C04-SEWERAGE-LONGITUDINAL-SECTION-Rev.1
MAINTENANCE HOLE / SHAFT No. D EXISTING SEWER M/H cb NEW SEWER M/H PROPERTY BOUNDARY cD MH / MS COVER TYPE (a) Ne MH / MS TYPE uv BRO BRANCH DROP TYPE > PROPERTY CONNECTION TYPE EXISTING SEWER PIPE DATUM 69.00 RW PROPERTY CONNECTION GZ PROP. DESCRIPTION FP ROAD PIPE NOMINAL DIAMETER (DN) TYPE, CLASS DN 150 PVC SN8 DN 150 PVC SN8 GRADE (1 IN xX) 20 87 LENGTH 61690 21774 DEPTH OF INVERT BELOW F.S.L. 1.320 1.250 2.90 INVERT LEVEL (IL) 69.43 69.50 72.25 FINISHED SURFACE LEVEL (FSL) 70.75 75.15 EXISTING SURFACE LEVEL (ESL) 70.75 CHAINAGE 0.00 61.690 | 75.15 LONGITUDINAL SECTION SCALE: 1:250 HORIZONTAL 1:125 VERTICAL UW_AND CONTRACTOR LIVE SEWER WORKS 1. EXCAVATION WORKS CARRIED OUT BY CONTRACTORS AT A DEPTH OF 1.5m OR GREATER MUST PROVIVE A’ SAFE WORK PLAN ’ AS PER WORKPLACE HEALTH AND SAFETY LEGISLATION TO COUNCIL COMMENCING ANY WORK 2. IT IS THE DEVELOPERS RESPONSIBILITY TO ENSURE ALL LIVE SEWER WORKS ARE COMPLETED BEFORE ALLOWING PRIVATE DRAINAGE TO BE CONNECTED 72.50 75.20 83.465 75.20 GENERAL NOTES : 1. 10. 11. 12. 13. 14, ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH CURRENT SOUTH EAST QUEENSLAND SEWERAGE CODE SPECIFICATIONS AND STANDARDS. . UNLESS SPECIFIED OTHERWISE ALL MATERIALS AND WORK SHALL COMPLY WITH THE RELEVANT AUSTRALIAN STANDARDS. . THE CONSTRUCTION OF THE SEWERAGE WORK SHOWN ON THIS DRAWING SHALL BE SUPERVISED BY AN ENGINEER WHO HAS RPEQ REGISTRATION. SEWERAGE WORKS NOT COMPLYING WITH THIS REQUIREMENT WILL NOT BE PERMITTED TO CONNECT INTO THE SEQ SERVICE PROVIDER SEWERAGE SYSTEM. . ALL WORK ASSOCIATED WITH LIVE SEWERS OR MAINTENANCE HOLES SHALL BE CARRIED OUT BY THE SEQ SERVICE PROVIDER AT THE DEVELOPER'S COST. . ALL PIPES AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE "ACCEPTED PRODUCTS AND MATERIALS” LIST. . EACH ALLOTMENT SHALL BE SERVED BY A DN110 PE (OR DN100 PVC) PROPERTY CONNECTION. FOR ALLOTMENTS OTHER THAN SINGLE RESIDENTIAL, A DN160 PE (OR DN150 PVC) PROPERTY CONNECTION SHALL BE PROVIDED. . PROPERTY CONNECTIONS SHALL BE LOCATED WITHIN THE PROPERTY AS SHOWN IN THE DRAWINGS. . PROPERTY CONNECTION BRANCHES SHALL EXTEND INTO THE PROPERTY A MINIMUM OF 300mm AND A MAXIMUM OF 750mm. UNITYWATER REQUIRES MINIMUM EXTENSION OF 500mm INTO PROPERTY. . WHERE PIPES ARE LAID IN FILL, THE FILLING SHALL BE CARRIED OUT IN LAYERS NOT EXCEEDING 300mm (LOOSE) IN DEPTH AND SHALL BE COMPACTED UNTIL THE COMPACTION IS NOT LESS THAN 95% OF THE MATERIALS MAXIMUM COMPACTION WHEN TESTED IN ACCORDANCE WITH A.S. 1289 (MODIFIED COMPACTION). TESTING SHALL BE CARRIED OUT AFTER EACH ALTERNATE LAYER. IN ALL SUCH CASES APPROVAL OF CONSTRUCTED SEWERS WILL NOT BE ISSUED BY THE SEQ SERVICE PROVIDER UNLESS CERTIFICATES ARE PRODUCED CERTIFYING THAT THE REQUIRED COMPACTION HAS BEEN ACHIEVED. WHERE SEWERS HAVE A GRADE OF 1 IN 20 OR STEEPER, BULKHEADS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE SEQ SEWER CODE. THE CONTRACTOR SHALL VERIFY THE LOCATION AND DEPTH OF EXISTING SERVICES WITH RELEVANT AUTHORITIES BEFORE COMMENCING WORKS. SEWERS SHALL BE DISUSED /ABANDONED IN ACCORDANCE WITH PROCEDURES SET OUT IN THE SEQ SEWER CODE. BENCH MARK AND LEVELS TO AHD. EXISTING ALLOTMENTS REQUIRING A PROPERTY CONNECTION FROM EXISTING SEWERS SHALL BE PROVIDED BY THE SEQ SERVICE PROVIDER AT THE DEVELOPERS COST. ENVIRONMENTAL CONDITIONS : PLACE ON YOUR DRAWING NOTES AS RECEIVED IN YOUR APPROVAL LETTER FROM THE ENVIRONMENTAL REGULATOR OR MANAGER. IF NOTES RELEVANT TO THIS ESTATE ARE NOT SPECIFIED IN YOUR APPROVAL LETTER, TYPICAL NOTES AS FOLLOWS SHALL BE PLACED ON ALL DRAWINGS. VEGETATION PROTECTION : A. TREES LOCATED ALONG THE FOOTPATH SHALL BE, TRANSPLANTED PRIOR 10 CONSTRUCTION, OR REPLACED IF DESTROYED. B. WHEN WORKING WITHIN 4m OF TREES, RUBBER OR HARDWOOD GIRDLES SHALL BE CONSTRUCTED WITH 1.8m BATTENS CLOSELY SPACED AND ARRANGED VERTICALLY FROM GROUND LEVEL. GIRDLES SHALL BE STRAPPED TO TREES PRIOR TO CONSTRUCTION AND REMAIN UNTIL COMPLETION. C. TREE ROOTS SHALL BE TUNNELLED UNDER, RATHER THAN SEVERED. IF ROOTS ARE SEVERED THE DAMAGED AREA SHALL BE TREATED WITH A SUITABLE FUNGICIDE. CONTACT RELEVANT COUNCIL ARBORIST FOR FURTHER ADVICE. D. ANY TREE LOPPING REQUIRED SHOULD BE UNDERTAKEN BY AN APPROVED ARBORIST. SOIL: . TOPSOIL AND SUBSOIL SHALL BE STOCKPILED SEPARATELY. A B. CARE SHALL BE TAKEN TO PREVENT SEDIMENT FROM ENTERING THE STORMWATER SYSTEM. THIS MAY INVOLVE PLACING APPROPRIATE SEDIMENT CONTROLS AROUND STOCKPILES. C. ACID SULPHATE SOILS EXIST IN THE WORKS AREA. THE OUTPUTS FROM THE RISK ASSESSMENT BASED ON THE QUEENSLAND ACID SULPHATE SOIL TECHNICAL MANUAL REQUIRES THAT ACID SULPHATE SOILS BE MANAGED AS FOLLOWS: (DELETE IF NO ACID SULPHATE SOILS) CREEK CROSSINGS : A. SILTATION CONTROL MEASURES SHALL BE PLACED DOWNSTREAM OF ANY EXCAVATION WORK. B. APPROPRIATE SEDIMENT CONTROLS SHALL BE USED TO PREVENT SEDIMENT FROM ENTERING THE CREEK. C. NO SOIL SHALL BE STOCKPILED WITHIN Sm OF THE CREEK. REHABILITATION: A. PREDISTURBANCE SOIL PROFILES AND COMPACTION LEVELS SHALL BE REINSTATED. B. PREDISTURBANCE VEGETATION PATTERNS SHALL BE RESTORED. SAFELY : A. THE DESIGN AND CONSTRUCTION OF THE WORKS SHALL COMPLY WITH ALL QUEENSLAND LEGISLATION ALL ENVIRONMENT PROTECTION MEASURES SHOULD BE IMPLEMENTED PRIOR TO ANY CONSTRUCTION WORK, INCLUDING CLEARING, COMMENCING. No. DESCRIPTION DIA. SEWER] MH/MS]MH/MS|CoveR] Lor | FSL | ESL | Ut. | DEPTH No. } TYPE | TYPE | No. TO. INVERT 1 (A) | UNITYWATER TO BREAK INTO EXISITING MAINTENANCE HOLE 1/1 150 it P2 70.75 | 70.75 | 69.50 | 1.250 AND CONSTRUCT 150mm STUB (TEMPORARILY END CAPPED) PRIOR TO START OF CONSTRUCTION 1 (B) | CONTRACTOR TO LAY NEW LINE 1 AND INSTALL PROPERTY 150 afi | P2 75.15 | 7515 | 72.25 | 2.90 CONNECTION E/' 150 75.20 | 75.20 | 7250 | 270 1 (C) | UNITYWATER TO REMOVE TEMPORARY END CAPS ON STUB AND MAKE LIVE CONNECTION AFTER SUCCESSFUL "ON MAINTENANCE” INSPECTION. APPROVED SCALE AS SHOWN | JOB DESCRIPTION DRAWING TITLE _—_— NEIL McKENZIE & ASSOCIATES PTY. LTD. DRAWN 1 NOOSA YOUNGCARE SEWERAGE LONGITUDINAL SECTION CONS ULTI ENGINEERS CHECKED NN 32 VIEWLAND DRIVE 40921 | a VIEWS, REE 2087, NPER 3 14/699a SANDGATE ROAD DESIGNED NM NOOSA HEADS A o8oa.2t | ———— CLAYFIELD, QLD 4011 APPROVED 1 CLIENT 6 — THIS DRAWING REMAINS THE PROPERTY OF PHONE: (07) 3862 1886 DRAWIN' REVISION No. REVISION DATE DWN | NEIL McKENZIE & ASSOCIATES (C) Copyright FAX: oy 3862 1397 DATE OCT. 20 DELUCA DEVELOPMENT & CONSTRUCTION NUMBER Q20-004-C04 NUMBER |
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.