Council archive · source document
IDSA Form 6 Sept · OPW16/0221
Attached to the e-mail Operational Works Application.msg OPW16/0221.
Department of Infrastructure, Local Government and Planning A statement about how the proposed development addresses the local EL] Confirmed government's planning schemes and any other planning documents relevant to the application. A statement addressing the relevant part(s) of the State Development EL Confirmed Assessment Provisions (SDAP). Chet applicable Applications for building work (including extensions and demolition that is assessable development) Floor plans drawn to an appropriate scale (1:50, 1:100 or 1:200 are [_] Confirmed recommended scales) which show the following: Not applicable e the north point e the intended use of each area on the floor plan (for commercial, industrial or mixed use developments only) e the room layout (for residential development only) with all rooms clearly labelled e the existing and the proposed built form (for extensions only) e the gross floor area of each proposed floor area. Elevations drawn to an appropriate scale (1:100, 1:200 or 1:500 are L] ‘onfirmed recommended scales) which show plans of all building elevations and Not applicable facades, clearly labelled to identify orientation (e.g. north elevation). Plans showing the size, location, proposed site cover, proposed maximum [A Confirmed number of storeys, and proposed maximum height above natural ground level Not applicabl of the proposed new building work. U pricans Plans showing the extent of any demolition that is assessable development. [Confirmed L Not applicable Applications for operational work involving earthworks (filling and excavating) Drawings showing: L_] Confirmed e existing and proposed contours [Not applicable © areas to be cut and filled e the location and level of any permanent survey marks or reference stations used as datum for the works e the location of any proposed retaining walls on the relevant land and their height e the defined flood level (if applicable) e the fill level (if applicable). Applications for operational work involving roadworks Drawings showing: | Confirmed e existing and proposed contours Not applicable e the centreline or construction line showing chainages, bearings, offsets if the construction line is not the centreline of the road and all intersection points e information for each curve including tangent point chainages and offsets, curve radii, arc length, tangent length, superelevation (if applicable) and curve widening (if applicable) e kerb lines including kerb radii (where not parallel to centreline) and tangent point changes (where not parallel to centreline) ® edge of pavement where kerb is not constructed position and extent of channelisation location and details of all traffic signs, guideposts, guardrail and other street furniture e pavement markings including details on raised pavement markers IDAS form 6-——-Building or operational work assessable against a planning é Version 3.1—3 Augt
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
IDSA Form 6 Sept.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.