Drawn:
LR
SCALES: 1:100
Engineer: PLR |DATE: 7 OCT |é
6427 | S4
C
PETER RIENECKER - RPEQ 2088
Fea ee Bienes CeetieG Paros tot written | JOB NUMBER DWG No. | ISSUE
DO NOT SCALE OFF DRAWINGS. | AS |SHEET 4 OF 12 |CHECKED: PLR