App C - Current Decision Notice and Approved Plans
♻ play your part - print on recycled paper
5m 4 3 2 1
-
APPROVED PLAN
MCU25/0057,OPW25/0078
& RAL25/0010
COLORBOND® steel Custom Orb oof sheeting to be fixed in NOOSA COUNCIL
accordance with manufacturers specifications. 15 SEP 2025
Timber framed walls to be constructed in accordance with structural
engineers design and detail. Walls to have Hebel wall panels finished
with acrylic render system with fine sand finish and painted.
STRATCO 200mm Edge gutters in COLORBOND® steel to be
fixed in accordance with manufacturers specifications. 180 x
Powdercoated aluminium framed screen with 25 x 25mm Hinoki 30mm h3 treated primed timber fascia. Gutters to have 10mm
Knotwood aluminium battens to each side of frame to form privacy spacers to fascia to provide overflow point.
screen.
8,605
Ceiling
Fabriacted Powdercoated aluminium 50 x 10mm bars
@ 100mm cts. with 70 x 10mm top rail to provide
Noosa Council
2,700
balustrade in accordance with ABCB Housing Timber framed walls to be constructed in accordance Annotation
Provisions Standard 2022 : 11.3. Balustrade to be a with structural engineers design and detail. Walls to
min. 1000mm high above finished floor level. have Hebel wall panels finished with acrylic render
Refer to
5,905 5,905 5,905 system with fine sand finish and painted. Conditions 16
First floor and 17 of the
Decision Notice
4,450 regarding front
3,205
4,050 fence design and
3,650
the combined
height of
2,700 retaining walls
Ground floor
and fences within
1,650 Concrete block wall to be in
Knotwood Hinoki aluminium battens to form fence/gate. Battens to be accordance with structural 6 metres of the
100 x 25mm sections (125mm max. spacing typical) to have engineers design and detail. front boundary.
concealed fixings in accordance with manufacturers specifications. Provide Crackenback stone facing
Panels to be self-supported with 12mm threaded rods & 20mm by Eco outdoor.
Powdercoated aluminium spacer set down 300mm from top of
battens. Modinex Beachclad Channel (Mist) bandsawn cladding installed in
accordance with manufacturers specifications.
Double CHS steel column (hdg) to be in accordance with structural
engineers design and detail.
Southern Elevation
S 1:100
/Users/benthornton/Documents/Cadfiles/2503 - Palazzesi - 9 George/Archicad/
09072025/2503.pln
sbt designs pty ltd t/a
Skale Building Design project Duplex lot no. 8 DA06 Development application issue 9/7/2025
project number
Mobile: 0412 025 657
for Ross Palazzesi plan no. RP72243 DA05 Development application issue 30/6/2025
2503
skale skale.com.au
DA04 Development application issue 25/6/2025
9 George Street drawn BT
DA03 Development application issue 24/6/2025
drawing number
[email protected]
building
Document Set design
ID: 23937839A.C.N. 123 976 296 QBCC: 1143 609 at Noosaville scale (A3) 1:100 Rev Details Date 10 DA06 © Skale Building Design
Version: 1, Version Date: 16/07/2025